Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/12997
Title: | Electrochemical sensor array for bioprocess monitoring | Authors: | Bäcker, M. DELLE, Lotta Poghossian, A. Biselli, M. Zang, W. WAGNER, Patrick Schöning, M. J. |
Issue Date: | 2011 | Publisher: | PERGAMON-ELSEVIER SCIENCE LTD | Source: | ELECTROCHIMICA ACTA, 56 (26), p. 9673-9678 | Abstract: | A silicon-based biosensor chip consisting of an array of amperometric enzyme sensors has been developed for monitoring the concentration of glutamate and glutamine in cell-culture fermentation processes. The glutamate sensor was constructed by immobilising glutamate oxidase, while the glutamine sensor by sequential coupling of glutaminase and glutamate oxidase. The enzymes were immobilised by means of cross-linking with glutaraldehyde on the surface of the patterned platinum thin-film electrodes. The developed biosensors have been electrochemically characterised in solutions with different concentrations of glutamate and glutamine in terms of sensitivity, response time, linear working range and lifetime. A high sensitivity of 96 nA/mM and 100 nA/mM was registered for the glutamate and glutamine sensors, respectively. The preliminary experiments in cell-culture medium have shown a good correlation between the glutamine and glutamate concentrations measured with the biosensor chip and the commercially available biochemistry analyser. The obtained results demonstrate the feasibility of the realised biosensor chip for monitoring the glutamine and glutamate concentrations in fermentation processes. (C) 2011 Elsevier Ltd. All rights reserved. | Notes: | Schoning, MJ (reprint author); Aachen Univ Appl Sci, Inst Nano & Biotechnol INB, Campus Julich, Aachen, Germany. [Baecker, M.; Delle, L.; Poghossian, A.; Biselli, M.; Schoening, M. J.] Aachen Univ Appl Sci, Inst Nano & Biotechnol INB, Aachen, Germany. [Baecker, M.; Poghossian, A.; Schoening, M. J.] Res Ctr Julich GmbH, Peter Grunberg Inst PGI 8, Julich, Germany. [Zang, W.] HiTec Zang GmbH, Herzogenrath, Germany. [Wagner, P.] Hasselt Univ, Inst Mat Res, Diepenbeek, Belgium. schoening@fh-aachen.de | Keywords: | Electrochemistry;Amperometric sensor array; Enzymatic biosensor; Bioprocess monitoring; Glutamine; Glutamate | Document URI: | http://hdl.handle.net/1942/12997 | ISSN: | 0013-4686 | e-ISSN: | 1873-3859 | DOI: | 10.1016/j.electacta.2011.04.030 | ISI #: | 000297493300022 | Category: | A1 | Type: | Journal Contribution | Validations: | ecoom 2012 |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
backer1.pdf Restricted Access | Published version | 663.29 kB | Adobe PDF | View/Open Request a copy |
SCOPUSTM
Citations
15
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
18
checked on Oct 12, 2024
Page view(s)
98
checked on Sep 7, 2022
Download(s)
84
checked on Sep 7, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.