Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/26904
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | NAWROT, Tim | - |
dc.contributor.advisor | RAES, Marc | - |
dc.contributor.author | Trippaers, Daphne | - |
dc.date.accessioned | 2018-10-03T10:03:54Z | - |
dc.date.available | 2018-10-03T10:03:54Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | http://hdl.handle.net/1942/26904 | - |
dc.description.abstract | Breathomics could be used as a new, objective and reliable tool to differentiate between multiple noisy breathing phenotypes. This could lead to earlier disease control and less mistreatment. Selected ion flow tube-mass spectrometry (SIFT-MS), a relatively new form of breathomics, can identify volatile organic compounds (VOCs) in exhaled breath and has great potential in biomarker research. The SIFT-MS was validated and compared to the current golden standard of gas analysis and breathomics, gas chromatography-mass spectrometry (GC-MS), using a peppermint washout experiment. After ingestion of a peppermint oil capsule, the washout of three peppermint compounds in exhaled breath was studied over time. Five individuals participated in this study. Validation parameters for the SIFT-MS were calculated prior to the actual benchmark study. Not all validation parameters were within range. The limit of detection was 9.92, 7.23, and 10.39ppb for eucalyptol, gamma-terpinene, and menthofuran, respectively. The measurement uncertainty for these VOCs was 33.12%, 69.62%, and 6.95%, respectively. These peppermint compounds were calculated during the benchmark study and did not show the typical decline of concentration over time. GC-MS could only detect eucalyptol but showed a better decline. The GC-MS showed better results than the SIFT-MS for eucalyptol, questioning the accuracy of this alternative breathomics technique. There is a need for further optimization and testing before the SIFT-MS can be implemented into the medical world. | - |
dc.format.mimetype | Application/pdf | - |
dc.language | nl | - |
dc.publisher | tUL | - |
dc.title | Validation of a new method for exhaled breath profiling in noisy breathing infants | - |
dc.type | Theses and Dissertations | - |
local.format.pages | 0 | - |
local.bibliographicCitation.jcat | T2 | - |
dc.description.notes | master in de biomedische wetenschappen-klinische moleculaire wetenschappen | - |
local.type.specified | Master thesis | - |
item.fulltext | With Fulltext | - |
item.fullcitation | Trippaers, Daphne (2018) Validation of a new method for exhaled breath profiling in noisy breathing infants. | - |
item.accessRights | Open Access | - |
item.contributor | Trippaers, Daphne | - |
Appears in Collections: | Master theses |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
dcd49620-24fb-4fc5-ac15-fb8176e2713a.pdf | 817.33 kB | Adobe PDF | View/Open |
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.