Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/18046
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | HUANG, Yanru | - |
dc.contributor.author | Van Dessel, Jeroen | - |
dc.contributor.author | Depypere, Maarten | - |
dc.contributor.author | EzEldeen, Mostafa | - |
dc.contributor.author | Iliescu, Alexandru Andrei | - |
dc.contributor.author | Dos Santos, Emanuela | - |
dc.contributor.author | LAMBRICHTS, Ivo | - |
dc.contributor.author | LIANG, Xin | - |
dc.contributor.author | Jacobs, Reinhilde | - |
dc.date.accessioned | 2014-12-19T14:34:52Z | - |
dc.date.available | 2014-12-19T14:34:52Z | - |
dc.date.issued | 2014 | - |
dc.identifier.citation | BONE RESEARCH, 2 | - |
dc.identifier.issn | 2095-4700 | - |
dc.identifier.uri | http://hdl.handle.net/1942/18046 | - |
dc.description.abstract | Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mu m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (similar to 6 mu m) to obtain high contrast 2D images. By using CT An imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb. Th and Tb. Sp, lower BV/TV and Tb.N were found on CBCT images (P<0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation. | - |
dc.description.sponsorship | We are grateful to Jeanine Santermans and Marc Jans for their technical assistance. The study was supported by grants from the Interfaculty Council for Development Co-operation (IRO), KU Leuven, Belgium. The authors declare no potential conflicts of interest in this study. | - |
dc.language.iso | en | - |
dc.publisher | NATURE PUBLISHING GROUP | - |
dc.rights | © 2014 Sichuan University All rights reserved 2095-4700/14 | - |
dc.title | Validating cone-beam computed tomography for peri-implant bone morphometric analysis | - |
dc.type | Journal Contribution | - |
dc.identifier.volume | 2 | - |
local.format.pages | 7 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | [Huang, Yan; Van Dessel, Jeroen; EzEldeen, Mostafa; Jacobs, Reinhilde] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium. [Huang, Yan; Van Dessel, Jeroen; EzEldeen, Mostafa; Jacobs, Reinhilde] Univ Hosp Leuven, Leuven, Belgium. [Huang, Yan] Sichuan Univ, West China Hosp Stomatol, State Key Lab Oral Dis, Chengdu 610064, Peoples R China. [Depypere, Maarten] Katholieke Univ Leuven, ESAT PSI, Leuven, Belgium. [Iliescu, Alexandru Andrei] UMF Craiova, Fac Dent, Craiova, Romania. [Dos Santos, Emanuela] Pontificia Univ Catolica Parana, Sch Dent, Curitiba, Parana, Brazil. [Lambrichts, Ivo] Hasselt Univ, Biomed Res Inst, Diepenbeek, Belgium. [Liang, Xin] Dalian Med Univ, Sch Stomatol, Dalian, Peoples R China. | - |
local.publisher.place | LONDON | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.identifier.doi | 10.1038/boneres.2014.10 | - |
dc.identifier.isi | 000344998000001 | - |
item.fullcitation | HUANG, Yanru; Van Dessel, Jeroen; Depypere, Maarten; EzEldeen, Mostafa; Iliescu, Alexandru Andrei; Dos Santos, Emanuela; LAMBRICHTS, Ivo; LIANG, Xin & Jacobs, Reinhilde (2014) Validating cone-beam computed tomography for peri-implant bone morphometric analysis. In: BONE RESEARCH, 2. | - |
item.fulltext | With Fulltext | - |
item.accessRights | Open Access | - |
item.validation | ecoom 2015 | - |
item.contributor | HUANG, Yanru | - |
item.contributor | Van Dessel, Jeroen | - |
item.contributor | Depypere, Maarten | - |
item.contributor | EzEldeen, Mostafa | - |
item.contributor | Iliescu, Alexandru Andrei | - |
item.contributor | Dos Santos, Emanuela | - |
item.contributor | LAMBRICHTS, Ivo | - |
item.contributor | LIANG, Xin | - |
item.contributor | Jacobs, Reinhilde | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
boneres201410.pdf | 1.4 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
17
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
27
checked on Sep 12, 2024
Page view(s)
44
checked on May 19, 2022
Download(s)
76
checked on May 19, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.