Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/27928
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYALVAC, Burak-
dc.contributor.authorREULENS, Nathalie-
dc.contributor.authorRENIERS, Brigitte-
dc.date.accessioned2019-03-26T16:36:16Z-
dc.date.available2019-03-26T16:36:16Z-
dc.date.issued2019-
dc.identifier.citation34th BHPA Symposium, Aalst, Belgium, 1-2 February 2019-
dc.identifier.urihttp://hdl.handle.net/1942/27928-
dc.description.abstractBELdART is currently offering mailed audits for basic and complex dosimetry for a prostate case and intracranial SRS (SRS is sponsored by the College of Medicine Radiotherapy) using a combination of L-α-alanine-EPR and radiochromic dosimetry. For the prostate case, the Easycube phantom (Euromechanics Medical GmbH, Nürnberg, Germany) is used and for intracranial SRS the Stereotactic End-to-End Verification (STEEV) phantom (CIRS Inc., Norfolk, Virginia, USA). The phantoms preloaded with alanine and film detectors are sent to the centres as well as images of the phantoms and structure sets. Figure 1 shows the results for the basic tests. At the beginning of 2018, the 2x10-cm² test was replaced by a test of a 2x2-cm² field in solid water at 5 cm depth. The alanine dose and planned dose agree within 3 % for 97.4 % for the beam output and 97.06 %, 94.12 %, 97.06 % for 8cm, 20 cm and SSD85 respectively. For the other tests, they agree within 5 % except for small fields where 2 of the 27 beams show more than 5% discrepancy with the planned dose. For the complex dosimetry of the prostate case (Figure 2) all the centres are within 5% except 1 beam and for SRS 5 of the 6 beams are within 3 %. The gamma analysis of the films (Figure 3 and Table 1) shows that for the prostate case 86.3 % of the beams have a passing rate (3%/3mm) ≥ 95% and all 6 beams for SRS have a passing rate (5%/1mm) higher than ≥ 95%. The results are very good for all tests in general.-
dc.description.sponsorshipCollege van geneesheren voor de centra voor radiotherapie (Kankerplan)-
dc.language.isoen-
dc.subject.otherBELdART; SRS; Dosimetry audit; dose verification; VMAT; SBRT; EPR dosimetry; Film dosimetry-
dc.titleResults of external audits for basic and complex dosimetry for photon and electron beams from Oct 2016-
dc.typeConference Material-
local.bibliographicCitation.conferencedate1-2 February 2019-
local.bibliographicCitation.conferencename34th BHPA Symposium-
local.bibliographicCitation.conferenceplaceAalst, Belgium-
local.bibliographicCitation.jcatC2-
local.type.refereedNon-Refereed-
local.type.specifiedPresentation-
dc.identifier.urlhttp://www.bhpa2019.be/index.php?option=com_content&view=article&id=137:presentations-friday-1st-of-februari-big-room&catid=47&Itemid=541&lang=en-
item.fullcitationYALVAC, Burak; REULENS, Nathalie & RENIERS, Brigitte (2019) Results of external audits for basic and complex dosimetry for photon and electron beams from Oct 2016. In: 34th BHPA Symposium, Aalst, Belgium, 1-2 February 2019.-
item.contributorYALVAC, Burak-
item.contributorREULENS, Nathalie-
item.contributorRENIERS, Brigitte-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
BHPA2019_Abstract_Yalvac_Burak.pdfConference material445.44 kBAdobe PDFView/Open
Show simple item record

Page view(s)

36
checked on Sep 6, 2022

Download(s)

12
checked on Sep 6, 2022

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.