Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/11884
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBreusegem, Christophe-
dc.contributor.authorFIEUWS, Steffen-
dc.contributor.authorStalmans, Ingeborg-
dc.contributor.authorZeyen, Thierry-
dc.date.accessioned2011-04-27T14:14:16Z-
dc.date.availableNO_RESTRICTION-
dc.date.available2011-04-27T14:14:16Z-
dc.date.issued2011-
dc.identifier.citationOPHTHALMOLOGY, 118(4). p. 742-746-
dc.identifier.issn0161-6420-
dc.identifier.urihttp://hdl.handle.net/1942/11884-
dc.description.abstractPurpose: To compare the interobserver agreement in detecting glaucomatous optic disc changes using serial stereophotography between a large group of non-expert ophthalmologists and glaucoma specialists; to assess the accuracy of non-experts; to investigate whether the interobserver agreement and the accuracy of non-experts changed after a training session. Design: Masked interobserver agreement study. Participants: Serial optic disc stereophotos from 40 patients with glaucoma. Methods: Three independent experienced glaucoma specialists (readers of the European Glaucoma Prevention Study) evaluated a set of 2 serial optic disc color stereo-slides for glaucomatous change, obtained with a delay varying from 2 to 7 years of 40 patients, masked from the temporal sequence of the slides. Each patient was graded as changed or stable by agreement of 2 of 3 of the experts (the reference standard). Thirty-seven non-expert ophthalmologists independently evaluated the same set of serial optic disc stereo-slides twice, with the second evaluation on the same day, masked from the results of the previous evaluation, after a training session on a separate slide set. Main Outcome Measures: Interobserver agreement of non-experts and experts in detecting glaucomatous optic disc changes (expressed as kappa coefficient); agreement of non-experts with the reference standard (accuracy) before and after a training session. Results: The interobserver kappa coefficient (kappa) of the non-experts and experts was 0.20 (95% confidence interval [CI], 0.19-0.21) and 0.51 (95% CI, 0.33-0.69), respectively (P < 0.0001). The mean kappa of the non-experts with the reference standard was 0.33 (95% CI, 0.27-0.39). After a training session, the interobserver agreement of the non-experts increased from 0.20 to 0.27 (95% CI, 0.26-0.28) (P < 0.0001). The percentage agreement of the non-experts with the reference standard improved from 68.5% before to 71.4% after the training session (Wilcoxon signed-rank test, P = 0.034). Conclusions: The interobserver agreement of non-expert ophthalmologists in detecting glaucomatous optic disc changes using serial stereophotos was significantly lower than that of experts, which was moderate. After a training session, the interobserver agreement and the accuracy of the non-experts showed a small but statistically significant improvement. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2011;118:742-746 (C) 2011 by the American Academy of Ophthalmology.-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.titleAgreement and Accuracy of Non-Expert Ophthalmologists in Assessing Glaucomatous Changes in Serial Stereo Optic Disc Photographs-
dc.typeJournal Contribution-
dc.identifier.epage746-
dc.identifier.issue4-
dc.identifier.spage742-
dc.identifier.volume118-
local.format.pages5-
local.bibliographicCitation.jcatA1-
dc.description.notes[Breusegem, Christophe; Stalmans, Ingeborg; Zeyen, Thierry] Leuven Univ Hosp, Dept Ophthalmol, B-3000 Louvain, Belgium. [Fieuws, Steffen] Katholieke Univ Leuven, Louvain, Belgium. [Fieuws, Steffen] Univ Hasselt, Hasselt, Belgium.-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.doi10.1016/j.ophtha.2010.08.019-
dc.identifier.isi000289075200021-
item.contributorBreusegem, Christophe-
item.contributorFIEUWS, Steffen-
item.contributorStalmans, Ingeborg-
item.contributorZeyen, Thierry-
item.accessRightsClosed Access-
item.fullcitationBreusegem, Christophe; FIEUWS, Steffen; Stalmans, Ingeborg & Zeyen, Thierry (2011) Agreement and Accuracy of Non-Expert Ophthalmologists in Assessing Glaucomatous Changes in Serial Stereo Optic Disc Photographs. In: OPHTHALMOLOGY, 118(4). p. 742-746.-
item.fulltextNo Fulltext-
item.validationecoom 2012-
crisitem.journal.issn0161-6420-
crisitem.journal.eissn1549-4713-
Appears in Collections:Research publications
Show simple item record

SCOPUSTM   
Citations

31
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

43
checked on Apr 23, 2024

Page view(s)

56
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.