Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/26537
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVan Keer, Karel-
dc.contributor.authorVan Keer, Jan-
dc.contributor.authorBreda, Joao Barbosa-
dc.contributor.authorNASSIRI, Vahid-
dc.contributor.authorDE DEYNE, Cathy-
dc.contributor.authorGENBRUGGE, Cornelia-
dc.contributor.authorPinto, Luis Abegao-
dc.contributor.authorStalmans, Ingeborg-
dc.contributor.authorVandewalle, Evelien-
dc.date.accessioned2018-08-02T10:11:33Z-
dc.date.available2018-08-02T10:11:33Z-
dc.date.issued2018-
dc.identifier.citationPLOS ONE, 13(1) (Art N° e0190612)-
dc.identifier.issn1932-6203-
dc.identifier.urihttp://hdl.handle.net/1942/26537-
dc.description.abstractBackground To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO(2-retinal)) and venous (SvO(2-retinal)) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial: venous ratio as 0.3 x SaO(2-retinal) + 0.7 x SvO(2-retinal). The individual relative weight of SaO(2-retinal) and SvO(2-retinal) to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 +/- 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO(2-retinal) and SvO(2-retinal) (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO(2-retinal) and SvO(2-retinal) to obtain SO2-transcranial were 0.31 +/- 0.11 and 0.69 +/- 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial: venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation.-
dc.language.isoen-
dc.publisherPUBLIC LIBRARY SCIENCE-
dc.rights© 2018 Van Keer et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.-
dc.titleNon-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry-
dc.typeJournal Contribution-
dc.identifier.issue1-
dc.identifier.volume13-
local.format.pages14-
local.bibliographicCitation.jcatA1-
dc.description.notes[Van Keer, Karel; Breda, Joao Barbosa; Stalmans, Ingeborg; Vandewalle, Evelien] Univ Hosp Leuven, Dept Ophthalmol, Leuven, Belgium. [Van Keer, Jan] Univ Hosp Leuven, Dept Cardiol, Leuven, Belgium. [Nassiri, Vahid] Katholieke Univ Leuven, I BioStat, Leuven, Belgium. [De Deyne, Cathy; Genbrugge, Cornelia] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium. [De Deyne, Cathy; Genbrugge, Cornelia] Ziekenhuis Oost Limburg, Dept Anesthesiol Intens Care Emergency Med & Pain, Genk, Belgium. [Pinto, Luis Abegao] Ctr Hosp Lisboa Norte, Dept Ophthalmol, Lisbon, Portugal. [Stalmans, Ingeborg] Katholieke Univ Leuven, Lab Ophthalmol, Dept Ophthalmol Neurosci, Leuven, Belgium.-
local.publisher.placeSAN FRANCISCO-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre0190612-
local.classdsPublValOverrule/author_version_not_expected-
dc.identifier.doi10.1371/journal.pone.0190612-
dc.identifier.isi000419403800080-
item.fullcitationVan Keer, Karel; Van Keer, Jan; Breda, Joao Barbosa; NASSIRI, Vahid; DE DEYNE, Cathy; GENBRUGGE, Cornelia; Pinto, Luis Abegao; Stalmans, Ingeborg & Vandewalle, Evelien (2018) Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry. In: PLOS ONE, 13(1) (Art N° e0190612).-
item.accessRightsOpen Access-
item.contributorVan Keer, Karel-
item.contributorVan Keer, Jan-
item.contributorBreda, Joao Barbosa-
item.contributorNASSIRI, Vahid-
item.contributorDE DEYNE, Cathy-
item.contributorGENBRUGGE, Cornelia-
item.contributorPinto, Luis Abegao-
item.contributorStalmans, Ingeborg-
item.contributorVandewalle, Evelien-
item.fulltextWith Fulltext-
item.validationecoom 2019-
crisitem.journal.issn1932-6203-
crisitem.journal.eissn1932-6203-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
van keer 1.pdfPublished version6.04 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

3
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

5
checked on Apr 16, 2024

Page view(s)

52
checked on Sep 7, 2022

Download(s)

104
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.