Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/29252
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAGTEN, Anouk-
dc.contributor.advisorVANDENABEELE, Frank-
dc.contributor.authorCornelissen, Simon-
dc.contributor.authorvan der Velden, Max-
dc.date.accessioned2019-09-17T08:27:12Z-
dc.date.available2019-09-17T08:27:12Z-
dc.date.issued2019-
dc.identifier.urihttp://hdl.handle.net/1942/29252-
dc.description.abstractBackground: 3D ultrasound is proven to be a time saving, cost-effective alternative to magnetic resonance imaging (MRI) when measuring muscle volumes of certain muscles. No research has yet been done to evaluate the reliability of a 3D ultrasound apparatus to investigate muscle volume of deeply located trunk muscles, such as the multifidus (MF) muscle, by inexperienced examiners. Objectives: The purpose of this Master’s thesis is to evaluate the inter-rater and intra-rater reliability of a 3D freehand ultrasound apparatus to measure the muscle volume of the MF. This study investigates the reliability of inexperienced ultrasonographers in particular. Participants: Ten women and ten men under the age of 60 years were recruited through local advertisement and were screened for eligibility. Measurements: Measurements of the MF were conducted in a standardized manner by both examiners to calculate intra-rater reliability, and again, by the first examiner to calculate the inter-rater reliability. Subsequently, the obtained ultrasound slices were examined separately by each examiner. Results: The inter-rater reliability showed poor to good reliability (ICC: 0.718; 95% CI: 0.251-0.894). Intra-rater reliability scored higher with moderate to excellent reliability (ICC: 0.863; 95% CI: 0.670-0.946). Two participants were excluded due to measurement errors. Keywords: 3D ultrasound, reliability, inter-rater, intra-rater, inexperienced, multifidus muscle, ultrasonographers, imaging-
dc.format.mimetypeApplication/pdf-
dc.languagenl-
dc.publisherUHasselt-
dc.titleAn evaluation of the inter-rater and intra-rater reliability in volume measurements with a 3D ultrasound apparatus of the musculus multifidus in healthy subjects-
dc.typeTheses and Dissertations-
local.format.pages0-
local.bibliographicCitation.jcatT2-
dc.description.notesmaster in de revalidatiewetenschappen en de kinesitherapie-revalidatiewetenschappen en kinesitherapie bij musculoskeletale aandoeningen-
local.type.specifiedMaster thesis-
item.contributorCornelissen, Simon-
item.contributorvan der Velden, Max-
item.accessRightsOpen Access-
item.fullcitationCornelissen, Simon & van der Velden, Max (2019) An evaluation of the inter-rater and intra-rater reliability in volume measurements with a 3D ultrasound apparatus of the musculus multifidus in healthy subjects.-
item.fulltextWith Fulltext-
Appears in Collections:Master theses
Files in This Item:
File Description SizeFormat 
5137f4d3-36e3-45b2-b002-dff3fbd3d83c.pdf1.25 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.