Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/10328
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | GIELEN, Ellen | - |
dc.contributor.author | SMISDOM, Nick | - |
dc.contributor.author | VAN DE VEN, Martin | - |
dc.contributor.author | DE CLERCQ, Ben | - |
dc.contributor.author | Gratton, Enrico | - |
dc.contributor.author | Digman, Michelle | - |
dc.contributor.author | RIGO, Jean-Michel | - |
dc.contributor.author | Hofkens, Johan | - |
dc.contributor.author | Engelborghs, Yves | - |
dc.contributor.author | AMELOOT, Marcel | - |
dc.date.accessioned | 2010-01-08T14:40:30Z | - |
dc.date.available | 2010-01-08T14:40:30Z | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | LANGMUIR, 25(9). p. 5209-5218 | - |
dc.identifier.issn | 0743-7463 | - |
dc.identifier.uri | http://hdl.handle.net/1942/10328 | - |
dc.description.abstract | The heterogeneity in composition and interaction within the cellular membrane translates into a wide range of diffusion coefficients of its constituents. Therefore, several complementary microfluorimetric techniques such as fluorescence correlation spectroscopy (FCS), fluorescence recovery after photobleaching (FRAP) and single-particle tracking (SPT) have to be applied to explore the dynamics of membrane components. The recently introduced raster image correlation spectroscopy (RICS) offers a much wider dynamic range than each of these methods separately and allows for spatial mapping of the dynamic properties. RICS is implemented on a confocal laser-scanning microscope (CLSM), and the wide dynamic range is achieved by exploiting the inherent time information carried by the scanning laser beam in the generation of the confocal images. The original introduction of RICS used two-photon excitation and photon counting detection. However, most CLSM systems are based on one-photon excitation with analog detection. Here we report on the performance of such a commercial CLSM (Zeiss LSM 510 META) in the study of the diffusion of the fluorescent lipid analog 1,1'-dioctadecyl-3,3,3',3'-tetramethyl-indodicarbocyanine perchlorate (Dil-C-18(5)) both in giant unilamellar vesicles and in the plasma membrane of living oligodendrocytes, i.e., the myelin-producing cells of the central nervous system. It is shown that RICS on a commercial CLSM with analog detection allows for reliable results in the study of membrane diffusion by removal of unwanted correlations introduced by the analog detection system. The results obtained compare well with those collected by FRAP and FCS. | - |
dc.description.sponsorship | Research Council of the UHasselt tUL KULeuven GOA/2006/02 IWT-Vlaanderen Functional Supramolecular Systems (BELSPO) IAP P6/27 FWO-onderzoeksgemeenschap "Scanning and Wide Field Microscopy of (Bio)-organic Systems" | - |
dc.language.iso | en | - |
dc.publisher | ACS Publications | - |
dc.subject.other | FLUORESCENCE CORRELATION SPECTROSCOPY; CROSS-CORRELATION SPECTROSCOPY; PLASMA-MEMBRANE; CELL; DYNAMICS; LAWS; OLIGODENDROCYTE; CONFINEMENT; MYELIN; RAFTS | - |
dc.title | Measuring Diffusion of Lipid-like Probes in Artificial and Natural Membranes by Raster Image Correlation Spectroscopy (RICS): Use of a Commercial Laser-Scanning Microscope with Analog Detection | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 5218 | - |
dc.identifier.issue | 9 | - |
dc.identifier.spage | 5209 | - |
dc.identifier.volume | 25 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | Reprint Address: Ameloot, M (reprint author), Hasselt Univ, Biomed Res Inst, Lab Cell Physiol, Agoralaan,Bldg C, B-3590 Diepenbeek, Belgium | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.bibliographicCitation.oldjcat | A1 | - |
dc.identifier.doi | 10.1021/la8040538 | - |
dc.identifier.isi | 000265528600053 | - |
dc.identifier.url | 10.1021/la8040538 | - |
item.fullcitation | GIELEN, Ellen; SMISDOM, Nick; VAN DE VEN, Martin; DE CLERCQ, Ben; Gratton, Enrico; Digman, Michelle; RIGO, Jean-Michel; Hofkens, Johan; Engelborghs, Yves & AMELOOT, Marcel (2009) Measuring Diffusion of Lipid-like Probes in Artificial and Natural Membranes by Raster Image Correlation Spectroscopy (RICS): Use of a Commercial Laser-Scanning Microscope with Analog Detection. In: LANGMUIR, 25(9). p. 5209-5218. | - |
item.contributor | GIELEN, Ellen | - |
item.contributor | SMISDOM, Nick | - |
item.contributor | VAN DE VEN, Martin | - |
item.contributor | DE CLERCQ, Ben | - |
item.contributor | Gratton, Enrico | - |
item.contributor | Digman, Michelle | - |
item.contributor | RIGO, Jean-Michel | - |
item.contributor | Hofkens, Johan | - |
item.contributor | Engelborghs, Yves | - |
item.contributor | AMELOOT, Marcel | - |
item.validation | ecoom 2010 | - |
item.accessRights | Closed Access | - |
item.fulltext | No Fulltext | - |
crisitem.journal.issn | 0743-7463 | - |
crisitem.journal.eissn | 1520-5827 | - |
Appears in Collections: | Research publications |
SCOPUSTM
Citations
48
checked on Sep 5, 2020
WEB OF SCIENCETM
Citations
52
checked on Sep 20, 2024
Page view(s)
98
checked on Jun 19, 2023
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.