Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/28759
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBloem, Ada E. M.-
dc.contributor.authorVeltkamp, Marcel-
dc.contributor.authorSPRUIT, Martijn A.-
dc.contributor.authorCusters, Jan W. H.-
dc.contributor.authorBakker, Eric W. P.-
dc.contributor.authorDolk, Hanneke M.-
dc.contributor.authorGrutters, Jan C.-
dc.date.accessioned2019-07-18T12:00:42Z-
dc.date.available2019-07-18T12:00:42Z-
dc.date.issued2018-
dc.identifier.citationSARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 35(4), p. 317-326-
dc.identifier.issn1124-0490-
dc.identifier.urihttp://hdl.handle.net/1942/28759-
dc.description.abstractBackground and objective: Patients with pulmonary fibrosis (PF) have a clear exercise intolerance. The 4-meter-gait-speed (4MGS) test and the 5-repetitions-sit-to-stand (5STS) test are easy, inexpensive and reliable measures of functional performance. Both tests have been validated in healthy adults and patients with chronic obstructive pulmonary disease. 4MGS test and 5STS test have not been studied in patients with PF. Methods: In this cross-sectional clinimetric validation study 51 PF patients conducted in random order the 4MGS test, 5STS test and the 6-min walk test (6MWT) on a single day. Additionally, body weight, height, lean body mass, health-related quality of life, disease severity, handgrip strength, dyspnoea and leg fatigue were assessed. The setting was a tertiary referral center for Interstitial Lung Diseases. Results: Patients had a diagnosis of idiopathic pulmonary fibrosis (IPF, 37%), PF other than IPF (47%), or unclassified (16%). Patients walked 453 +/- 111m in six minutes. Moreover, it took the patients 2.0 +/- 0.5s to walk 4 m, and 12.0 +/- 3.8s for the 5STS test. The 4MGS test (r = 0.77; p<0.01) and the 5STS test (r = -0.41; p<0.01) correlated significantly with the distance walked in 6MWT. Indeed, 4MGS combined with handgrip strength and Medical Research Council dyspnoea grade could explain 75% of the variance in 6MWD. Conclusions: 4-meter-gait-speed and 5-repetitions sit-to-stand are significantly and independently correlated with the 6-minute walk distance in patients with pulmonary fibrosis. Indeed, 4-meter-gait-speed test may serve as a simple initial field test to assess exercise performance in patients with pulmonary fibrosis.-
dc.language.isoen-
dc.publisherMATTIOLI 1885-
dc.rightsMattioli 1885-
dc.subject.otherexercise and pulmonary rehabilitation; pulmonary fibrosis; 6-minute walk test; gait-
dc.subject.otherexercise and pulmonary rehabilitation; pulmonary fibrosis; 6-minute walk test; gait-
dc.titleVALIDATION OF 4-METER-GAIT-SPEED TEST AND 5-REPETITIONS-SIT-TO-STAND TEST IN PATIENTS WITH PULMONARY FIBROSIS: A CLINIMETRIC VALIDATION STUDY-
dc.typeJournal Contribution-
dc.identifier.epage326-
dc.identifier.issue4-
dc.identifier.spage317-
dc.identifier.volume35-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notes[Bloem, Ada E. M.; Custers, Jan W. H.] Univ Appl Sci Utrecht, Fac Hlth Care, Inst Movement Studies, Utrecht, Netherlands. [Veltkamp, Marcel; Dolk, Hanneke M.; Grutters, Jan C.] St Antonius Hosp, Dept Pulmonol, Interstitial Lung Dis Ctr Excellence, Nieuwegein, Netherlands. [Veltkamp, Marcel; Dolk, Hanneke M.; Grutters, Jan C.] Univ Med Ctr Utrecht, Div Heart & Lungs, Utrecht, Netherlands. [Spruit, Martijn A.] Ctr Expertise Chron Organ Failure, CIRO, Dept Res & Educ, Horn, Netherlands. [Spruit, Martijn A.] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, Dept Resp Med, Maastricht, Netherlands. [Spruit, Martijn A.] Hasselt Univ, Fac Med & Life Sci, BIOMED Biomed Res Inst, REVAL Rehabil Res Ctr, Diepenbeek, Belgium. [Bakker, Eric W. P.] Acad Med Ctr, Dept Clin Epidemiol Biostat & Bioinformat, Amsterdam, Netherlands.-
local.publisher.placeFIDENZA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.identifier.isi000452167600004-
item.accessRightsRestricted Access-
item.contributorBloem, Ada E. M.-
item.contributorVeltkamp, Marcel-
item.contributorSPRUIT, Martijn A.-
item.contributorCusters, Jan W. H.-
item.contributorBakker, Eric W. P.-
item.contributorDolk, Hanneke M.-
item.contributorGrutters, Jan C.-
item.fulltextWith Fulltext-
item.fullcitationBloem, Ada E. M.; Veltkamp, Marcel; SPRUIT, Martijn A.; Custers, Jan W. H.; Bakker, Eric W. P.; Dolk, Hanneke M. & Grutters, Jan C. (2018) VALIDATION OF 4-METER-GAIT-SPEED TEST AND 5-REPETITIONS-SIT-TO-STAND TEST IN PATIENTS WITH PULMONARY FIBROSIS: A CLINIMETRIC VALIDATION STUDY. In: SARCOIDOSIS VASCULITIS AND DIFFUSE LUNG DISEASES, 35(4), p. 317-326.-
item.validationecoom 2019-
crisitem.journal.issn1124-0490-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
7035-Article Text-28028-3-10-20181203.pdf
  Restricted Access
Published version675.63 kBAdobe PDFView/Open    Request a copy
Show simple item record

WEB OF SCIENCETM
Citations

5
checked on Apr 16, 2024

Page view(s)

14
checked on Sep 6, 2022

Download(s)

4
checked on Sep 6, 2022

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.