dc.description.abstractAdvancements made over the past decades in both molecular imaging and radiotherapy planning and delivery have enabled studies that explore the efficacy of heterogeneous radiation treatment ("dose painting'') of solid cancers based on biological information provided by different imaging modalities. In addition to clinical trials, preclinical studies may help contribute to identifying promising dose painting strategies. The goal of this current study was twofold: to develop a reproducible positioning and set-up verification protocol for a rat tumor model to be imaged and treated on a clinical platform, and to assess the dosimetric accuracy of dose planning and delivery for both uniform and positron emission tomography-computed tomography (PETCT) based heterogeneous dose distributions. We employed a syngeneic rat rhabdomyosarcoma model, which was irradiated by volumetric modulated arc therapy (VMAT) with uniform or heterogeneous 6 MV photon dose distributions. Mean dose to the gross tumor volume (GTV) as a whole was kept at 12 Gy for all treatment arms. For the nonuniform plans, the dose was redistributed to treat the 30% of the GTV representing the biological target volume (BTV) with a dose 40% higher than the rest of the GTV (GTV - BTV) (similar to 15 Gy was delivered to the BTV vs. similar to 10.7 Gy was delivered to the GTV - BTV). Cone beam computed tomography (CBCT) images acquired for each rat prior to irradiation were used to correctly reposition the tumor and calculate the delivered 3D dose. Film quality assurance was performed using a water-equivalent rat phantom. A comparison between CT or CBCT doses and film measurements resulted in passing rates >98% with a gamma criterion of 3%/2 mm using 2D dose images. Moreover, between the CT and CBCT calculated doses for both uniform and heterogeneous plans, we observed maximum differences of <2% for mean dose to the tumor and mean dose to the biological target volumes. In conclusion, we have developed a robust method for dose painting in a rat tumor model on a clinical platform, with a high accuracy achieved in the delivery of complex dose distributions. Our work demonstrates the technical feasibility of this approach and enables future investigations on the therapeutic effect of preclinical dose painting strategies using a state-of-the-art clinical platform. (C) 2015 by Radiation Research Society-
dc.description.sponsorshipThe authors acknowledge financial support from Varian Medical Systems (Cooperation Agreement MAASTRO-002), : CTMM the Center for Translational Molecular Medicine (www.ctmm.nl) project AIRFORCE number 03O-103; EU 6th and 7th Framework Programme project METOXIA number 222741, project ARTFORCE number 257144; IVA Interreg project EuroCAT www.eurocat.info number EMR INT4.1.2.-2009-04/049; Kankeronderzoekfonds Limburg from the Health Foundation Limburg and the Dutch Cancer Society (KWF UM 2011-5020, KWF UM 2009-4454).-
dc.language.isoen-
dc.publisherRADIATION RESEARCH SOC-
dc.rights© 2015 by Radiation Research Society. All rights of reproduction in any form reserved-
dc.titleWhat Level of Accuracy Is Achievable for Preclinical Dose Painting Studies on a Clinical Irradiation Platform?-
dc.typeJournal Contribution-
dc.identifier.epage510-
dc.identifier.issue5-
dc.identifier.spage501-
dc.identifier.volume183-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notes[Trani, Daniela; Reniers, Brigitte; Persoon, Lucas; Podesta, Mark; Nalbantov, Georgi; Leijenaar, Ralph T. H.; Granzier, Marlies; Yaromina, Ala; Dubois, Ludwig; Verhaegen, Frank; Lambin, Philippe] Maastricht Univ, Maastricht Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, Med Ctr, NL-6229 ET Maastricht, Netherlands. [Reniers, Brigitte] Hasselt Univ, CMK, Res Grp NuTeC, B-3590 Diepenbeek, Belgium. [Verhaegen, Frank] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ H3G 1A4, Canada.Editor's note. The online version of this article (DOI: 10.1667/RR13933.1) contains supplementary information that is available to all authorized users.-
local.publisher.placeLAWRENCE-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1667/RR13933.1-
dc.identifier.isi000354972500003-
item.validationecoom 2016-
item.accessRightsRestricted Access-
item.fullcitationTrani, Daniela; RENIERS, Brigitte; Persoon, Lucas; Podesta, Mark; Nalbantov, Georgi; Leijenaar, Ralph T. H.; Granzier, Marlies; Yaromina, Ala; Dubois, Ludwig; Verhaegen, Frank & Lambin, Philippe (2015) What Level of Accuracy Is Achievable for Preclinical Dose Painting Studies on a Clinical Irradiation Platform?. In: RADIATION RESEARCH, 183 (5), p. 501-510.-
item.fulltextWith Fulltext-
item.contributorTrani, Daniela-
item.contributorRENIERS, Brigitte-
item.contributorPersoon, Lucas-
item.contributorPodesta, Mark-
item.contributorNalbantov, Georgi-
item.contributorLeijenaar, Ralph T. H.-
item.contributorGranzier, Marlies-
item.contributorYaromina, Ala-
item.contributorDubois, Ludwig-
item.contributorVerhaegen, Frank-
item.contributorLambin, Philippe-
crisitem.journal.issn0033-7587-
crisitem.journal.eissn1938-5404-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
rr13933%2E1.pdf
  Restricted Access
1.03 MBAdobe PDFView/Open    Request a copy
Show simple item record

SCOPUSTM   
Citations

5
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

7
checked on May 8, 2024

Page view(s)

54
checked on Sep 6, 2022

Download(s)

42
checked on Sep 6, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.