Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/15843
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Schusser, S. | - |
dc.contributor.author | Poghossian, A. | - |
dc.contributor.author | Baecker, M. | - |
dc.contributor.author | Leinhos, M. | - |
dc.contributor.author | WAGNER, Patrick | - |
dc.contributor.author | Schoening, M. J. | - |
dc.date.accessioned | 2013-10-23T13:18:01Z | - |
dc.date.available | 2013-10-23T13:18:01Z | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | SENSORS AND ACTUATORS B-CHEMICAL, 187, p. 2-7 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://hdl.handle.net/1942/15843 | - |
dc.description.abstract | In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta2O5-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance-voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor. (C) 2012 Elsevier B. V. All rights reserved. | - |
dc.description.sponsorship | This particular study was financed through generous contributions of the European Union (through Interreg IV-A) and the government of North Rhine-Westphalia (Germany) in the frame of BioMIMedics. | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject.other | Chemistry, Analytical; Electrochemistry; Instruments & Instrumentation | - |
dc.subject.other | Field-effect sensor; (Bio)degradation; Poly(D,L-lacticacid); Real-time monitoring; C-V method; Impedance spectroscopy | - |
dc.title | Characterization of biodegradable polymers with capacitive field-effect sensors | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 7 | - |
dc.identifier.spage | 2 | - |
dc.identifier.volume | 187 | - |
local.format.pages | 6 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | [Schusser, S.; Poghossian, A.; Baecker, M.; Leinhos, M.; Schoening, M. J.] Aachen Univ Appl Sci, Inst Nano & Biotechnol INB, D-52428 Julich, Germany. [Schusser, S.; Poghossian, A.; Baecker, M.; Leinhos, M.; Schoening, M. J.] Forschungszentrum Julich, Peter Grunberg Inst PGI 8, D-52525 Julich, Germany. [Wagner, P.] Hasselt Univ, Inst Mat Res IMO, B-3590 Diepenbeek, Belgium. a.poghossian@fz-juelich.de | - |
local.publisher.place | LAUSANNE | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.identifier.doi | 10.1016/j.snb.2012.07.099 | - |
dc.identifier.isi | 000324298300002 | - |
item.fulltext | With Fulltext | - |
item.contributor | Schusser, S. | - |
item.contributor | Poghossian, A. | - |
item.contributor | Baecker, M. | - |
item.contributor | Leinhos, M. | - |
item.contributor | WAGNER, Patrick | - |
item.contributor | Schoening, M. J. | - |
item.validation | ecoom 2014 | - |
item.fullcitation | Schusser, S.; Poghossian, A.; Baecker, M.; Leinhos, M.; WAGNER, Patrick & Schoening, M. J. (2013) Characterization of biodegradable polymers with capacitive field-effect sensors. In: SENSORS AND ACTUATORS B-CHEMICAL, 187, p. 2-7. | - |
item.accessRights | Restricted Access | - |
crisitem.journal.eissn | 0925-4005 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
schusser 1.pdf Restricted Access | Published version | 786.75 kB | Adobe PDF | View/Open Request a copy |
SCOPUSTM
Citations
9
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
13
checked on Oct 14, 2024
Page view(s)
126
checked on Sep 7, 2022
Download(s)
112
checked on Sep 7, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.