Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/24064
Title: Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study
Authors: de Jong, Joost J. A.
Lataster, Arno
van Rietbergen, Bert
Arts, Jacobus J.
GEUSENS, Piet 
VAN DEN BERGH, Joop 
Willems, Paul C.
Issue Date: 2017
Publisher: BIOMED CENTRAL LTD
Source: BMC MEDICAL IMAGING, 17, p. 1-7 (Art N° 18)
Abstract: Background: Carbon-fiber-reinforced poly-ether-ether-ketone (CFR-PEEK) has superior radiolucency compared to other orthopedic implant materials, e.g. titanium or stainless steel, thus allowing metal-artifact-free postoperative monitoring by computed tomography (CT). Recently, high-resolution peripheral quantitative CT (HRpQCT) proved to be a promising technique to monitor the recovery of volumetric bone mineral density (vBMD), micro-architecture and biomechanical parameters in stable conservatively treated distal radius fractures. When using HRpQCT to monitor unstable distal radius fractures that require volar distal radius plating for fixation, radiolucent CFR-PEEK plates may be a better alternative to currently used titanium plates to allow for reliable assessment. In this pilot study, we assessed the effect of a volar distal radius plate made from CFR-PEEK on bone parameters obtained from HRpQCT in comparison to two titanium plates. Methods: Plates were instrumented in separate cadaveric human fore-arms (n = 3). After instrumentation and after removal of the plates duplicate HRpQCT scans were made of the region covered by the plate. HRpQCT images were visually checked for artifacts. vBMD, micro-architectural and biomechanical parameters were calculated, and compared between the uninstrumented and instrumented radii. Results: No visible image artifacts were observed in the CFR-PEEK plate instrumented radius, and errors in bone parameters ranged from -3.2 to 2.6%. In the radii instrumented with the titanium plates, severe image artifacts were observed and errors in bone parameters ranged between -30.2 and 67.0%. Conclusions: We recommend using CFR-PEEK plates in longitudinal in vivo studies that monitor the healing process of unstable distal radius fractures treated operatively by plating or bone graft ingrowth.
Notes: [de Jong, Joost J. A.; van den Bergh, Joop P. W.] Maastricht Univ, NUTRIM Sch Nutr & Translat Res Metab, Maastricht, Netherlands. [de Jong, Joost J. A.; Geusens, Piet P.; van den Bergh, Joop P. W.] Maastricht Univ, Dept Rheumatol, Med Ctr, Maastricht, Netherlands. [Lataster, Arno] Maastricht Univ, Dept Anat & Embryol, Maastricht, Netherlands. [van Rietbergen, Bert; Arts, Jacobus J.] Eindhoven Univ Technol, Fac Biomed Engn, Eindhoven, Netherlands. [Arts, Jacobus J.; Willems, Paul C.] Maastricht Univ, Dept Orthoped Surg, Med Ctr, Maastricht, Netherlands. [Arts, Jacobus J.; Geusens, Piet P.; Willems, Paul C.] Maastricht Univ, CAPHRI Sch Publ Hlth & Primary Care, Maastricht, Netherlands. [Geusens, Piet P.; van den Bergh, Joop P. W.] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium. [van den Bergh, Joop P. W.] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands.
Keywords: Injury/fracture healing; HRpQCT; Implant; Distal radius; CFR-PEEK;injury/fracture healing; HRpQCT; implant; distal radius; CFR-PEEK
Document URI: http://hdl.handle.net/1942/24064
ISSN: 1471-2342
e-ISSN: 1471-2342
DOI: 10.1186/s12880-017-0190-z
ISI #: 000395943900001
Rights: © The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Category: A1
Type: Journal Contribution
Validations: ecoom 2018
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
de jong 1.pdfPublished version799.97 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

10
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

14
checked on Apr 22, 2024

Page view(s)

66
checked on Sep 7, 2022

Download(s)

96
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.