Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/2361
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVan Erck, E-
dc.contributor.authorVotion, D-
dc.contributor.authorKirschvink, N-
dc.contributor.authorGenicot, B-
dc.contributor.authorArt, T.-
dc.contributor.authorLINDSEY, James-
dc.contributor.authorLekeux, P-
dc.date.accessioned2007-11-13T22:01:13Z-
dc.date.available2007-11-13T22:01:13Z-
dc.date.issued2004-
dc.identifier.citationVETERINARY JOURNAL, 168(3). p. 259-269-
dc.identifier.issn1090-0233-
dc.identifier.urihttp://hdl.handle.net/1942/2361-
dc.description.abstractThe objective of this paper was to determine if changes in ventilation patterns could influence the outcome of respiratory function measurements performed with our impulse oscillometry system (IOS) in horses. In a first study, IOS tests were performed in vitro on six isolated equine lungs. Lung inflation levels were controlled by modifying depressurisation inside an artificial thorax and different ventilation patterns were imposed. In a second in vivo study, transient variations in breathing pattern were evaluated both with the IOS and a current reference technique (CRT) in five healthy mature horses after an intravenous (i.v.) injection of lobefine hydrochloride. In both studies, respiratory rate (RR, range: 7-42 breaths/min.) and tidal volume (V-T, range: 0.4-25 L) had minor or no influence on IOS parameters. The influence of lung inflation, most marked for resistance at 5 Hz (R-5 (Hz)), was limited for the considered physiological range. In vivo, statistical models indicated that maximal changes in pleural pressure (MaxDeltaPpl) and peak flows were the main determinants of the variability of the resistance (R-rs) and the reactance (X-rs) of the respiratory system. The fourfold increase in baseline MaxDeltaPpl and peak flows obtained during hyperpnoea caused a significant increase in R-rs at 5 and 10 Hz and a decrease in X,, at all frequencies. We conclude that IOS parameters are not influenced by tachypnoea, but will reflect alterations in respiratory mechanics caused by hyperpnoeic breathing. (C) 2003 Elsevier Ltd. All rights reserved.-
dc.language.isoen-
dc.publisherBAILLIERE TINDALL-
dc.subject.otherpulmonary function test; forced oscillations; impulse oscillometry; horse; breathing pattern-
dc.titleInfluence of breathing pattern and lung inflation on impulse oscillometry measurements in horses-
dc.typeJournal Contribution-
dc.identifier.epage269-
dc.identifier.issue3-
dc.identifier.spage259-
dc.identifier.volume168-
local.format.pages11-
local.bibliographicCitation.jcatA1-
dc.description.notesUniv Liege, Lab Funct Invest, Dept Physiol, Fac Med Vet, B-4000 Liege, Belgium. Limburgs Univ Centrum, Dept Biostat, Diepenbeek, Belgium.Van Erck, E, Univ Liege, Lab Funct Invest, Dept Physiol, Fac Med Vet, Bat B42, B-4000 Liege, Belgium.emmanuelle.vanerck@skynet.be-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.doi10.1016/j.tvjl.2003.09.010-
dc.identifier.isi000225110200010-
item.contributorVan Erck, E-
item.contributorVotion, D-
item.contributorKirschvink, N-
item.contributorGenicot, B-
item.contributorArt, T.-
item.contributorLINDSEY, James-
item.contributorLekeux, P-
item.fulltextNo Fulltext-
item.validationecoom 2005-
item.fullcitationVan Erck, E; Votion, D; Kirschvink, N; Genicot, B; Art, T.; LINDSEY, James & Lekeux, P (2004) Influence of breathing pattern and lung inflation on impulse oscillometry measurements in horses. In: VETERINARY JOURNAL, 168(3). p. 259-269.-
item.accessRightsClosed Access-
crisitem.journal.issn1090-0233-
crisitem.journal.eissn1532-2971-
Appears in Collections:Research publications
Show simple item record

SCOPUSTM   
Citations

6
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

9
checked on Apr 30, 2024

Page view(s)

80
checked on Jul 31, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.