Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/21838
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEERSELS, Kasper-
dc.contributor.authorVAN GRINSVEN, Bart-
dc.contributor.authorVANDENRYT, Thijs-
dc.contributor.authorJIMENEZ MONROY, Kathia-
dc.contributor.authorPEETERS, Marloes-
dc.contributor.authorSOMERS, Veerle-
dc.contributor.authorCLEIJ, Thomas-
dc.contributor.authorTHOELEN, Ronald-
dc.contributor.authorDE CEUNINCK, Ward-
dc.contributor.authorPuettmann, C.-
dc.contributor.authorBOS, Gerard-
dc.contributor.authorStein, C.-
dc.contributor.authorBarth, Stefan-
dc.contributor.authorGERMERAAD, Wilfred-
dc.contributor.authorDILIEN, Hanne-
dc.contributor.authorWAGNER, Patrick-
dc.date.accessioned2016-07-20T09:17:52Z-
dc.date.available2016-07-20T09:17:52Z-
dc.date.issued2015-
dc.identifier.citationPHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 212 (6), p. 1320-1326-
dc.identifier.issn1862-6300-
dc.identifier.urihttp://hdl.handle.net/1942/21838-
dc.description.abstractIn this article, we increased the sensitivity of the heat-transfer method (HTM) for the detection of breast cancer cells (ZR-75-1 cells, see figure) in phosphate buffered saline (PBS). The effect of small technological changes on the limit of detection (LoD) of the methodology was examined. To this extent, polished aluminum substrates with a mirror finish were used, replacing the unpolished chips used in previous studies. These chips were coated with a polyurethane layer and imprinted for the target cell type, creating a so-called surface imprinted-polymer (SIP). Binding of target cells to the SIP resulted in an increase of the thermal resistance at the solid-liquid interface under study. Background thermal resistance measurements were performed with polished and unpolished aluminum substrates. In addition, the effect of using silver paste as thermal coupling between the aluminum chip and the copper heat provider was analyzed. The results of these experiments reveal that optimal thermal contact is achieved when directly coupling the copper heat provider to the polished side of the aluminum substrate as evidenced by a decrease in the baseline thermal resistance. In addition, noise levels on the heat-transfer resistance (R-th) signal decreased by a factor in the optimal configuration. Dose-response curves were obtained using the optimized methodology and were compared with results obtained with the original substrates. These quantitative experiments demonstrated an improvement of the LoD by approximately thirty percent. ZR-75-1 cells applied onto a home-made rubber stamp.-
dc.description.sponsorshipInterreg IV-A project MicroBioMed (European Funds for Regional Development); Life Science Initiative of the Province of Limburg; Special Research Funds BOF of Hasselt University; Research Foundation Flanders FWO [G.0B.6213.N]; Flemish Government "Methusalem Nano"-
dc.language.isoen-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.rights© 2015 WILEY VCH Verlag GmbH & Co. KGaA, Weinheim-
dc.subject.otheraluminum; biosensors; cancer cells; heat-transfer method (HTM); polishing-
dc.subject.otheraluminum; biosensors; cancer cells; heat-transfer method (HTM); polishing-
dc.titleImproving the sensitivity of the heat-transfer method (HTM) for cancer cell detection with optimized sensor chips-
dc.typeJournal Contribution-
dc.identifier.epage1326-
dc.identifier.issue6-
dc.identifier.spage1320-
dc.identifier.volume212-
local.format.pages7-
local.bibliographicCitation.jcatA1-
dc.description.notes[Eersels, K.; van Grinsven, B.; Vandenryt, T.; Jimenez-Monroy, K. L.; Peeters, M.; Thoelen, R.; De Ceuninck, W.; Wagner, P.] Hasselt Univ, Inst Mat Res, B-3590 Diepenbeek, Belgium. [van Grinsven, B.; Dilien, H.; Cleij, T. J.] Maastricht Univ, Maastricht Sci Programme, NL-6200 MD Maastricht, Netherlands. [Somers, V.] Hasselt Univ, Biomed Res Inst, B-3590 Diepenbeek, Belgium. [Puettmann, C.; Stein, C.; Barth, S.] Uniklin RWTH Aachen Univ, Inst Appl Med Engn, Dept Expt Med & Immunotherapy, D-52074 Aachen, Germany. [Bos, G. M. J.; Germeraad, W. T. V.] Maastricht Univ, Med Ctr, Dept Internal Med, Div Haematol, NL-6200 MD Maastricht, Netherlands. [Thoelen, R.; De Ceuninck, W.; Wagner, P.] IMEC VZW, IMOMEC Div, B-3590 Diepenbeek, Belgium.-
local.publisher.placeWEINHEIM-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.doi10.1002/pssa.201431709-
dc.identifier.isi000356706500021-
item.fulltextWith Fulltext-
item.contributorEERSELS, Kasper-
item.contributorVAN GRINSVEN, Bart-
item.contributorVANDENRYT, Thijs-
item.contributorJIMENEZ MONROY, Kathia-
item.contributorPEETERS, Marloes-
item.contributorSOMERS, Veerle-
item.contributorCLEIJ, Thomas-
item.contributorTHOELEN, Ronald-
item.contributorDE CEUNINCK, Ward-
item.contributorPuettmann, C.-
item.contributorBOS, Gerard-
item.contributorStein, C.-
item.contributorBarth, Stefan-
item.contributorGERMERAAD, Wilfred-
item.contributorDILIEN, Hanne-
item.contributorWAGNER, Patrick-
item.accessRightsRestricted Access-
item.validationecoom 2016-
item.fullcitationEERSELS, Kasper; VAN GRINSVEN, Bart; VANDENRYT, Thijs; JIMENEZ MONROY, Kathia; PEETERS, Marloes; SOMERS, Veerle; CLEIJ, Thomas; THOELEN, Ronald; DE CEUNINCK, Ward; Puettmann, C.; BOS, Gerard; Stein, C.; Barth, Stefan; GERMERAAD, Wilfred; DILIEN, Hanne & WAGNER, Patrick (2015) Improving the sensitivity of the heat-transfer method (HTM) for cancer cell detection with optimized sensor chips. In: PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 212 (6), p. 1320-1326.-
crisitem.journal.issn1862-6300-
crisitem.journal.eissn1862-6319-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Eersels_et_al-2015-physica_status_solidi_(a).pdf
  Restricted Access
Published version400.35 kBAdobe PDFView/Open    Request a copy
Show simple item record

SCOPUSTM   
Citations

10
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

12
checked on Apr 22, 2024

Page view(s)

68
checked on Aug 4, 2022

Download(s)

46
checked on Aug 4, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.