Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/26448
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKefer, Joelle-
dc.contributor.authorAminian, Adel-
dc.contributor.authorVermeersch, Paul-
dc.contributor.authorde Potter, Tom-
dc.contributor.authorStammen, Francis-
dc.contributor.authorBENIT, Edouard-
dc.contributor.authorBudts, Werner-
dc.contributor.authorMissault, Luc-
dc.contributor.authorDrieghe, Benny-
dc.contributor.authorBuysschaert, Ian-
dc.contributor.authorCornelis, Kristoff-
dc.contributor.authorHerzet, Jean-Manuel-
dc.contributor.authorGuedes, Antoine-
dc.contributor.authorDebbas, Nadia-
dc.contributor.authorRivero, Maximo-
dc.contributor.authorLempereur, Mathieu-
dc.contributor.authorLochy, Stijn-
dc.contributor.authorCasado-Arroyo, Ruben-
dc.contributor.authorLaruelle, Christophe-
dc.contributor.authorDebruyne, Philippe-
dc.contributor.authorLedent, Thierry-
dc.date.accessioned2018-07-30T08:50:42Z-
dc.date.available2018-07-30T08:50:42Z-
dc.date.issued2018-
dc.identifier.citationEUROINTERVENTION, 13(13), p. 1603-1611-
dc.identifier.issn1774-024X-
dc.identifier.urihttp://hdl.handle.net/1942/26448-
dc.description.abstractAims: This study aimed to assess the safety and efficacy at midterm follow-up of left atrial appendage occlusion (LAAO) using different devices, in real life in Belgium. Methods and results: Between June 2009 and November 2016, 457 consecutive patients (63% male, 75 +/- 12 yrs, CHA(2)DS(2)-VASc 4 +/- 0.6, HAS-BLED 3.5 +/- 0.7) undergoing LAAO were included. Technical success was 97.1%. There were 19 periprocedural major adverse events (4.1%) including three deaths (0.6%), nine tamponades (1.9%), four major bleedings (0.8%) and two device embolisations (0.4%). Among patients successfully implanted having a complete follow-up (672 patient-years, median follow-up 370 days), the actual annual stroke rate was 1.2%, lower than the expected stroke risk of 4% (70% reduction). The observed bleeding rate was 2%, while the calculated risk was 3.7% (46% reduction). Kaplan-Meier analysis showed a similar overall survival (93 +/- 2% and 87 +/- 3% versus 91 +/- 3% and 87 +/- 4%; p=0.35) and event-free survival (92 +/- 2% and 84 +/- 3% versus 88 +/- 3% and 80 +/- 5%; p=0.17) at one and two years, for the ACP/Amulet versus the WATCHMAN groups of patients, respectively. Conclusions: The data from the Belgian left atrial appendage occlusion registry suggest that the procedure is effective and relatively safe in a real-world setting, using either the WATCHMAN or the ACP/Amulet device.-
dc.language.isoen-
dc.subject.otherstroke; bleeding; atrial fibrillation; specific device closure/technique-
dc.titleTranscatheter left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: results from the Belgian registry-
dc.typeJournal Contribution-
dc.identifier.epage1611-
dc.identifier.issue13-
dc.identifier.spage1603-
dc.identifier.volume13-
local.bibliographicCitation.jcatA1-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.classdsPublValOverrule/internal_author_not_expected-
local.classIncludeIn-ExcludeFrom-List/ExcludeFromFRIS-
dc.identifier.doi10.4244/EIJ-D-17-00076-
dc.identifier.isi000424327300019-
item.fullcitationKefer, Joelle; Aminian, Adel; Vermeersch, Paul; de Potter, Tom; Stammen, Francis; BENIT, Edouard; Budts, Werner; Missault, Luc; Drieghe, Benny; Buysschaert, Ian; Cornelis, Kristoff; Herzet, Jean-Manuel; Guedes, Antoine; Debbas, Nadia; Rivero, Maximo; Lempereur, Mathieu; Lochy, Stijn; Casado-Arroyo, Ruben; Laruelle, Christophe; Debruyne, Philippe & Ledent, Thierry (2018) Transcatheter left atrial appendage occlusion for stroke prevention in patients with atrial fibrillation: results from the Belgian registry. In: EUROINTERVENTION, 13(13), p. 1603-1611.-
item.contributorKefer, Joelle-
item.contributorAminian, Adel-
item.contributorVermeersch, Paul-
item.contributorde Potter, Tom-
item.contributorStammen, Francis-
item.contributorBENIT, Edouard-
item.contributorBudts, Werner-
item.contributorMissault, Luc-
item.contributorDrieghe, Benny-
item.contributorBuysschaert, Ian-
item.contributorCornelis, Kristoff-
item.contributorHerzet, Jean-Manuel-
item.contributorGuedes, Antoine-
item.contributorDebbas, Nadia-
item.contributorRivero, Maximo-
item.contributorLempereur, Mathieu-
item.contributorLochy, Stijn-
item.contributorCasado-Arroyo, Ruben-
item.contributorLaruelle, Christophe-
item.contributorDebruyne, Philippe-
item.contributorLedent, Thierry-
item.fulltextNo Fulltext-
item.accessRightsClosed Access-
crisitem.journal.issn1774-024X-
crisitem.journal.eissn1969-6213-
Appears in Collections:Research publications
Show simple item record

SCOPUSTM   
Citations

5
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

13
checked on May 8, 2024

Page view(s)

80
checked on Jun 28, 2023

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.