Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/14587
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBOHRN, Ulrich-
dc.contributor.authorStuetz, Evamaria-
dc.contributor.authorFleischer, Maximilian-
dc.contributor.authorSchoening, Michael J.-
dc.contributor.authorWAGNER, Patrick-
dc.date.accessioned2013-02-20T14:33:13Z-
dc.date.available2013-02-20T14:33:13Z-
dc.date.issued2013-
dc.identifier.citationBIOSENSORS & BIOELECTRONICS, 40 (1), p. 393-400-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://hdl.handle.net/1942/14587-
dc.description.abstractIn this study, a cell-based gas biosensor is presented used for the detection and investigation of gaseous organic compounds in air. The response of living human nasal cells (RPMI 2650) and human lung cells (A549) towards the direct exposure of gaseous substances for 10 min is monitored with a multiparametric sensor system. Changes in the cellular impedance, oxygen consumption rate and acidification rate can be recorded after the exposure and represent the cytotoxicity of the present gas. The sensor is able to notify the presence of acetone in aqueous solution (2%) but in notably lower concentrations in the gas phase (100-333 ppm) within 30-60 min after the end of the gas exposure. Cell viability is not affected by a sequential exposure to humidified synthetic air (60% r.h.) with a flow rate of 300 ml/min and therefore offers the possibility for a continuous air monitoring. In addition, exposure to synthetic air has no influence on the signals of consecutive acetone exposure. The system might be used in the future for the monitoring of ambient air in work spaces. (C) 2012 Elsevier B.V. All rights reserved.-
dc.language.isoen-
dc.publisherELSEVIER ADVANCED TECHNOLOGY-
dc.subject.otherCell-based gas biosensor; Acetone; A549; RPMI 2650; Impedance; Respiration-
dc.subject.otherBiophysics; Biotechnology & Applied Microbiology; Chemistry, Analytical; Electrochemistry; Nanoscience & Nanotechnology; cell-based gas biosensor; acetone; A549; RPMI 2650; impedance; respiration-
dc.titleUsing a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro-
dc.typeJournal Contribution-
local.bibliographicCitation.conferencedateMAY 15-18, 2012-
local.bibliographicCitation.conferencename22nd Anniversary World Congress on Biosensors / Summer School on Printed Biosensors and Electronics-
local.bibliographicCitation.conferenceplaceCancun, MEXICO-
dc.identifier.epage400-
dc.identifier.issue1-
dc.identifier.spage393-
dc.identifier.volume40-
local.format.pages8-
local.bibliographicCitation.jcatA1-
dc.description.notes[Bohrn, Ulrich; Stuetz, Evamaria; Fleischer, Maximilian] Siemens AG, Corp Res & Technol, D-81739 Munich, Germany. [Bohrn, Ulrich; Schoening, Michael J.] Aachen Univ Appl Sci, INB, D-52428 Julich, Germany. [Bohrn, Ulrich; Wagner, Patrick] Hasselt Univ, Inst Mat Res IMO IMOMEC, B-3590 Diepenbeek, Belgium. ulrichbohrn@hotmail.com-
local.publisher.placeOXFORD-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1016/j.bios.2012.08.029-
dc.identifier.isi000312825800061-
item.contributorBOHRN, Ulrich-
item.contributorStuetz, Evamaria-
item.contributorFleischer, Maximilian-
item.contributorSchoening, Michael J.-
item.contributorWAGNER, Patrick-
item.accessRightsRestricted Access-
item.fullcitationBOHRN, Ulrich; Stuetz, Evamaria; Fleischer, Maximilian; Schoening, Michael J. & WAGNER, Patrick (2013) Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro. In: BIOSENSORS & BIOELECTRONICS, 40 (1), p. 393-400.-
item.fulltextWith Fulltext-
item.validationecoom 2014-
crisitem.journal.issn0956-5663-
crisitem.journal.eissn1873-4235-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
bohrn 1.pdf
  Restricted Access
Published version1.27 MBAdobe PDFView/Open    Request a copy
Show simple item record

SCOPUSTM   
Citations

5
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

6
checked on Apr 22, 2024

Page view(s)

46
checked on Sep 7, 2022

Download(s)

40
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.