Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/11884
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Breusegem, Christophe | - |
dc.contributor.author | FIEUWS, Steffen | - |
dc.contributor.author | Stalmans, Ingeborg | - |
dc.contributor.author | Zeyen, Thierry | - |
dc.date.accessioned | 2011-04-27T14:14:16Z | - |
dc.date.available | NO_RESTRICTION | - |
dc.date.available | 2011-04-27T14:14:16Z | - |
dc.date.issued | 2011 | - |
dc.identifier.citation | OPHTHALMOLOGY, 118(4). p. 742-746 | - |
dc.identifier.issn | 0161-6420 | - |
dc.identifier.uri | http://hdl.handle.net/1942/11884 | - |
dc.description.abstract | Purpose: To compare the interobserver agreement in detecting glaucomatous optic disc changes using serial stereophotography between a large group of non-expert ophthalmologists and glaucoma specialists; to assess the accuracy of non-experts; to investigate whether the interobserver agreement and the accuracy of non-experts changed after a training session. Design: Masked interobserver agreement study. Participants: Serial optic disc stereophotos from 40 patients with glaucoma. Methods: Three independent experienced glaucoma specialists (readers of the European Glaucoma Prevention Study) evaluated a set of 2 serial optic disc color stereo-slides for glaucomatous change, obtained with a delay varying from 2 to 7 years of 40 patients, masked from the temporal sequence of the slides. Each patient was graded as changed or stable by agreement of 2 of 3 of the experts (the reference standard). Thirty-seven non-expert ophthalmologists independently evaluated the same set of serial optic disc stereo-slides twice, with the second evaluation on the same day, masked from the results of the previous evaluation, after a training session on a separate slide set. Main Outcome Measures: Interobserver agreement of non-experts and experts in detecting glaucomatous optic disc changes (expressed as kappa coefficient); agreement of non-experts with the reference standard (accuracy) before and after a training session. Results: The interobserver kappa coefficient (kappa) of the non-experts and experts was 0.20 (95% confidence interval [CI], 0.19-0.21) and 0.51 (95% CI, 0.33-0.69), respectively (P < 0.0001). The mean kappa of the non-experts with the reference standard was 0.33 (95% CI, 0.27-0.39). After a training session, the interobserver agreement of the non-experts increased from 0.20 to 0.27 (95% CI, 0.26-0.28) (P < 0.0001). The percentage agreement of the non-experts with the reference standard improved from 68.5% before to 71.4% after the training session (Wilcoxon signed-rank test, P = 0.034). Conclusions: The interobserver agreement of non-expert ophthalmologists in detecting glaucomatous optic disc changes using serial stereophotos was significantly lower than that of experts, which was moderate. After a training session, the interobserver agreement and the accuracy of the non-experts showed a small but statistically significant improvement. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2011;118:742-746 (C) 2011 by the American Academy of Ophthalmology. | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE INC | - |
dc.title | Agreement and Accuracy of Non-Expert Ophthalmologists in Assessing Glaucomatous Changes in Serial Stereo Optic Disc Photographs | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 746 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 742 | - |
dc.identifier.volume | 118 | - |
local.format.pages | 5 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | [Breusegem, Christophe; Stalmans, Ingeborg; Zeyen, Thierry] Leuven Univ Hosp, Dept Ophthalmol, B-3000 Louvain, Belgium. [Fieuws, Steffen] Katholieke Univ Leuven, Louvain, Belgium. [Fieuws, Steffen] Univ Hasselt, Hasselt, Belgium. | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.bibliographicCitation.oldjcat | A1 | - |
dc.identifier.doi | 10.1016/j.ophtha.2010.08.019 | - |
dc.identifier.isi | 000289075200021 | - |
item.fullcitation | Breusegem, Christophe; FIEUWS, Steffen; Stalmans, Ingeborg & Zeyen, Thierry (2011) Agreement and Accuracy of Non-Expert Ophthalmologists in Assessing Glaucomatous Changes in Serial Stereo Optic Disc Photographs. In: OPHTHALMOLOGY, 118(4). p. 742-746. | - |
item.fulltext | No Fulltext | - |
item.contributor | Breusegem, Christophe | - |
item.contributor | FIEUWS, Steffen | - |
item.contributor | Stalmans, Ingeborg | - |
item.contributor | Zeyen, Thierry | - |
item.validation | ecoom 2012 | - |
item.accessRights | Closed Access | - |
crisitem.journal.issn | 0161-6420 | - |
crisitem.journal.eissn | 1549-4713 | - |
Appears in Collections: | Research publications |
SCOPUSTM
Citations
31
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
45
checked on Sep 12, 2024
Page view(s)
56
checked on Sep 7, 2022
Google ScholarTM
Check
Altmetric