Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/1581
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | BenMoussa, A. | - |
dc.contributor.author | Theissen, A. | - |
dc.contributor.author | Scholze, F. | - |
dc.contributor.author | Hochedez, JF. | - |
dc.contributor.author | Schule, F. | - |
dc.contributor.author | Schmutz, U. | - |
dc.contributor.author | HAENEN, Ken | - |
dc.contributor.author | Stockman, Y. | - |
dc.contributor.author | Soltani, A. | - |
dc.contributor.author | McMullin, D. | - |
dc.contributor.author | Vest, RE. | - |
dc.contributor.author | Kroth, U. | - |
dc.contributor.author | Laubis, C. | - |
dc.contributor.author | Richter, M. | - |
dc.contributor.author | MORTET, Vincent | - |
dc.contributor.author | Gissot, S. | - |
dc.contributor.author | Delouille, V. | - |
dc.contributor.author | Dominique, M. | - |
dc.contributor.author | Koller, S. | - |
dc.contributor.author | Halain, JP | - |
dc.contributor.author | REMES, Zdenek | - |
dc.contributor.author | PETERSEN, Rainer | - |
dc.contributor.author | D'OLIESLAEGER, Marc | - |
dc.contributor.author | Defise, JM. | - |
dc.date.accessioned | 2007-06-05T11:57:16Z | - |
dc.date.available | 2007-06-05T11:57:16Z | - |
dc.date.issued | 2006 | - |
dc.identifier.citation | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS, 568(1). p. 398--405 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | http://hdl.handle.net/1942/1581 | - |
dc.description.abstract | We report on experimental results with photodetectors made of diamond. the Large Yield Radiometer (LYRA), will use such detectors for the first time for a solar physics space instrument. A (LYRA) set of measurement campaigns was carried out to obtain their XUV-to-VIS characterization (responsivity, linearity, stability, homogeneity). The responsivity has been measured from the XUV to the NIR, in the wavelength range 1–1127 nm (i.e. 1240–1.1 eV). The diamond detectors exhibit a photoresponse varying in the 40–75 mA/W range at 7 nm and demonstrate a visible rejection ratio (200 versus 500 nm) larger than four orders of magnitude. We show that diamond photodetectors are sensitive sensors for VUV photons, stable within a few percent, with a good linearity and moderate homogeneity. | - |
dc.language.iso | en | - |
dc.publisher | Elsevier | - |
dc.subject.other | UV detectors; Diamond; Solar-blind photodetector | - |
dc.title | Performance of diamond detectors for VUV applications | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 405 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 398- | - |
dc.identifier.volume | 568 | - |
local.bibliographicCitation.jcat | A1 | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.bibliographicCitation.oldjcat | A1 | - |
dc.identifier.doi | 10.1016/j.nima.2006.06.007 | - |
dc.identifier.isi | 000242742300065 | - |
item.accessRights | Closed Access | - |
item.fulltext | No Fulltext | - |
item.validation | ecoom 2008 | - |
item.contributor | BenMoussa, A. | - |
item.contributor | Theissen, A. | - |
item.contributor | Scholze, F. | - |
item.contributor | Hochedez, JF. | - |
item.contributor | Schule, F. | - |
item.contributor | Schmutz, U. | - |
item.contributor | HAENEN, Ken | - |
item.contributor | Stockman, Y. | - |
item.contributor | Soltani, A. | - |
item.contributor | McMullin, D. | - |
item.contributor | Vest, RE. | - |
item.contributor | Kroth, U. | - |
item.contributor | Laubis, C. | - |
item.contributor | Richter, M. | - |
item.contributor | MORTET, Vincent | - |
item.contributor | Gissot, S. | - |
item.contributor | Delouille, V. | - |
item.contributor | Dominique, M. | - |
item.contributor | Koller, S. | - |
item.contributor | Halain, JP | - |
item.contributor | REMES, Zdenek | - |
item.contributor | PETERSEN, Rainer | - |
item.contributor | D'OLIESLAEGER, Marc | - |
item.contributor | Defise, JM. | - |
item.fullcitation | BenMoussa, A.; Theissen, A.; Scholze, F.; Hochedez, JF.; Schule, F.; Schmutz, U.; HAENEN, Ken; Stockman, Y.; Soltani, A.; McMullin, D.; Vest, RE.; Kroth, U.; Laubis, C.; Richter, M.; MORTET, Vincent; Gissot, S.; Delouille, V.; Dominique, M.; Koller, S.; Halain, JP; REMES, Zdenek; PETERSEN, Rainer; D'OLIESLAEGER, Marc & Defise, JM. (2006) Performance of diamond detectors for VUV applications. In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS, 568(1). p. 398--405. | - |
crisitem.journal.issn | 0168-9002 | - |
crisitem.journal.eissn | 1872-9576 | - |
Appears in Collections: | Research publications |
SCOPUSTM
Citations
32
checked on Sep 30, 2025
WEB OF SCIENCETM
Citations
31
checked on Oct 4, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.