Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/13324
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVANACKEN, Lode-
dc.contributor.authorPinho, Romulo-
dc.contributor.authorSijbers, Jan-
dc.contributor.authorCONINX, Karin-
dc.date.accessioned2012-03-06T13:55:55Z-
dc.date.available2012-03-06T13:55:55Z-
dc.date.issued2012-
dc.identifier.citationAdvances in Human-Computer Interaction, 2012 (Article ID 632498), p. 1-9-
dc.identifier.issn1687-5907-
dc.identifier.urihttp://hdl.handle.net/1942/13324-
dc.description.abstractManual segmentation of structures for diagnosis and treatment of various diseases is a very time-consuming procedure. Therefore, some level of automation during the segmentation is desired, as it often significantly reduces the segmentation time. A typical solution is to allow manual interaction to steer the segmentation process, which is known as semiautomatic segmentation. In 2D, such interaction is usually achieved with click-and-drag operations, but in 3D a more sophisticated interface is called for. In this paper, we propose a semi-automatic Active Contour Modelling for the delineation of medical structures in 3D, tomographic images. Interaction is implemented with the employment of a 3D haptic device, which is used to steer the contour deformation towards the correct boundaries. In this way, valuable haptic feedback is provided about the 3D surface and its deformation. Experiments on simulated and real tracheal CT data showed that the proposed technique is an intuitive and effective segmentation mechanism.-
dc.language.isoen-
dc.titleForce Feedback to Assist Active Contour Modelling for Tracheal Stenosis Segmentation-
dc.typeJournal Contribution-
dc.identifier.epage9-
dc.identifier.issueArticle ID 632498-
dc.identifier.spage1-
dc.identifier.volume2012-
local.bibliographicCitation.jcatA1-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA2-
local.identifier.vabbc:vabb:340343-
dc.identifier.doi10.1155/2012/632498-
item.contributorVANACKEN, Lode-
item.contributorPinho, Romulo-
item.contributorSijbers, Jan-
item.contributorCONINX, Karin-
item.fulltextWith Fulltext-
item.validationvabb 2014-
item.fullcitationVANACKEN, Lode; Pinho, Romulo; Sijbers, Jan & CONINX, Karin (2012) Force Feedback to Assist Active Contour Modelling for Tracheal Stenosis Segmentation. In: Advances in Human-Computer Interaction, 2012 (Article ID 632498), p. 1-9.-
item.accessRightsOpen Access-
crisitem.journal.issn1687-5893-
crisitem.journal.eissn1687-5907-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Vanacken-force feedback.pdf2.69 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

1
checked on Sep 2, 2020

Page view(s)

74
checked on Aug 25, 2023

Download(s)

134
checked on Aug 25, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.