Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/26508
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBAETEN, Brecht-
dc.contributor.authorConfrey, Thomas-
dc.contributor.authorPecceu, Sebastien-
dc.contributor.authorROGIERS, Frederik-
dc.contributor.authorHelsen, Lieve-
dc.date.accessioned2018-07-31T10:15:41Z-
dc.date.available2018-07-31T10:15:41Z-
dc.date.issued2016-
dc.identifier.citationAPPLIED ENERGY, 172, p. 217-229-
dc.identifier.issn0306-2619-
dc.identifier.urihttp://hdl.handle.net/1942/26508-
dc.description.abstractWhen evaluating the energy demand of buildings using stratified hot water storage tanks in an active demand response context, an accurate but low order storage tank model is required. Accurate modelling of buoyancy effects and mixing inside the storage tank as a result of direct inflows is key to obtain valid results. The use of one-dimensional storage tank models is common practice in building simulations, but as buoyancy and mixing are three-dimensional phenomena they cannot be incorporated directly in such a model and special formulations must be used. This paper presents a novel method for incorporating buoyancy and mixing in one-dimensional stratified storage tank models. The model parameters are derived from a series of computational fluid dynamics simulations and correlated with the appropriate non-dimensional parameters. The model is validated against an independent set of charging and discharging experiments. The model is found to represent buoyancy and mixing in the storage tank in a realistic way and to correspond well to experimental results. To allow researchers to assess the uncertainty on performance indicators in building energy simulations, an effective storage capacity ratio is defined and its variation within the model parameter uncertainty range is calculated and compared to other models. The results show a discrepancy between models commonly used in the literature and the presented validated model. When the influence of storage capacity on parameters of interest is known, the effective storage capacity ratio can also be used to estimate the uncertainty on these parameters caused by the storage tank model. (C) 2016 Elsevier Ltd. All rights reserved.-
dc.language.isoen-
dc.rights(C) 2016 Elsevier Ltd. All rights reserved-
dc.subject.otherstratified hot water storage; one-dimensional model; buoyancy; inflow mixing; experimental validation-
dc.titleA validated model for mixing and buoyancy in stratified hot water storage tanks for use in building energy simulations-
dc.typeJournal Contribution-
dc.identifier.epage229-
dc.identifier.spage217-
dc.identifier.volume172-
local.bibliographicCitation.jcatA1-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.classdsPublValOverrule/internal_author_not_expected-
local.classIncludeIn-ExcludeFrom-List/ExcludeFromFRIS-
dc.identifier.doi10.1016/j.apenergy.2016.03.118-
dc.identifier.isi000376790400019-
item.fullcitationBAETEN, Brecht; Confrey, Thomas; Pecceu, Sebastien; ROGIERS, Frederik & Helsen, Lieve (2016) A validated model for mixing and buoyancy in stratified hot water storage tanks for use in building energy simulations. In: APPLIED ENERGY, 172, p. 217-229.-
item.contributorBAETEN, Brecht-
item.contributorConfrey, Thomas-
item.contributorPecceu, Sebastien-
item.contributorROGIERS, Frederik-
item.contributorHelsen, Lieve-
item.fulltextWith Fulltext-
item.accessRightsRestricted Access-
crisitem.journal.issn0306-2619-
crisitem.journal.eissn1872-9118-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Validated.pdf
  Restricted Access
Published version2.25 MBAdobe PDFView/Open    Request a copy
Show simple item record

SCOPUSTM   
Citations

20
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

42
checked on Jul 21, 2024

Page view(s)

76
checked on Sep 7, 2022

Download(s)

68
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.