dc.description.abstractBackground: Atrial fibrillation is very common in people aged 65 or older. This condition increases the risk of death, congestive heart failure and thromboembolic conditions. Many patients with atrial fibrillation are asymptomatic and a cerebrovascular accident (CVA) is often the first clinical presentation. Guidelines concerning the prevention of CVA recommend monitoring the heart rate in patients aged 65 or older. Recently, the MyDiagnostick (Applied Biomedical Systems BV, Maastricht, The Netherlands) was introduced as a new screening tool which might serve as an alternative for the less accurate pulse palpation. This study was designed to explore the diagnostic accuracy of the MyDiagnostick for the detection of atrial fibrillation. Methods: A phase II diagnostic accuracy study in a convenience sample of 191 subjects recruited in primary care. The majority of participants were patients with a known history of atrial fibrillation (n = 161). Readings of the MyDiagnostick were compared with electrocardiographic recordings. Sensitivity and specificity and their 95% confidence interval were calculated using 2x2 tables. Results: A prevalence of 54% for an atrial fibrillation rhythm was found in the study population at the moment of the study. A combination of three measurements with the MyDiagnostick for each patient showed a sensitivity of 94% (95% CI 87 - 98) and a specificity of 93% (95% CI 85 - 97). Conclusion: The MyDiagnostick is an easy-to-use device that showed a good diagnostic accuracy with a high sensitivity and specificity for atrial fibrillation in a convenience sample in primary care. Future research is needed to determine the place of the MyDiagnostick in possible screening or case-finding strategies for atrial fibrillation.-
dc.language.isoen-
dc.publisherBIOMED CENTRAL LTD-
dc.rights© 2014 Vaes et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.-
dc.subject.otherAtrial fibrillation; Sensitivity and specificity; MyDiagnostick; Primary care-
dc.subject.otheratrial fibrillation; sensitivity and specificity; MyDiagnostick; primary care-
dc.titleThe diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care-
dc.typeJournal Contribution-
dc.identifier.volume15-
local.format.pages7-
local.format.pages7-
local.bibliographicCitation.jcatA1-
dc.description.notes[Vaes, Bert; Stalpaert, Silke; Tavernier, Karen; Thaels, Britt; Lapeire, Daphne; Degryse, Jan] Katholieke Univ Leuven, Dept Gen Practice, Louvain, Belgium. [Vaes, Bert; Degryse, Jan] Catholic Univ Louvain, Inst Hlth & Soc, B-1200 Brussels, Belgium. [Mullens, Wilfried] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium. [Mullens, Wilfried] Hasselt Univ, Fac Med & Life Sci, Biomed Res Inst, Diepenbeek, Belgium. Bert.Vaes@uclouvain.be-
local.publisher.placeLONDON-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1186/1471-2296-15-113-
dc.identifier.isi000338316000002-
item.accessRightsOpen Access-
item.validationecoom 2015-
item.contributorVaes, Bert-
item.contributorStalpaert, Silke-
item.contributorTavernier, Karen-
item.contributorThaels, Britt-
item.contributorLapeire, Daphne-
item.contributorMULLENS, Wilfried-
item.contributorDegryse, Jan-
item.fulltextWith Fulltext-
item.fullcitationVaes, Bert; Stalpaert, Silke; Tavernier, Karen; Thaels, Britt; Lapeire, Daphne; MULLENS, Wilfried & Degryse, Jan (2014) The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care. In: BMC FAMILY PRACTICE, 15.-
crisitem.journal.issn1471-2296-
crisitem.journal.eissn1471-2296-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
1471-2296-15-113.pdfPublished version430.8 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

35
checked on Sep 7, 2020

WEB OF SCIENCETM
Citations

56
checked on Jul 11, 2024

Page view(s)

132
checked on Jul 22, 2022

Download(s)

172
checked on Jul 22, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.