Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/27725| Title: | Between-session and inter-rater reliability of the modified tuck jump assessment in healthy adult athletes | Authors: | Gokeler, Alli DINGENEN, Bart |
Issue Date: | 2019 | Publisher: | Source: | Physical therapy in sport, 37, p. 10-14 | Abstract: | Objectives: This study aimed to determine the between-session and inter-rater reliability of the tuck jump assessment (TJA). Design: Reliability study Setting: Human movement laboratory Participants: Sixteen recreational participants (8 females, 8 males; mean age: 22.4 years) participated in the study. Participants performed the modified TJA in two sessions separated by one week. Main Outcome Measures: Between-session and inter-rater reliability were determined by two independent raters. The standard error of measurement (SEM) and smallest detectable difference (SDD) were calculated. Results: The between-session reliability for the total scores was excellent for rater 1 (ICC=0.93, 95% CI=0.78-0.98) and rater 2 (ICC=0.96, 95% CI=0.89-0.99), with SEM’s and SDD’s ranging between 0.5-0.7 and 1.3-2.1 respectively. The inter-rater reliability for the total scores was good for session 1 (ICC=0.85, 95% CI=0.58-0.95) and session 2 (ICC=0.88, 95% CI=0.66-0.96). In general, there was poor agreement for item analysis for both raters between sessions as well as between raters. Conclusion: The modified TJA revealed excellent between-session and good inter-rater reliability for the total score. Reliability for the between-session was poor for the individual items. The relatively poor reliability for the individual items imply that caution is warranted when solely interpreting the total score. | Notes: | Gokeler, A (reprint author), Luxembourg Inst Res Orthoped Sports Med & Sci LIR, 76 Rue Eich, L-1460 Luxembourg, Luxembourg. alli.gokeler@liroms.org | Keywords: | Neuromuscular control;Jumping;Screening/Exercise test;Rehabilitation;Reliability | Document URI: | http://hdl.handle.net/1942/27725 | ISSN: | 1466-853X | DOI: | 10.1016/j.ptsp.2019.02.002 | ISI #: | 000468716400002 | Rights: | 2019 Elsevier Ltd. All rights reserved. | Category: | A1 | Type: | Journal Contribution | Validations: | ecoom 2020 |
| Appears in Collections: | Research publications |
Show full item record
SCOPUSTM
Citations
7
checked on Oct 27, 2025
WEB OF SCIENCETM
Citations
7
checked on Oct 26, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.