Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/16153
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGeerets, Bram-
dc.contributor.authorPEETERS, Marloes-
dc.contributor.authorVAN GRINSVEN, Bart-
dc.contributor.authorBERS, Karolien-
dc.contributor.authorDE CEUNINCK, Ward-
dc.contributor.authorWAGNER, Patrick-
dc.date.accessioned2014-01-24T12:20:59Z-
dc.date.available2014-01-24T12:20:59Z-
dc.date.issued2013-
dc.identifier.citationSENSORS, 13 (7), p. 9148-9159-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/1942/16153-
dc.description.abstractIn previous work, the novel heat-transfer method (HTM) for the detection of small molecules with Molecularly Imprinted Polymers (MIP)-type receptors was presented. In this study we focus on optimization of this sensor performance, with as final aim to lower the detection limit by reducing the noise level. It was determined that the noise originates foremost from the power supply, which can be controlled by varying the PID parameters. Therefore, the effect of the individual parameters was evaluated by tuning P, I and D separately at a temperature of 37 degrees C, giving a first indication of the optimal configuration. Next, a temperature profile was programmed and the standard deviation of the heat-transfer resistance over the entire regime was studied for a set of parameters. The optimal configuration, P1-I6-D0, reduced the noise level with nearly a factor of three compared to the original parameters of P10-I5-D0. With the optimized settings, the detection of L-nicotine in buffer solutions was studied and the detection limit improved significantly from 100 nM to 35 nM. Summarizing, optimization of the PID parameters and thereby improving the detection limit is a key parameter for first applications of the HTM-method for MIP receptors in analytical research.-
dc.description.sponsorshipThis work is supported by the Life-Science Initiative of the Province of Limburg, by the Special Research Funds of Hasselt University, the Methusalem Nano Antwerp-Hasselt, the European Funds for Regional Development-MicroBioMed and the Research Foundation Flanders FWO project G.0B62.13N (Exploration of heat-transfer effects for bio- and chemosensors). The authors also would like to thank Thomas Cleij, Huguette Penxten, Johan Soogen, Christel Willems, Johnny Baccus, Lieven De Winter, Jan Mertens, and Andries Van Genechten for technical assistance and stimulating scientific discussions.-
dc.language.isoen-
dc.subject.otherheat-transfer method (HTM); molecularly imprinted polymers (MIPs); L-nicotine; PID parameters-
dc.titleOptimizing the Thermal Read-Out Technique for MIP-Based Biomimetic Sensors: Towards Nanomolar Detection Limits-
dc.typeJournal Contribution-
dc.identifier.epage9159-
dc.identifier.issue7-
dc.identifier.spage9148-
dc.identifier.volume13-
local.bibliographicCitation.jcatA1-
dc.description.notesPeeters, M (reprint author), Hasselt Univ, Inst Mat Res, Wetenschapspk 1, B-3590 Diepenbeek, Belgium. bram.geerets@student.uhasselt.be; marloes.peeters@uhasselt.be; bart.vangrinsven@uhasselt.be; karolien.bers@uhasselt.be; ward.deceuninck@uhasselt.be; patrick.wagner@uhasselt.be-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.3390/s130709148-
dc.identifier.isi000328612800059-
item.validationecoom 2015-
item.contributorGeerets, Bram-
item.contributorPEETERS, Marloes-
item.contributorVAN GRINSVEN, Bart-
item.contributorBERS, Karolien-
item.contributorDE CEUNINCK, Ward-
item.contributorWAGNER, Patrick-
item.accessRightsOpen Access-
item.fullcitationGeerets, Bram; PEETERS, Marloes; VAN GRINSVEN, Bart; BERS, Karolien; DE CEUNINCK, Ward & WAGNER, Patrick (2013) Optimizing the Thermal Read-Out Technique for MIP-Based Biomimetic Sensors: Towards Nanomolar Detection Limits. In: SENSORS, 13 (7), p. 9148-9159.-
item.fulltextWith Fulltext-
crisitem.journal.eissn1424-8220-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
geerets 1.pdfPublished version795.44 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

17
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

21
checked on Apr 30, 2024

Page view(s)

88
checked on Sep 7, 2022

Download(s)

116
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.