Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/2934
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMEYKENS, Kristien-
dc.contributor.authorHAENEN, Ken-
dc.contributor.authorNESLADEK, Milos-
dc.contributor.authorSTALS, Lambert-
dc.contributor.authorPickles, CSJ-
dc.contributor.authorSussmann, RS-
dc.date.accessioned2007-11-20T13:52:59Z-
dc.date.available2007-11-20T13:52:59Z-
dc.date.issued2000-
dc.identifier.citationDIAMOND AND RELATED MATERIALS, 9(3-6). p. 1021-1025-
dc.identifier.issn0925-9635-
dc.identifier.urihttp://hdl.handle.net/1942/2934-
dc.description.abstractThe quasi-parallel collinear photothermal deflection (PTD) technique was applied to the investigation of the optical absorption coefficient at the CO2 laser wavelength (10.6 mu m) for a set of chemical vapour deposited (CVD) diamond windows of various optical qualities. The PTD measurements enabled absorption imaging to be performed and thus the mechanism of optical absorption in CVD diamond to be studied. For the measured samples, the optical absorption is affected by the black non-diamond inclusions, which are - to a greater or lesser extent, depending on the material grade - present in all CVD diamond films. The optical grade material contains just a few of these inclusions. To obtain absolute values of the optical absorption, the relative PTD Values were calibrated by using a sample with known absorption (measured by laser calorimetry). The mathematical simulations were carried out using a theoretical model for the temperature (heat diffusion) profile in diamond, which yielded a very good agreement with the experimental results. (C) 2000 Elsevier Science S.A. All rights reserved.-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.subject.otherabsorption; defect; infrared; laser-
dc.titleMeasurement and mapping of very low optical absorption of CVD diamond IR windows-
dc.typeJournal Contribution-
dc.identifier.epage1025-
dc.identifier.issue3-6-
dc.identifier.spage1021-
dc.identifier.volume9-
local.format.pages5-
local.bibliographicCitation.jcatA1-
dc.description.notesLimburgs Univ Ctr, Inst Mat Res, B-3590 Diepenbeek, Belgium.Meykens, K, Limburgs Univ Ctr, Inst Mat Res, Univ Campus,Wetenschapspk 1, B-3590 Diepenbeek, Belgium.-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.bibliographicCitation.oldjcatA1-
dc.identifier.doi10.1016/S0925-9635(99)00222-8-
dc.identifier.isi000087382400159-
item.accessRightsClosed Access-
item.fullcitationMEYKENS, Kristien; HAENEN, Ken; NESLADEK, Milos; STALS, Lambert; Pickles, CSJ & Sussmann, RS (2000) Measurement and mapping of very low optical absorption of CVD diamond IR windows. In: DIAMOND AND RELATED MATERIALS, 9(3-6). p. 1021-1025.-
item.contributorMEYKENS, Kristien-
item.contributorHAENEN, Ken-
item.contributorNESLADEK, Milos-
item.contributorSTALS, Lambert-
item.contributorPickles, CSJ-
item.contributorSussmann, RS-
item.fulltextNo Fulltext-
item.validationecoom 2001-
Appears in Collections:Research publications
Show simple item record

SCOPUSTM   
Citations

16
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

15
checked on Apr 22, 2024

Page view(s)

58
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.