dc.description.abstractBackground: Electrocardiogram (ECG) contamination is present in diaphragm electromyography (EMGdi) recordings. Obtaining EMGdi without ECG contamination is crucial for EMG amplitude analysis. Manually selecting EMGdi in between QRS complexes has been most commonly applied in recent years (manual method). We developed a semi-automated analysis method based on Least Mean Square Adaptive Filtering combined with a synchronously recorded separate ECG channel to remove ECG artifacts from the EMGdi signals. We hypothesized that this approach would shorten analysis duration and might minimize the potential for inter-rater disagreement. Aims: We aimed to evaluate agreement between the semi-automated method and the manual method and inter-rater reliability of the manual method. Methods: EMGdi signals of seven patients with COPD were recorded using an esophageal catheter during an exercise test on a cycle ergometer. Four patients subsequently participated in an inspiratory muscle training (IMT) program for eight weeks. After IMT, the tests were repeated. EMGdi/EMGdiMax as obtained either manually by the two assessors or retrieved from the semi-automated method were compared. Results: Semi-automated EMGdi/EMGdiMax agreed well with values obtained by one of the two manual assessors (assessor 1) both at pre-intervention measurements (mean difference -0.5%, 95% CI -19.6% to 18.6%) and for the pre/post IMT differences (mean difference 1.2%, 95% CI -16.8% to 19.2%). Intra-class correlation coefficients between methods were 0.96 (95% CI: 0.94 to 0.97) at pre-intervention measurements and 0.78 (95% CI: 0.58 to 0.89) for pre/post IMT differences (both p<0.001). EMGdi/EMGdiMax from assessor 2 was systematically lower than from assessor 1 and agreed less well with the semi-automated method both at pre-intervention measurements (mean difference: 9.3%, 95% CI:-11.4% to 29.9%) and for pre/post IMT differences (mean difference 7.0%, 95% CI: -20.4% to 34.4%). Analysis duration of the semi-automated method was significantly shorter (29±9 minutes) than the manual method (82±20 minutes, p<0.001). Conclusion: The developed semi-automated method is more time efficient and will be less prone to inter-rater variability that was observed when applying the manual analysis method. It is, therefore, proposed as a new standard for objective EMGdi amplitude analyses in future studies.-
dc.description.sponsorshipThis research project was supported by the Research Foundation - Flanders (FWO): G0A4516N - ZKC9570 - C22/15/035. ZL is a recipient of an ERS fellowship (LTRF 2016-6686) and a postdoctoral research fellow of the FWO Flanders (12U5618N). AR is supported by the Coordination for the Improvement of Higher Education Personnel (CAPES), Brazil (88881.188754/2018-01). SD is supported by Chiang Mai University's scholarship, Chiang Mai, Thailand (Ref. No. 6392(7)/0807).-
dc.language.isoen-
dc.subject.otherelectromyography (EMG); electrocardiography (ECG); diaphragm electromyography; Chronic obstructive pulmonary disease (COPD); Respiratory muscle training-
dc.titleComparison between Manual and (Semi-) automated Analyses of Esophageal Diaphragm Electromyography during Endurance Cycling in Patients with COPD-
dc.typeJournal Contribution-
dc.identifier.volume10-
local.bibliographicCitation.jcatA1-
dc.description.notesLanger, D (reprint author), Katholieke Univ Leuven, Dept Rehabil Sci, Fac Movement & Rehabil Sci, Res Grp Rehabil Internal Disorders, Leuven, Belgium. daniel.langer@kuieuven.be-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr885-
dc.identifier.doi10.3389/fphys.2019.00885-
dc.identifier.isi000474804700001-
item.fulltextWith Fulltext-
item.fullcitationSauwaluk, Dacha; Janssens, Luc; Rodrigues, Antenor; Louvaris, Zafeiris; JANSSENS, Lotte; Gosselink, Rik & Langer, Daniel (2019) Comparison between Manual and (Semi-) automated Analyses of Esophageal Diaphragm Electromyography during Endurance Cycling in Patients with COPD. In: Frontiers in physiology, 10, Art N° 885.-
item.accessRightsOpen Access-
item.validationecoom 2020-
item.contributorSauwaluk, Dacha-
item.contributorJanssens, Luc-
item.contributorRodrigues, Antenor-
item.contributorLouvaris, Zafeiris-
item.contributorJANSSENS, Lotte-
item.contributorGosselink, Rik-
item.contributorLanger, Daniel-
crisitem.journal.eissn1664-042X-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
fphys-10-00885.pdfPublished version9.54 MBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

7
checked on May 8, 2024

Page view(s)

114
checked on Sep 7, 2022

Download(s)

82
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.