Title: Temperature controlled interval contact design for ultrasound assisted liquid-liquid extraction
Authors: John, Jinu Joseph
Kuhn, Simon
BRAEKEN, Leen 
Van Gerven, Tom
Issue Date: 2017
Source: CHEMICAL ENGINEERING RESEARCH & DESIGN, 125, p. 146-155
Abstract: This work aims at constructing a design which integrates a direct (solid) contact method with temperature control for chemical process applications. To realise this integration a two-step approach is proposed. Firstly, temperature control is achieved by suspending the tubing in a temperature controlled and sonicated liquid medium (indirect contact). Secondly, direct contact elements are introduced at regular intervals along the tubing. Therefore, this design is termed the hybrid contact reactor, as it incorporates both direct and indirect approaches of ultrasound transfer. Furthermore, two possible configurations, open and closed interval connection to the tubing, were assessed. Both hybrid reactors performed better than the indirect contact reactor (20-27% increase in yield) for residence times of less than 45 s and similar for residence times above. Even though the performance of the two hybrid designs was similar the closed interval resulted in more reproducible and distinct yields. This configuration was then scaled up 10 times in internal volume using a 2 mm ID tube. This design showed a relative performance similar to the interval contact design which gave the highest yields thus far for the same operating conditions. (C) 2017 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
Keywords: liquid-liquid extraction; ultrasound; mass & heat transfer; reactor design; flow reactors
Document URI: http://hdl.handle.net/1942/26452
ISSN: 0263-8762
e-ISSN: 1744-3563
DOI: 10.1016/j.cherd.2017.06.025
ISI #: 000411846800014
Rights: ©2017 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
Braeken2017.pdf
  Restricted Access
Published version4.29 MBAdobe PDFView/Open    Request a copy
Temperaturecontrolledintervalcontactdesignforultrasoundassistedliquid-liquidextraction_preprint.pdfPeer-reviewed author version2.55 MBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

12
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

21
checked on Oct 14, 2024

Page view(s)

68
checked on Sep 7, 2022

Download(s)

190
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.