Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/2748
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCanet, MJM-
dc.contributor.authorHult, M-
dc.contributor.authorJohnston, PN-
dc.contributor.authorLAMBRICHTS, Ivo-
dc.date.accessioned2007-11-15T22:20:39Z-
dc.date.available2007-11-15T22:20:39Z-
dc.date.issued2001-
dc.identifier.citationRADIATION PROTECTION DOSIMETRY, 97(2). p. 169-172-
dc.identifier.issn0144-8420-
dc.identifier.urihttp://hdl.handle.net/1942/2748-
dc.description.abstractFollowing the use of in vivo measurements of Pb-210 to estimate retrospectively radon exposure, interest has been expressed in the use of in vivo measurements of (TI)-T-208 to estimate thorium intake, To aid with calibration and to determine the Optimum part of the body on which in vivo measurements should be made, the distribution of (TI)-T-208 and Ac-228 amongst different human bones was measured in the underground laboratory HADES, The (TI)-T-208 activity was determined by the 2614.5 keV and the 583.2 keV gamma ray lines, The Ac-228 activity was determined by the 911.2 keV and the 969.0 keV gamma ray lines, The back-round under those peaks when measured on the 106% relative efficiency coaxial HPGe detector in HADES is of the order of 1 d(-1), resulting in detection limits in the order of 1 mBq for both radionuclides for a typical 10 g bone sample and for a measuring time of 1 week.-
dc.language.isoen-
dc.publisherNUCLEAR TECHNOLOGY PUBL-
dc.titleUltra low-level gamma ray spectrometry of thorium in human bone samples-
dc.typeJournal Contribution-
dc.identifier.epage172-
dc.identifier.issue2-
dc.identifier.spage169-
dc.identifier.volume97-
local.format.pages4-
local.bibliographicCitation.jcatA1-
dc.description.notesCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium. Royal Melbourne Inst Technol, Dept Appl Phys, Melbourne, Vic 3001, Australia. Limburgs Univ Ctr, Dept Histol, Diepenbeek, Belgium.Hult, M, Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, Retieseweg, B-2440 Geel, Belgium.-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.isi000173654100015-
item.contributorCanet, MJM-
item.contributorHult, M-
item.contributorJohnston, PN-
item.contributorLAMBRICHTS, Ivo-
item.accessRightsClosed Access-
item.fullcitationCanet, MJM; Hult, M; Johnston, PN & LAMBRICHTS, Ivo (2001) Ultra low-level gamma ray spectrometry of thorium in human bone samples. In: RADIATION PROTECTION DOSIMETRY, 97(2). p. 169-172.-
item.validationecoom 2003-
item.fulltextNo Fulltext-
crisitem.journal.issn0144-8420-
crisitem.journal.eissn1742-3406-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.