Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/28759
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bloem, Ada E. M. | - |
dc.contributor.author | Veltkamp, Marcel | - |
dc.contributor.author | SPRUIT, Martijn A. | - |
dc.contributor.author | Custers, Jan W. H. | - |
dc.contributor.author | Bakker, Eric W. P. | - |
dc.contributor.author | Dolk, Hanneke M. | - |
dc.contributor.author | Grutters, Jan C. | - |
dc.date.accessioned | 2019-07-18T12:00:42Z | - |
dc.date.available | 2019-07-18T12:00:42Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | SARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 35(4), p. 317-326 | - |
dc.identifier.issn | 1124-0490 | - |
dc.identifier.uri | http://hdl.handle.net/1942/28759 | - |
dc.description.abstract | Background and objective: Patients with pulmonary fibrosis (PF) have a clear exercise intolerance. The 4-meter-gait-speed (4MGS) test and the 5-repetitions-sit-to-stand (5STS) test are easy, inexpensive and reliable measures of functional performance. Both tests have been validated in healthy adults and patients with chronic obstructive pulmonary disease. 4MGS test and 5STS test have not been studied in patients with PF. Methods: In this cross-sectional clinimetric validation study 51 PF patients conducted in random order the 4MGS test, 5STS test and the 6-min walk test (6MWT) on a single day. Additionally, body weight, height, lean body mass, health-related quality of life, disease severity, handgrip strength, dyspnoea and leg fatigue were assessed. The setting was a tertiary referral center for Interstitial Lung Diseases. Results: Patients had a diagnosis of idiopathic pulmonary fibrosis (IPF, 37%), PF other than IPF (47%), or unclassified (16%). Patients walked 453 +/- 111m in six minutes. Moreover, it took the patients 2.0 +/- 0.5s to walk 4 m, and 12.0 +/- 3.8s for the 5STS test. The 4MGS test (r = 0.77; p<0.01) and the 5STS test (r = -0.41; p<0.01) correlated significantly with the distance walked in 6MWT. Indeed, 4MGS combined with handgrip strength and Medical Research Council dyspnoea grade could explain 75% of the variance in 6MWD. Conclusions: 4-meter-gait-speed and 5-repetitions sit-to-stand are significantly and independently correlated with the 6-minute walk distance in patients with pulmonary fibrosis. Indeed, 4-meter-gait-speed test may serve as a simple initial field test to assess exercise performance in patients with pulmonary fibrosis. | - |
dc.language.iso | en | - |
dc.publisher | MATTIOLI 1885 | - |
dc.rights | Mattioli 1885 | - |
dc.subject.other | exercise and pulmonary rehabilitation; pulmonary fibrosis; 6-minute walk test; gait | - |
dc.subject.other | exercise and pulmonary rehabilitation; pulmonary fibrosis; 6-minute walk test; gait | - |
dc.title | VALIDATION OF 4-METER-GAIT-SPEED TEST AND 5-REPETITIONS-SIT-TO-STAND TEST IN PATIENTS WITH PULMONARY FIBROSIS: A CLINIMETRIC VALIDATION STUDY | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 326 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 317 | - |
dc.identifier.volume | 35 | - |
local.format.pages | 10 | - |
local.bibliographicCitation.jcat | A1 | - |
dc.description.notes | [Bloem, Ada E. M.; Custers, Jan W. H.] Univ Appl Sci Utrecht, Fac Hlth Care, Inst Movement Studies, Utrecht, Netherlands. [Veltkamp, Marcel; Dolk, Hanneke M.; Grutters, Jan C.] St Antonius Hosp, Dept Pulmonol, Interstitial Lung Dis Ctr Excellence, Nieuwegein, Netherlands. [Veltkamp, Marcel; Dolk, Hanneke M.; Grutters, Jan C.] Univ Med Ctr Utrecht, Div Heart & Lungs, Utrecht, Netherlands. [Spruit, Martijn A.] Ctr Expertise Chron Organ Failure, CIRO, Dept Res & Educ, Horn, Netherlands. [Spruit, Martijn A.] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, Dept Resp Med, Maastricht, Netherlands. [Spruit, Martijn A.] Hasselt Univ, Fac Med & Life Sci, BIOMED Biomed Res Inst, REVAL Rehabil Res Ctr, Diepenbeek, Belgium. [Bakker, Eric W. P.] Acad Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands. | - |
local.publisher.place | FIDENZA | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.identifier.isi | 000452167600004 | - |
item.accessRights | Restricted Access | - |
item.contributor | Bloem, Ada E. M. | - |
item.contributor | Veltkamp, Marcel | - |
item.contributor | SPRUIT, Martijn A. | - |
item.contributor | Custers, Jan W. H. | - |
item.contributor | Bakker, Eric W. P. | - |
item.contributor | Dolk, Hanneke M. | - |
item.contributor | Grutters, Jan C. | - |
item.fulltext | With Fulltext | - |
item.fullcitation | Bloem, Ada E. M.; Veltkamp, Marcel; SPRUIT, Martijn A.; Custers, Jan W. H.; Bakker, Eric W. P.; Dolk, Hanneke M. & Grutters, Jan C. (2018) VALIDATION OF 4-METER-GAIT-SPEED TEST AND 5-REPETITIONS-SIT-TO-STAND TEST IN PATIENTS WITH PULMONARY FIBROSIS: A CLINIMETRIC VALIDATION STUDY. In: SARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 35(4), p. 317-326. | - |
item.validation | ecoom 2019 | - |
crisitem.journal.issn | 1124-0490 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
7035-Article Text-28028-3-10-20181203.pdf Restricted Access | Published version | 675.63 kB | Adobe PDF | View/Open Request a copy |
WEB OF SCIENCETM
Citations
5
checked on Apr 16, 2024
Page view(s)
14
checked on Sep 6, 2022
Download(s)
4
checked on Sep 6, 2022
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.