Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/14446
Title: Nine Month Imaging and Twelve Month Clinical Results from the DESSOLVE II Randomized Trial of the MiStent (R) SES with Absorbable Polymer
Authors: Wijns, William
VROLIX, Mathias 
Verheye, Stefan
Schoors, Danny
Slagboom, Ton
Gosselink, Marcel
BENIT, Edouard 
Desmet, Walter
Chowdhary, Saquib
Lansky, Alexandra
Bezerra, Hiram
Fitzgerald, Peter
Kandzari, David
Ormiston, John
Issue Date: 2012
Publisher: ELSEVIER SCIENCE INC
Source: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 60 (17), p. B169-B170
Abstract: Background : The MiStent SES (Micell Technologies, Durham, NC) is an investigational drug-eluting stent (DES) developed to adress unfavorable late-term outcomes such as stent thrombosis. These events are hypothesized to be associated in part with durable polymers of current DES. The MiStent SES uses a unique combination of components, a crystalline formulation of sirolimus and a fully absorbable polymer on a thinstrut, cobalt chromium stent platform. The polymer coating is eliminated from the stent in 45-60 days with complete absorption in 90 days. Sirolimus is simultaneously released into the surrounding tissue as a controlled elution. Methods: The DESSOLVE II clinical trial is a 2:1 randomized study conducted at 26 sites evaluating the MiStent SES for superiority in late lumen loss as compared to the control stent, the Medtronic Endeavor Sprint (Santa Rosa, CA). Patients with discrete de novo lesions (2.5-3.5 mm vessel diameter and ≤27 mm length) in native coronary arteries were acceptable for inclusion in the trial. A total of 183 patients were randomized into either the MiStent SES or Endeavour Sprint and patients had follow-up at 30-days, 6, 9 and 12-months post-procedure. Angiography was conducted at 9-months with two subgroups: 38 patients imaged using optical coherence tomography (OCT) and 29 patients participated in endothelial function testing(EFT). Results: The MiStent was superior to Endeavour for the primary endpoint analysis of late lumen loss. The OCT revealed a mean of 2% uncovered struts with good suppression on neointimal hyperplasia. EFT demonstrated an overall return of endothelial function with no incidence of vasoconstriction in either the test or control group. Additional secondary endpoint data will be presented. Conclusion: The MiStent SES is an innovative drug eluting stent with sirolimus in a fully absorbable polymer demonstrating a superior performance as compared to the Endeavor Sprint DES. OCT shows stent coverage at 9-months with a return of endothelial function.
Notes: [Wijns, William] Cardiovasc Ctr Aalst, Aalst, Belgium. [Vrolix, Mathias] Hosp Oost Limburg, Genk, Belgium. [Verheye, Stefan] Antwerp Cardiovasc Ctr, Antwerp, Belgium. [Schoors, Danny] Brussels Univ Hosp, Brussels, Belgium. [Slagboom, Ton] Onze Lieve Vrouw Hosp, Amsterdam, Netherlands. [Gosselink, Marcel] Isala Klin, Zwolle, Netherlands. [Benit, Edouard] Heart Ctr Hasselt, Hasselt, Hasselt, Belgium. [Desmet, Walter] Catholic Univ Louvain, B-3000 Louvain, Belgium. [Chowdhary, Saquib] Wythenshawe Hosp, Manchester M23 9LT, Lancs, England. [Lansky, Alexandra] Yale Univ, Sch Med, New Haven, CT USA. [Bezerra, Hiram] Case Western Reserve Univ, Cleveland, OH 44106 USA. [Fitzgerald, Peter] Stanford Univ, Med Ctr, Stanford, CA 94305 USA. [Kandzari, David] Piedmont Heart Inst, Atlanta, GA USA. [Ormiston, John] Mercy Angiog Unit, Auckland, New Zealand.
Keywords: Cardiac & Cardiovascular Systems
Document URI: http://hdl.handle.net/1942/14446
ISSN: 0735-1097
e-ISSN: 1558-3597
DOI: 10.1016/j.jacc.2012.08.619
ISI #: 000310210101377
Category: M
Type: Journal Contribution
Appears in Collections:Research publications

Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.