Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/19156
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLEMMENS, Ryanne-
dc.contributor.authorSeelen, Henk A. M.-
dc.contributor.authorTIMMERMANS, Annick-
dc.contributor.authorSchnackers, Marlous L. A. P.-
dc.contributor.authorEerden, Annet-
dc.contributor.authorSmeets, Rob J. E. M.-
dc.contributor.authorJanssen-Potten, Yvonne J. M.-
dc.date.accessioned2015-09-15T10:29:15Z-
dc.date.available2015-09-15T10:29:15Z-
dc.date.issued2015-
dc.identifier.citationIEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 23 (4), p. 581-590-
dc.identifier.issn1534-4320-
dc.identifier.urihttp://hdl.handle.net/1942/19156-
dc.description.abstractNeurological patients often encounter arm-hand problems in daily life. Bodily worn sensors may be used to assess actual performance by quantifying specific movement patterns associated with specific activities. However, signal reliability during activities of daily living should be determined first. The aim is to determine to what extent standardized arm-hand skill performance of both healthy adults and healthy children can be recorded reliably using a combination of multiple sensor devices. Thirty adults (aged > 50 years) and thirty-two children (aged between 6-18 years) performed the activities drinking, eating and combing five times in a standardized setting. Sensor devices, each containing a triaxial accelerometer, gyroscope and magnetometer were attached to the arms, hands and trunk of the participants. Within-subject and between-subject reliability of the signal patterns amongst skill repetitions was determined by calculating Intraclass Correlation Coefficients (ICCs). Median reliability was good to very good for all activities performed (both within and between subjects). Regarding within-subject reliability (instruction-condition), median ICCs ranged between 0.76-0.90 and 0.68-0.92 for the adults and children, respectively. For between-subject reliability (instruction-condition), median ICCs ranged 0.75-0.86 and 0.61-0.90 for the adults and children, respectively. It can be concluded that the above-mentioned sensor system can reliably record activities of daily living in a standardized setting.-
dc.description.sponsorshipThis paper was supported by Adelante, Centre of Expertise in Rehabilitation and Audiology, Hoensbroek, the Netherlands.-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subject.otherActivities of daily living (ADL); outcome assessment reliability; reproducibility of results; sensor; upper extremity-
dc.subject.otheractivities of daily living; outcome assessment; reliability; reproducibility of results; sensor; upper extremity-
dc.titleTo What Extent Can Arm-Hand Skill Performance-of Both Healthy Adults and Children-Be Recorded Reliably Using Multiple Bodily Worn Sensor Devices?-
dc.typeJournal Contribution-
dc.identifier.epage590-
dc.identifier.issue4-
dc.identifier.spage581-
dc.identifier.volume23-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesThis article has been accepted for publication in a future issue of this journal, but has not been fully edited. Content may change prior to final publication.-
local.publisher.placePISCATAWAY-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1109/TNSRE.2015.2396082-
dc.identifier.isi000357596500006-
dc.identifier.urlhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7031937-
item.accessRightsOpen Access-
item.fullcitationLEMMENS, Ryanne; Seelen, Henk A. M.; TIMMERMANS, Annick; Schnackers, Marlous L. A. P.; Eerden, Annet; Smeets, Rob J. E. M. & Janssen-Potten, Yvonne J. M. (2015) To What Extent Can Arm-Hand Skill Performance-of Both Healthy Adults and Children-Be Recorded Reliably Using Multiple Bodily Worn Sensor Devices?. In: IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 23 (4), p. 581-590.-
item.fulltextWith Fulltext-
item.validationecoom 2016-
item.contributorLEMMENS, Ryanne-
item.contributorSeelen, Henk A. M.-
item.contributorTIMMERMANS, Annick-
item.contributorSchnackers, Marlous L. A. P.-
item.contributorEerden, Annet-
item.contributorSmeets, Rob J. E. M.-
item.contributorJanssen-Potten, Yvonne J. M.-
crisitem.journal.issn1534-4320-
crisitem.journal.eissn1558-0210-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
fulltext.pdf330.62 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

4
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

4
checked on May 16, 2024

Page view(s)

18
checked on Sep 7, 2022

Download(s)

162
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.