Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/27596
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | VAN DER STRAATEN, Rob | - |
dc.contributor.author | BRUIJNES, Amber | - |
dc.contributor.author | Vanwanseele, Benedicte | - |
dc.contributor.author | Jonkers, Ilse | - |
dc.contributor.author | DE BAETS, Liesbet | - |
dc.contributor.author | TIMMERMANS, Annick | - |
dc.date.accessioned | 2019-01-17T14:49:26Z | - |
dc.date.available | 2019-01-17T14:49:26Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Sensors, 19 (1) (Art N° 141) | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | http://hdl.handle.net/1942/27596 | - |
dc.description.abstract | This study evaluates the reliability and agreement of the 3D range of motion (ROM) of trunk and lower limb joints, measured by inertial measurement units (MVN BIOMECH Awinda, Xsens Technologies), during a single leg squat (SLS) and sit to stand (STS) task. Furthermore, distinction was made between movement phases, to discuss the reliability and agreement for different phases of both movement tasks. Twenty healthy participants were measured on two testing days. On day one, measurements were conducted by two operators to determine the within-session and between-operator reliability and agreement. On day two, measurements were conducted by the same operator, to determine the between-session reliability and agreement. The SLS task had lower within-session reliability and agreement compared with between-session and between-operator reliability and agreement. The reliability and agreement of the hip, knee, and ankle ROM in the sagittal plane were good for both phases of the SLS task. For both phases of STS task, within-session reliability and agreement were good, and between-session and between-operator reliability and agreement were lower in all planes. As both tasks are physically demanding, differences may be explained by inconsistent movement strategies. These results show that inertial sensor systems show promise for use in further research to investigate (mal)adaptive movement strategies. | - |
dc.description.sponsorship | This study was funded by the Limburg Clinical Research Program (LCRP) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk, province of Limburg, Flemish government, Hasselt University, Ziekenhuis Oost-Limburg, and Jessa Hospital. The funding organizations did not have a contribution to the creation of this manuscript. | - |
dc.language.iso | en | - |
dc.rights | © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). | - |
dc.subject.other | inertial sensors; motion analysis; biomechanics; repeatability; functional movement | - |
dc.title | Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks | - |
dc.type | Journal Contribution | - |
dc.identifier.issue | 1 | - |
dc.identifier.volume | 19 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | van der Straaten, R (reprint author), Hasselt Univ, REVAL Rehabil Res Ctr, Agoralaan Bldg A, B-3560 Diepenbeek, Belgium. rob.vanderstraaten@uhasselt.be; amber.bruijnes@zol.be; benedicte.vanwanseele@kuleuven.be; ilse.jonkers@kuleuven.be; liesbet.debaets@uhasselt.be; annick.timmermans@uhasselt.be | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | 141 | - |
dc.identifier.doi | 10.3390/s19010141 | - |
dc.identifier.isi | 000458574600141 | - |
item.contributor | VAN DER STRAATEN, Rob | - |
item.contributor | BRUIJNES, Amber | - |
item.contributor | Vanwanseele, Benedicte | - |
item.contributor | Jonkers, Ilse | - |
item.contributor | DE BAETS, Liesbet | - |
item.contributor | TIMMERMANS, Annick | - |
item.fullcitation | VAN DER STRAATEN, Rob; BRUIJNES, Amber; Vanwanseele, Benedicte; Jonkers, Ilse; DE BAETS, Liesbet & TIMMERMANS, Annick (2019) Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks. In: Sensors, 19 (1) (Art N° 141). | - |
item.accessRights | Open Access | - |
item.fulltext | With Fulltext | - |
item.validation | ecoom 2020 | - |
crisitem.journal.eissn | 1424-8220 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
R. van der Straaten (2019) Reliability and Agreement of 3D Trunk and Lower Extremity Movement Analysis by Means of Inertial Sensor Technology for Unipodal and Bipodal Tasks.pdf | Published version | 2.84 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
3
checked on Sep 2, 2020
WEB OF SCIENCETM
Citations
15
checked on Apr 30, 2024
Page view(s)
110
checked on Sep 7, 2022
Download(s)
150
checked on Sep 7, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.