dc.description.abstractMolecular diagnostics are very attractive tools for pathogen detection. But, the conventional molecular diagnostics are unsuitable for poor point of care (POC). So, miniaturizing lab devices towards a Lab-on-card (LOC) is useful in POC. We aimed to translate macro-lab techniques to a single LOC sensor for cell lysis & DNA extraction, amplification & detection using Loop-Mediated isothermal amplification (LAMP). LAMP is sensitive, cheap, rapid and very appealing for POC. So, we hypothesized “LAMP can be incorporated for the development of a LOC sensor for DNA extraction, amplification and detection”.The next goals were tested on card: cell extraction, cell lysis & DNA extraction, mixing samples &reagents, and optical DNA detection. A card was designed to test each step separately. Artificial sputum is prepared & liquified by hot water. Cells were extracted by filter paper. Thermal cell lysis was tested by microheater & DNA extraction was estimated by Nanodrop. A micromixer is tested to mix the reagents. The detection of the DNA amplicons was performed by a photosensor on card. Here we provided cards that can, extract cells in sputum, rupture cells and extract DNA thermally, mix sample and reagents, detect the DNA by a photosensor. Each step was tested on card separately.To conclude, each step of the DNA sensor was performed by LOC. Hence, the development of a single DNA card sensor is very promising which is of great value in POC & remote settings-
dc.format.mimetypeApplication/pdf-
dc.languageen-
dc.publishertUL-
dc.titleLab-on-card based sensor for DNA detection using Loop-mediated isothermal amplification-
dc.typeTheses and Dissertations-
local.format.pages0-
local.bibliographicCitation.jcatT2-
dc.description.notesMaster of Biomedical Sciences-Environmental Health Sciences-
local.type.specifiedMaster thesis-
item.fulltextWith Fulltext-
item.accessRightsOpen Access-
item.contributorZain, Ashwaq-
item.fullcitationZain, Ashwaq (2019) Lab-on-card based sensor for DNA detection using Loop-mediated isothermal amplification.-
Appears in Collections:Master theses
Files in This Item:
File Description SizeFormat 
551122ee-5287-4257-a2a6-2a31fefb821e.pdf1.98 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.