Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/24339
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | SMEETS, Kristof | - |
dc.contributor.author | Slane, Josh | - |
dc.contributor.author | Scheys, Lennart | - |
dc.contributor.author | Forsyth, Ramses | - |
dc.contributor.author | Claes, Steven | - |
dc.contributor.author | BELLEMANS, Johan | - |
dc.date.accessioned | 2017-08-31T10:46:24Z | - |
dc.date.available | 2017-08-31T10:46:24Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 33(5), p. 1028-1035.e1 (Art N° 1028) | - |
dc.identifier.issn | 0749-8063 | - |
dc.identifier.uri | http://hdl.handle.net/1942/24339 | - |
dc.description.abstract | Purpose: To characterize the tensile and histologic properties of the anterolateral ligament (ALL), inferior glenohumeral ligament (IGHL), and knee capsule. Methods: Standardized samples of the ALL (n = 19), anterolateral knee capsule (n = 15), and IGHL (n = 13) were isolated from fresh-frozen human cadavers for uniaxial tensile testing to failure. An additional 6 samples of the ALL, capsule, and IGHL were procured for histologic analysis and determination of elastin content. Results: All investigated mechanical properties were significantly greater for both the ALL and IGHL when compared with capsular tissue. In contrast, no significant differences between the ALL and IGHL were found for any property. The elastic modulus of ALL and IGHL samples was 174 +/- 92 MPa and 139 +/- 60 MPa, respectively, compared with 62 +/- 30 MPa for the capsule (P +/- .001). Ultimate stress was significantly lower (P < .001) for the capsule, at 13.4 +/- 7.7 MPa, relative to the ALL and IGHL, at 46.4 +/- 20.1 MPa and 38.7 +/- 16.3 MPa, respectively. The ultimate strain at failure was 37.8% +/- 7.9% for the ALL and 39.5% +/- 9.4% for the IGHL; this was significantly greater (P = .041 and P = .02, respectively) for both relative to the capsule, at 32.6% +/- 8.4%. The strain energy density was 7.8 +/- 3.1 MPa for the ALL, 2.1 +/- 1.3 MPa for the capsule, and 7.1 +/- 3.1 MPa for the IGHL (P < .001). The ALL and IGHL consisted of collagen bundles aligned in a parallel manner, containing elastin bundles, which was in contrast to the random collagen architecture noted in capsule samples. Conclusions: The ALL has similar tensile and histologic properties to the IGHL. The tensile properties of the ALL are significantly greater than those observed in the knee capsule. | - |
dc.description.sponsorship | The authors report the following potential conflicts of interest or sources of funding: Study partially funded by Belgische Vereniging voor Orthopedie en Traumatologie. | - |
dc.language.iso | en | - |
dc.publisher | W B SAUNDERS CO-ELSEVIER INC | - |
dc.rights | 2017 by the Arthroscopy Association of North America | - |
dc.title | The Anterolateral Ligament Has Similar Biomechanical and Histologic Properties to the Inferior Glenohumeral Ligament | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 1035.e1 | - |
dc.identifier.issue | 5 | - |
dc.identifier.spage | 1028 | - |
dc.identifier.volume | 33 | - |
local.format.pages | 9 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | [Smeets, Kristof] Hasselt Univ, Doctoral Sch Med & Life Sci, Hasselt, Belgium. [Smeets, Kristof; Bellemans, Johan] Ziekenhuis Oost Limburg, Dept Orthoped Surg, Genk, Belgium. [Slane, Josh; Scheys, Lennart] Univ Hosp Leuven, Inst Orthopaed Res & Training, Campus Pellenberg, Pellenberg, Belgium. [Forsyth, Ramses] Univ Hosp Brussels, Dept Pathol, Brussels, Belgium. [Claes, Steven] AZ Herentals Hosp, Dept Orthoped Surg, Herentals, Belgium. | - |
local.publisher.place | 1600 JOHN F KENNEDY BOULEVARD, STE 1800, PHILADELPHIA, PA 19103-2899 | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | 1028 | - |
dc.identifier.doi | 10.1016/j.arthro.2017.01.038 | - |
dc.identifier.isi | 000402470800029 | - |
dc.identifier.eissn | 1526-3231 | - |
local.uhasselt.international | no | - |
item.fullcitation | SMEETS, Kristof; Slane, Josh; Scheys, Lennart; Forsyth, Ramses; Claes, Steven & BELLEMANS, Johan (2017) The Anterolateral Ligament Has Similar Biomechanical and Histologic Properties to the Inferior Glenohumeral Ligament. In: ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 33(5), p. 1028-1035.e1 (Art N° 1028). | - |
item.validation | ecoom 2018 | - |
item.accessRights | Open Access | - |
item.fulltext | With Fulltext | - |
item.contributor | SMEETS, Kristof | - |
item.contributor | Slane, Josh | - |
item.contributor | Scheys, Lennart | - |
item.contributor | Forsyth, Ramses | - |
item.contributor | Claes, Steven | - |
item.contributor | BELLEMANS, Johan | - |
crisitem.journal.issn | 0749-8063 | - |
crisitem.journal.eissn | 1526-3231 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
smeets2017.pdf Restricted Access | In press | 1.51 MB | Adobe PDF | View/Open Request a copy |
The anterlateral.pdf | Peer-reviewed author version | 452.78 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
8
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
15
checked on Jul 18, 2024
Page view(s)
70
checked on Jul 20, 2022
Download(s)
40
checked on Jul 20, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.