Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/21811
Title: Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius
Authors: de Jong, Joost J. A.
Arts, Jacobus J.C.
Meyer, Ursina
Willems, Paul C.
GEUSENS, Piet 
VAN DEN BERGH, Joop 
van Rietbergen, Bert
Issue Date: 2016
Publisher: JOURNAL BONE JOINT SURGERY INC
Source: JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 98A (5), p. 356-362
Abstract: Background: High-resolution peripheral quantitative computed tomography (HR-pQCT) is a promising tool to assess the fracture-healing process at the microscale in vivo. Since casts are often used during fracture treatment, they might affect the assessment of bone density, microarchitectural, and biomechanical parameters and the short-term reproducibility of those parameters, e.g., as a result of beam-hardening. The aim of this study was to assess the effect of a plaster-of-Paris and/or fiberglass cast on bone parameters and on the short-term reproducibility of the HR-pQCT measurements of those parameters. Methods: The effects of a cast on HR-pQCT-derived bone parameters were evaluated by comparing HR-pQCT scans of fifteen human cadaveric distal radial specimens from one male and fourteen female donors (median age, eighty-four years [ range, sixty-two to ninety years] at the time of death) in three conditions: with a plaster-of-Paris cast, with a fiberglass cast, or without a cast. Short-term reproducibility was assessed using duplicate scans of the distal end of the radius in sixteen healthy volunteers without a fracture (nine men and seven women with a median age of twenty-six years; range, twenty-two to thirty-nine years) while wearing and not wearing a fiberglass cast. Results: Compared with measurements made with no cast, the plaster-of-Paris cast introduced a systematic error in the bone parameters ranging from -2.6% in trabecular separation to -9.8% in cortical thickness. Bone parameters were affected only marginally by fiberglass, with errors between -0.6% and -1.6% in trabecular separation and cortical thickness, respectively. Short-term reproducibility with a fiberglass cast was similar to that with no cast: approximately 1% for bone density parameters, 4% to 5% for microarchitectural parameters, and 3% to 4% for biomechanical parameters. Conclusions: A plaster-of-Paris cast has a considerable effect on HR-pQCT measurements. A fiberglass cast only marginally affects the bone parameters, and the short-term reproducibility of HR-pQCT measurements in patients with a fiberglass cast is comparable with that in patients without a cast. In studies on fracture-healing using HR-pQCT, a fiberglass cast is desirable if immobilization is indicated. The use of a plaster-of-Paris cast should be avoided if possible; however, if not avoidable, corrections after the scan are desirable to adjust for the error introduced in the bone parameters.
Notes: [de Jong, Joost J. A.; Arts, Jacobus J.; Meyer, Ursina; Willems, Paul C.; Geusens, Piet P.; van den Bergh, Joop P. W.; van Rietbergen, Bert] Eindhoven Univ Technol, Fac Biomed Engn, POB 513, NL-5600 MB Eindhoven, Netherlands. [de Jong, Joost J. A.; Meyer, Ursina; van den Bergh, Joop P. W.] Maastricht Univ, Res Sch NUTRIM, NL-6200 MD Maastricht, Netherlands. [Arts, Jacobus J.; Willems, Paul C.; Geusens, Piet P.] Maastricht Univ, CAPHRI, NL-6200 MD Maastricht, Netherlands. [de Jong, Joost J. A.; Meyer, Ursina; Geusens, Piet P.; van den Bergh, Joop P. W.] Maastricht Univ, Med Ctr, Dept Rheumatol, NL-6200 MD Maastricht, Netherlands. [Arts, Jacobus J.; Willems, Paul C.] Maastricht Univ, Med Ctr, Dept Orthopaed Surg, NL-6200 MD Maastricht, Netherlands. [Meyer, Ursina] Maastricht Univ, Med Ctr, Dept Human Movement Sci, NL-6200 MD Maastricht, Netherlands. [van den Bergh, Joop P. W.] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium. [van den Bergh, Joop P. W.] VieCuri Med Ctr, Dept Internal Med, Venlo, Netherlands.
Document URI: http://hdl.handle.net/1942/21811
ISSN: 0021-9355
e-ISSN: 1535-1386
DOI: 10.2106/JBJS.O.00127
ISI #: 000371147700007
Rights: COPYRIGHT © 2016 BY THE JOURNAL OF BONE AND JOINT SURGERY, INCORPORATED
Category: A1
Type: Journal Contribution
Validations: ecoom 2017
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
10.2106@JBJS.O.00127.pdf
  Restricted Access
Published version802.98 kBAdobe PDFView/Open    Request a copy
Show full item record

SCOPUSTM   
Citations

7
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

13
checked on Apr 22, 2024

Page view(s)

60
checked on Sep 6, 2022

Download(s)

40
checked on Sep 6, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.