Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/15459
Title: Comparing normal saline versus diluted heparin to lock non-valved totally implantable venous access devices in cancer patients: a randomised, non-inferiority, open trial
Authors: Goossens, G. A.
Jerome, M.
Janssens, C.
Peetermans, W. E.
FIEUWS, Steffen 
Moons, Philip
Verschakelen, J.
Peerlinck, K.
Jacquemin, M.
Stas, M.
Issue Date: 2013
Publisher: OXFORD UNIV PRESS
Source: ANNALS OF ONCOLOGY, 24 (7), p. 1892-1899
Abstract: Background: Heparin has been used for years as a locking solution in totally implantable venous access devices. Normal saline (NS) might be a safe alternative for heparin. However, evidence of non-inferiority of NS versus heparin is lacking. Patients and methods: We randomly allocated 802 cancer patients with a newly inserted port either to heparin lock (300 U/3 ml) or to NS lock groups in a 1:1 assignment ratio. The primary outcome was the number of functional complications, which was defined as 'easy injection, impossible aspiration' at port access. Secondary outcomes included all functional problems and catheter-related bacteraemia. We hypothesised that NS locks do not cause more functional problems and catheter-related bacteraemia than heparin locks. Non-inferiority is established if the upper limit of the confidence interval (CI) for the relative risk of NS versus heparin is <1.4. Results: Three hundred and eighty-two patients from the NS group and 383 from the heparin lock group were included in the analysis. The incidence rate of our primary outcome (easy injection, impossible aspiration) was 3.70% (95% CI 2.91%-4.69%) and 3.92% (95% CI 3.09%-4.96%) of accesses in the NS and heparin groups, respectively. The relative risk was 0.94% (95% CI 0.67%-1.32%). Catheter-related bloodstream infection was 0.03 per 1000 catheter days in the NS group and 0.10 per 1000 catheter days in the heparin group. Conclusion: NS is a safe and effective locking solution in implantable ports if combined with a strict protocol for device insertion and maintenance.
Notes: [Goossens, G. A.; Jerome, M.; Janssens, C.] Univ Hosp Leuven, Nursing Ctr Excellence, B-3000 Louvain, Belgium. [Goossens, G. A.; Moons, P.] Katholieke Univ Leuven, Dept Publ Hlth & Primary Care, Louvain, Belgium. [Peetermans, W. E.] Univ Hosp Leuven, Dept Internal Med, B-3000 Louvain, Belgium. [Fieuws, S.] Katholieke Univ Leuven, Interuniv Ctr Biostat & Stat Bioinformat, Louvain, Belgium. [Fieuws, S.] Univ Hasselt, Interuniv Ctr Biostat & Stat Bioinformat, Hasselt, Belgium. [Verschakelen, J.] Univ Hosp Leuven, Dept Radiol, B-3000 Louvain, Belgium. [Peerlinck, K.; Jacquemin, M.] Katholieke Univ Leuven, Ctr Mol & Vasc Biol, Louvain, Belgium. [Stas, M.] Univ Hosp Leuven, Dept Surg Oncol, B-3000 Louvain, Belgium.
Keywords: catheter lock; catheter-related infection; equipment failure; heparin; sodium chloride;catheter lock; catheter-related infection; equipment failure; heparin; sodium chloride
Document URI: http://hdl.handle.net/1942/15459
ISSN: 0923-7534
e-ISSN: 1569-8041
DOI: 10.1093/annonc/mdt114
ISI #: 000321881600027
Category: A1
Type: Journal Contribution
Validations: ecoom 2014
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
12.pdf174.37 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

44
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

56
checked on May 9, 2024

Page view(s)

68
checked on Sep 7, 2022

Download(s)

92
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.