Issue Date: | 2015 | Publisher: | WILEY-BLACKWELL | Source: | SKIN RESEARCH AND TECHNOLOGY, 21 (3), p. 302-312 | Abstract: | Background/purposeThe water content in burn scars, the parameter of stratum corneum water holding capacity, is an important feature in evaluation of biophysical properties of scars. Nevertheless, quantifiying this parameter is a challenge. In this study, the reliability of repeated water content measurements with Corneometer CM825((R)) on (burn) scars was investigated. MethodsIntra-observer reliability, inter-observer reliability and day-by-day variability were examined on 30 scars by means of intra-class correlation coefficient (ICC) and within-subject coefficient of variation (WSCV). Bland-Altman plots with 95% limits of agreement' were constructed. ResultsResults revealed excellent ICC values (ICCintra=0.985; ICCinter=0.984) with relatively low WSCV (WSCVintra=6.3%; WSCVinter=10.6%) for respectively intra- and inter-observer reliability. However, the Bland-Altman plot showed that more than 5% of differences were expected to exceed 4a.u., the limit of what has been defined as a clinically acceptable difference. Results for day-by-day variability showed good ICC value (ICCday-by-day=0.849) and higher WSCV (WSCVday-by-day=20.5%). ConclusionThe Corneometer CM825((R)) is an objective and sensitive instrument for water content measurements. On the basis of our results, we concluded that the instrument can be used in clinical trials, but only under very strict conditions with standardized test protocol, preferably in combination with the evaluation of other physiological parameters. | Notes: | [Anthonissen, M.; Peeters, R.; Van den Kerckhove, E.] Katholieke Univ Leuven, Dept Rehabil Sci, B-3001 Leuven, Belgium. [Anthonissen, M.; Van den Kerckhove, E.] UZ Leuven, Dept Phys Med & Rehabil, Leuven, Belgium. [Anthonissen, M.; Van Brussel, M.; Van den Kerckhove, E.] UZ Leuven, Burns Ctr, Leuven, Belgium. [Anthonissen, M.; Moortgat, P.] OSCARE Org Burns, Scar After Care & Res, Antwerp, Belgium. [Daly, D.] Katholieke Univ Leuven, Dept Kinesiol, B-3001 Leuven, Belgium. [Van Brussel, M.] UZ Leuven, Dept Plast & Reconstruct Surg, Leuven, Belgium. [Fieuws, S.] Katholieke Univ Leuven, I Biostat, B-3001 Leuven, Belgium. [Fieuws, S.] Hasselt Univ, Leuven, Belgium. [Flour, M.] UZ Leuven, Dept Dermatol, Leuven, Belgium. [Van den Kerckhove, E.] AZ Maastricht, Dept Plast Surg, Maastricht, Netherlands. | Keywords: | burn scar; reliability; water content; water holding capacity; stratum corneum;burn scar; reliability; water content; water holding capacity; stratum corneum | Document URI: | http://hdl.handle.net/1942/19894 | ISSN: | 0909-752X | e-ISSN: | 1600-0846 | DOI: | 10.1111/srt.12193 | ISI #: | 000357945700008 | Rights: | © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd | Category: | A1 | Type: | Journal Contribution | Validations: | ecoom 2016 |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
anthonissen 1.pdf Restricted Access | Published version | 441.98 kB | Adobe PDF | View/Open Request a copy |
SCOPUSTM
Citations
9
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
21
checked on Apr 23, 2024
Page view(s)
64
checked on Jun 9, 2022
Download(s)
62
checked on Jun 9, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.