Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/20668
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGoossens, G. A.-
dc.contributor.authorDe Waele, Y.-
dc.contributor.authorJérôme, M.-
dc.contributor.authorFIEUWS, Steffen-
dc.contributor.authorJanssens, C.-
dc.contributor.authorStas, M.-
dc.contributor.authorMoons, Philip-
dc.date.accessioned2016-02-17T08:57:43Z-
dc.date.available2016-02-17T08:57:43Z-
dc.date.issued2016-
dc.identifier.citationSUPPORTIVE CARE IN CANCER, 24 (2), p. 755-761-
dc.identifier.issn0941-4355-
dc.identifier.urihttp://hdl.handle.net/1942/20668-
dc.description.abstractIntravenous catheters are used for the administration of intravenous therapy and for blood sampling. These devices are considered as well-functioning if both the injection and aspiration are easy. Malfunction is frequently observed and usually vaguely described as occlusion. We developed the CINAS, the Catheter Injection and Aspiration scheme. The CINAS is a catheter function classification tool, which classifies both the injection and the aspiration ability in a uniform way. Each CINAS class consists of a combination of an injection (IN) and an aspiration (AS) code: e.g. IN1AS1 is the CINAS class for a well-functioning catheter. In this series, we aimed to determine the accuracy of the CINAS class reported by nurses, after minimal training, versus a trained researcher, acting as a reference standard. Catheter function was assessed during a standard blood sampling procedure through a totally implantable venous access device in a convenience sample of 150 oncology patients. One nurse researcher and 111 oncology nurses both scored the catheter function according to the CINAS classification scheme, independently. Concordance between the scores was calculated. For the 140 catheters scored as well-functioning (IN1AS1 score) by the researcher, 139 or 99.3 % (95 % confidence interval (CI) 96.1-99.9 %) were scored correctly by the nurse participants. Nine out of ten or 90 % (95 % CI 55.5-98.3 %) of malfunctioning catheters (researcher scores different from IN1AS1) were also identified as malfunctioning by the nurse participants and received exactly the same CINAS score in eight cases (80 %, 95 % CI 44.4-97.5 %). The overall accuracy of the CINAS scored by the nurse participants versus the researcher is (139 + 9)/150 or 98.7 % (95 % CI 95.3-99.8 %). Nurse participants were able to classify the catheter function of totally implantable venous access devices with the CINAS accurately after a brief explanation about the classification options.-
dc.language.isoen-
dc.publisherSPRINGER-
dc.rights© Springer-Verlag Berlin Heidelberg 2015-
dc.subject.othervascular access devices; equipment failure; malfunction; classification tool; CINAS-
dc.subject.otherVascular access devices; Equipment failure; Malfunction; Classification tool; CINAS-
dc.titleDiagnostic accuracy of the Catheter Injection and Aspiration (CINAS) classification for assessing the function of totally implantable venous access devices-
dc.typeJournal Contribution-
dc.identifier.epage761-
dc.identifier.issue2-
dc.identifier.spage755-
dc.identifier.volume24-
local.format.pages7-
local.bibliographicCitation.jcatA1-
dc.description.notes[Goossens, G. A.; Jerome, M.; Janssens, C.] Univ Hosp Leuven, Nursing Ctr Excellence, Leuven, Belgium. [Goossens, G. A.; Moons, P.] Katholieke Univ Leuven, Dept Publ Hlth & Primary Care, B-3000 Leuven, Belgium. [De Waele, Y.] Univ Antwerp Hosp, Dept Orthopaed Surg, B-2650 Edegem, Belgium. [Fieuws, S.] Katholieke Univ Leuven, Interuniv Ctr Biostat & Stat Bioinformat, B-3000 Leuven, Belgium. [Fieuws, S.] Univ Hasselt, B-3000 Leuven, Belgium. [Stas, M.] Univ Hosp Leuven, Dept Surg Oncol, Leuven, Belgium. [Moons, P.] Copenhagen Univ Hosp, Ctr Heart, DK-2100 Copenhagen, Denmark. [Moons, P.] Univ Gothenburg, Inst Hlth & Care Sci, Gothenburg, Sweden.-
local.publisher.placeNEW YORK-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1007/s00520-015-2839-x-
dc.identifier.isi000367458200029-
item.fullcitationGoossens, G. A.; De Waele, Y.; Jérôme, M.; FIEUWS, Steffen; Janssens, C.; Stas, M. & Moons, Philip (2016) Diagnostic accuracy of the Catheter Injection and Aspiration (CINAS) classification for assessing the function of totally implantable venous access devices. In: SUPPORTIVE CARE IN CANCER, 24 (2), p. 755-761.-
item.contributorGoossens, G. A.-
item.contributorDe Waele, Y.-
item.contributorJérôme, M.-
item.contributorFIEUWS, Steffen-
item.contributorJanssens, C.-
item.contributorStas, M.-
item.contributorMoons, Philip-
item.accessRightsRestricted Access-
item.validationecoom 2017-
item.fulltextWith Fulltext-
crisitem.journal.issn0941-4355-
crisitem.journal.eissn1433-7339-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
art%3A10.1007%2Fs00520-015-2839-x.pdf
  Restricted Access
Published version535.43 kBAdobe PDFView/Open    Request a copy
Show simple item record

SCOPUSTM   
Citations

6
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

14
checked on Aug 3, 2024

Page view(s)

86
checked on Sep 7, 2022

Download(s)

66
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.