Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/30395
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMARTENS, Pieter-
dc.contributor.authorDEFERM, Sebastien-
dc.contributor.authorBERTRAND, Philippe-
dc.contributor.authorVERBRUGGE, Frederik-
dc.contributor.authorRamaekers, Jobbe-
dc.contributor.authorVerhaert, David-
dc.contributor.authorDUPONT, Matthias-
dc.contributor.authorVANDERVOORT, Pieter-
dc.contributor.authorMULLENS, Wilfried-
dc.date.accessioned2020-01-24T10:05:22Z-
dc.date.available2020-01-24T10:05:22Z-
dc.date.issued2020-
dc.date.submitted2020-01-23T11:58:21Z-
dc.identifier.citationJACC: Cardiovascular Imaging, 13 (4), p. 895-906-
dc.identifier.issn1936-878X-
dc.identifier.urihttp://hdl.handle.net/1942/30395-
dc.description.abstractOBJECTIVES This study assessed the impact of right-atrial (RA) pacing on left-atrial (LA) physiology and clinical outcome. BACKGROUND Data for the effects of RA pacing on LA synchronicity, function, and structure after cardiac resynchronization therapy (CRT) are scarce. METHODS The effect of RA pacing on LA function, morphology, and synchronicity was assessed in a prospective imaging cohort of heart failure (HF) patients in sinus rhythm with a guideline-based indication for CRT. Additionally, in a retrospective outcome cohort of consecutive HF patients undergoing CRT implantation, the relationship to RA pacing was assessed using various outcome endpoints. High versus low atrial pacing burden was defined as atrial pacing above or below 50% in both cohorts. RESULTS A total of 36 patients were included in the imaging cohort (68 11 years of age). Six months after CRT, patients with high RA pacing burden showed less improvement in LA maximum and minimum volumes and total emptying fraction (p < 0.05). Peak atrial longitudinal strain and reservoir and booster strain rates but not conduit strain rate improved after CRT in patients with low RA pacing burden but worsened in patients with high RA pacing burden (p < 0.05 for all). A high RA pacing burden induced significant intra-atrial dyssynchrony (maximum opposing wall delay: 44 13 ms vs. 97 17 ms, respectively; p ¼ 0.022). A total of 569 patients were included in the outcome cohort. After covariate adjustments were made, a high RA pacing burden was associated with reduced LV reverse remodeling (b ¼ 8.738; 95% confidence interval [CI]: 3.101 to 14.374; p ¼ 0.002) and new-onset or recurrent atrial fibrillation (41% vs. 22%, respectively, at a median of 31 months [range 22 to 44 months follow-up]; p < 0.001). There were no differences in time to first HF hospitalization or all-cause mortality (p ¼ 0.185) after covariate adjustment. However, in a recurrent event analysis, HF readmissions were more common in patients exposed to a high RA pacing burden (p ¼ 0.003). CONCLUSIONS RA pacing in CRT patients negatively influences LA morphology, function, and synchronicity, which is associated with worse clinical outcome, including diminished LV reverse remodeling, increased risk for new-onset or recurrent AF and heart failure readmission. Strategies reducing RA pacing burden may be warranted.-
dc.description.sponsorshipDr. Martens is supported by Research Foundation-Flanders doctoral fellowship grant 1127917N. Dr. Martens, Deferm, and Mullens are researchers for the Limburg Clinical Research Program, supported by Limburg Sterk Merk, Hasselt University, Ziekenhuis Oost-Limburg and Jessa Hospital.-
dc.language.isoen-
dc.publisherElsevier B.V.-
dc.rights2019 by the American College of Cardiology Foundation.-
dc.subject.otheratrial fibrillation-
dc.subject.othercardiac resynchronization therapy-
dc.subject.otherleft atrial function-
dc.subject.otherreverse remodeling-
dc.subject.otherright atrial pacing-
dc.titleThe Detrimental Effect of RA Pacing on LA Function and Clinical Outcome in Cardiac Resynchronization Therapy-
dc.typeJournal Contribution-
dc.identifier.epage906-
dc.identifier.issue4-
dc.identifier.spage895-
dc.identifier.volume13-
local.bibliographicCitation.jcatA1-
local.publisher.placeAmsterdam, the Netherland-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.source.typeArticle-
dc.identifier.doi10.1016/j.jcmg.2019.04.022-
dc.identifier.pmid31326478-
dc.identifier.isiWOS:000523658100001-
dc.identifier.eissn1876-7591-
local.provider.typePdf-
local.uhasselt.uhpubyes-
local.uhasselt.internationalno-
item.validationecoom 2021-
item.contributorMARTENS, Pieter-
item.contributorDEFERM, Sebastien-
item.contributorBERTRAND, Philippe-
item.contributorVERBRUGGE, Frederik-
item.contributorRamaekers, Jobbe-
item.contributorVerhaert, David-
item.contributorDUPONT, Matthias-
item.contributorVANDERVOORT, Pieter-
item.contributorMULLENS, Wilfried-
item.accessRightsOpen Access-
item.fullcitationMARTENS, Pieter; DEFERM, Sebastien; BERTRAND, Philippe; VERBRUGGE, Frederik; Ramaekers, Jobbe; Verhaert, David; DUPONT, Matthias; VANDERVOORT, Pieter & MULLENS, Wilfried (2020) The Detrimental Effect of RA Pacing on LA Function and Clinical Outcome in Cardiac Resynchronization Therapy. In: JACC: Cardiovascular Imaging, 13 (4), p. 895-906.-
item.fulltextWith Fulltext-
crisitem.journal.issn1936-878X-
crisitem.journal.eissn1876-7591-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
PRESSVERSION_RAPACINGandLAfunction (1).pdfPublished version950.65 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

1
checked on Sep 5, 2020

WEB OF SCIENCETM
Citations

13
checked on Apr 30, 2024

Page view(s)

48
checked on Jul 14, 2022

Download(s)

4
checked on Jul 14, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.