Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/24117
Title: Short-term Effects of Supplemental Oxygen on 6-Min Walk Test Outcomes in Patients With COPD A Randomized, Placebo-Controlled, Single-blind, Crossover Trial
Authors: Jarosch, Inga
Gloeckl, Rainer
Damm, Eva
Schwedhelm, Anna-Lena
Buhrow, David
Jerrentrup, Andreas
SPRUIT, Martijn A. 
Kenn, Klaus
Issue Date: 2017
Publisher: AMER COLL CHEST PHYSICIANS
Source: CHEST, 151(4), p. 795-803
Abstract: BACKGROUND: The acute effect of supplemental oxygen during exercise has been shown to differ largely among patients with COPD. It is unknown what factors influence oxygen response. METHODS: In a randomized, single-blind fashion, 124 patients with COPD underwent one 6-min walk test on supplemental oxygen (6MWT(O2)) and one 6-min walk test on room air after a practice 6-min walk test. Both gases were delivered via standard nasal prongs (2 L/min). For analyses, patients were stratified on the basis of PaO2 values and compared: (1) 34 patients with resting hypoxemia (HYX); (2) 43 patients with exercise-induced hypoxemia (EIH); and (3) 31 patients with normoxemia (NOX). RESULTS: Oxygen supplementation resulted in an increase in the 6-min walk distance in the total cohort (27 +/- 42 meters; P < .001) and in the subgroups of HYX (37 +/- 40 meters; P < .001) and EIH (28 +/- 44 meters; P < .001) but not in the NOX subgroup (15 +/- 43 meters; P = .065). Forty-two percent of patients with HYX and 47% of patients with EIH improved their 6-min walk distance to a clinically relevant extent (>= 30 meters) by using oxygen. These oxygen responders were characterized by significantly lower 6-min walk distance using room air compared with patients without a relevant response (306 +/- 106 meters vs 358 +/- 113 meters; P < .05). Although oxygen saturation was significantly higher during 6MWT(O2) compared with the 6-min walk test on roomair in all 3 subgroups, it dropped to < 88% during 6MWT(O2) in 73.5% of patients with HYX. CONCLUSIONS: In contrast to patients with NOX, patients with HYX and EIH generally benefit from supplemental oxygen by increasing exercise capacity. However, less than one-half of patients reached the threshold of clinically relevant improvements. These oxygen responders were characterized by significantly lower exercise capacity levels.
Notes: [Jarosch, Inga; Gloeckl, Rainer; Kenn, Klaus] Schoen Klin Berchtesgadener Land, Dept Resp Med & Pulm Rehabil, Malterhoeh 1, D-83471 Schoenau Koenigssee, Germany. [Gloeckl, Rainer] Tech Univ Munich, Klinikum Rechts Isar, Dept Prevent Rehabil & Sports Med, Munich, Germany. [Damm, Eva; Schwedhelm, Anna-Lena; Buhrow, David; Jerrentrup, Andreas] Univ Marburg, Dept Pneumol & Crit Care Med, Marburg, Germany. [Spruit, Martijn A.] Ctr Expertise Chron Organ Failure, CIRO, Dept Res & Educ, Horn, Netherlands. [Spruit, Martijn A.] Hasselt Univ, Fac Med & Life Sci, REVAL Rehabil Res Ctr, BIOMED Biomed Res Inst, Diepenbeek, Belgium. [Spruit, Martijn A.] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, Dept Resp Med, Maastricht, Netherlands. [Kenn, Klaus] Univ Marburg, Dept Pulm Rehabil, Marburg, Germany.
Keywords: 6-min walking distance; COPD; exercise-induced hypoxemia; exercise testing; supplemental oxygen;6-min walking distance; COPD; exercise-induced hypoxemia; exercise testing; supplemental oxygen
Document URI: http://hdl.handle.net/1942/24117
ISSN: 0012-3692
e-ISSN: 1931-3543
DOI: 10.1016/j.chest.2016.11.044
ISI #: 000398731500021
Category: A1
Type: Journal Contribution
Validations: ecoom 2018
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
manuscript.pdfPeer-reviewed author version484.08 kBAdobe PDFView/Open
PIIS0012369216625722.pdf
  Restricted Access
Published version411.28 kBAdobe PDFView/Open    Request a copy
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.