Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/11046
Title: A MIP-based biomimetic sensor for the impedimetric detection of histamine in different pH environments
Authors: BONGAERS, Evi 
ALENUS, Jan 
HOREMANS, Frederik 
WEUSTENRAED, Ans 
LUTSEN, Laurence 
VANDERZANDE, Dirk 
CLEIJ, Thomas 
TROOSTERS, Johan 
Brummer, RJ
WAGNER, Patrick 
Issue Date: 2010
Publisher: WILEY-V C H VERLAG GMBH
Source: PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 207(4). p. 837-843
Abstract: The development of novel biosensors is a rapidly growing field. Substituting the biological receptor layer from the biosensor with a synthetic receptor opens the door for the development of biomimetic sensors that are chemically and physically inert, as opposed to the sensors containing biological recognition elements. Using molecularly imprinted polymers (MIPs) the specificity and affinity of biological receptors can be mimicked. In addition, a MIP-based sensor can measure in harsh environments. Histamine occurs in harsh environments in food and bodily fluids and is chosen as the target molecule for impedimetric detection: When 10 nM histamine is present in pH neutral environments, the impedance increases 45% with respect to the impedance of the sensor without histamine. Specificity is tested with respect to histidine. The influence of the pH on the performance of the sensor is tested. In a pH range of pH 5-12 the MIPs are stable, although they exhibit a varying degree of protonation. The same holds true for the target molecule of which the protonation also varies with the pH of the solution. It is shown that the pH dependent degree of protonation of both the MIP and the histamine has a large impact on the binding of histamine to the nanocavity in the MIP. Hence, the detection of histamine by a MIP-based sensor is affected by the PH of the solution. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
Notes: [Bongaers, E.; Alenus, J.; Horemans, F.; Weustenraed, A.; Vanderzande, D.; Cleij, T. J.; Wagner, P.] Hasselt Univ, Inst Mat Res, B-3590 Diepenbeek, Belgium. [Lutsen, L.; Vanderzande, D.; Wagner, P.] IMEC, Div IMOMEC, B-3590 Diepenbeek, Belgium. [Troost, F. J.; Brummer, R. -J.] Maastricht Univ, NUTRIM, Dept Internal Med, NL-6229 ER Maastricht, Netherlands. Evi.Bongaers@uhasselt.be; Patrick.Wagner@uhasselt.be
Keywords: biosensor; electrochemical sensors; biomaterials;biosensor; electrochemical sensors; biomaterials
Document URI: http://hdl.handle.net/1942/11046
ISSN: 1862-6300
e-ISSN: 1862-6319
DOI: 10.1002/pssa.200983307
ISI #: 000277565300011
Category: A1
Type: Journal Contribution
Validations: ecoom 2011
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
bongaers 1.pdf
  Restricted Access
Published version339.74 kBAdobe PDFView/Open    Request a copy
Show full item record

SCOPUSTM   
Citations

36
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

47
checked on Apr 21, 2024

Page view(s)

126
checked on Jun 13, 2022

Download(s)

108
checked on Jun 13, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.