Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/2155
Title: Biologic response of immediately versus delayed loaded implants supporting ill-fitting prostheses: An animal study
Authors: Vrielinck, L.
Abe, Y.
Schepers, S.
Naert, I.
LAMBRICHTS, Ivo 
POLITIS, Constantinus 
Issue Date: 2005
Publisher: BLACKWELL PUBLISHING
Source: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 7(3). p. 150-158
Abstract: Background: Computer-assisted preoperative implant planning and transfer toward the patient allow the production of a prosthesis prior to surgery. This implies that the prosthesis can be installed immediately following implant insertion. Am inherent disadvantage of this is a cumulated error, which can lead to prosthesis misfit owing to topographic deviations of the planned versus the installed implants. Purpose: The aim of this study was to determine whether prosthesis misfit is compromising the osseointegration of immediately versus delayed loaded implants and whether freshly installed implants adapt to the prosthesis. Materials and Methods: In each of five New Zealand White rabbits, two experimental conditions were compared. One tibia harbored the so-called test implant, which originally showed a vertical misfit of about 500 mu m with the prosthesis to which it was tightened immediately after implant installation. The control implant was installed in the other tibia and was allowed to heal during 9 weeks before the prosthesis with the vertical misfit of about 500 Vim was connected to it. The prostheses were left in place for 12 weeks, after which the animals were sacrificed. Results: All implants healed uneventfully. There were no statistically significant differences between the biologic responses of test and control implants. With a three-dimensional laser scanner, significantly more displacement of the test implants toward the prostheses was observed compared with the control implants. This led to a significant decrease in prosthesis misfit for the test implants compared with the control implants. Conclusions: This study indicates that prosthesis misfit does not per se lead to biologic failure of immediately loaded or of already osseointegrated implants. In addition, immediately loaded implants seem to topographically adapt to the prosthesis, thereby minimizing the existing misfit.
Notes: Katholieke Univ Leuven, BIOMAT Res Grp, Dept Prosthet Dent, UZ St Raphael, B-3000 Louvain, Belgium. Ziekenhuis Oost Limburg, Dept Oral & Maxillofacial Surg, Genk, Belgium. Limburgs Univ Ctr, Dept Basic Med Sci, Diepenbeek, Belgium. Hiroshima Univ, Grad Sch Biomed Sci, Div Cervicognathostomatol, Dept Adv Prosthodont, Hiroshima, Japan.Duyck, J, Katholieke Univ Leuven, BIOMAT Res Grp, Dept Prosthet Dent, UZ St Raphael, Kapucijnenvoer 7, B-3000 Louvain, Belgium.Joke.Duyck@uz.kuleuven.ac.be
Keywords: animal; bone histology; immediate implant loading; prosthesis misfit
Document URI: http://hdl.handle.net/1942/2155
ISSN: 1523-0899
e-ISSN: 1708-8208
DOI: 10.1111/j.1708-8208.2005.tb00059.x
ISI #: 000237226200005
Category: A1
Type: Journal Contribution
Validations: ecoom 2007
Appears in Collections:Research publications

Show full item record

SCOPUSTM   
Citations

31
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

37
checked on Apr 22, 2024

Page view(s)

80
checked on May 30, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.