Title: Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves
Authors: Flameng, Willem
Herregods, Marie-Christine
Vercalsteren, Monique
Herijgers, Paul
BOGAERTS, Kris 
Meuris, Bart
Issue Date: 2010
Publisher: LIPPINCOTT WILLIAMS & WILKINS
Source: CIRCULATION, 121(19), p. 2123-2129
Abstract: Background-Prosthesis-patient mismatch (P-PtM) after aortic valve replacement results in disturbed valve performance associated with increased pressure gradients. However, it is unknown whether this can be related to future structural valve deterioration (SVD) of the bioprosthesis. Methods and Results-In 564 patients (mean age, 74+/-5 years) receiving an aortic valve bioprosthesis, clinical follow-up (median, 6.1 years; maximum, 16.4 years) was analyzed including echocardiography. SVD was diagnosed in 40 patients (7%) as substantially increased stenosis (n=24) or regurgitation (n=16) of the operated valve over time. When patients with P-PtM (effective orifice area index <0.85 cm(2)/m(2); n=285) developed SVD, it was preferentially of the stenosis type, whereas when patients without P-PtM (n=279) developed SVD, the majority was of the incompetence type (P<0.05). Multivariable analysis including patient-and valve-related variables revealed that P-PtM and label size <= 21 were independent predictors of SVD (P=0.04 and P=0.02, respectively). A nonparametric Turnbull estimate analysis showed that SVD is virtually nonexistent for up to 9 years in patients without P-PtM. Thereafter, SVD starts to occur and is mainly of the incompetence-type SVD (79% of cases). In patients with P-PtM, SVD starts to occur after 2 to 3 years after implantation and is mainly of the stenosis-type SVD (81% of cases). Conclusions-These data suggest that stenosis-type SVD is an early, P-PtM-related, and thus preventable phenomenon. Incompetence-type SVD is a time-dependent, nonspecific wear damage to bioprosthetic valves, which is not related to P-PtM. (Circulation. 2010; 121: 2123-2129.)
Notes: [Flameng, W; Vercalsteren, M; Herijgers, P; Meuris, B] Katholieke Univ Leuven, Dept Cardiovasc Dis, Div Cardiac Surg, Leuven, Belgium. [Herregods, MC] Katholieke Univ Leuven, Dept Cardiovasc Dis, Dept Cardiol, Leuven, Belgium. [Bogaerts, K] Univ Hasselt, Ctr Biostat, Diepenbeek, Belgium.
Keywords: bioprosthesis; prosthesis-patient mismatch; surgery; valves
Document URI: http://hdl.handle.net/1942/12822
ISSN: 0009-7322
e-ISSN: 1524-4539
DOI: 10.1161/CIRCULATIONAHA.109.901272
ISI #: 000277769900007
Category: A1
Type: Journal Contribution
Validations: ecoom 2011
Appears in Collections:Research publications

Show full item record

SCOPUSTM   
Citations

135
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

202
checked on May 1, 2024

Page view(s)

66
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.