Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/30668
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBevers, Melissa S. A. M.-
dc.contributor.authorDaniels, Anne M.-
dc.contributor.authorWyers, Caroline E.-
dc.contributor.authorvan Rietbergen, Bert-
dc.contributor.authorGEUSENS, Piet-
dc.contributor.authorKaarsemaker, Sjoerd-
dc.contributor.authorJanzing, Heinrich M. J.-
dc.contributor.authorHannemann, Pascal F. W.-
dc.contributor.authorPoeze, Martijn-
dc.contributor.authorVAN DEN BERGH, Joop-
dc.date.accessioned2020-03-04T11:36:30Z-
dc.date.available2020-03-04T11:36:30Z-
dc.date.issued2019-
dc.date.submitted2020-03-04T11:23:46Z-
dc.identifier.citationJOURNAL OF BONE AND MINERAL RESEARCH, 34 , p. 293 -294-
dc.identifier.issn0884-0431-
dc.identifier.urihttp://hdl.handle.net/1942/30668-
dc.description.abstractINTRODUCTION: Diagnosing scaphoid fractures remains challenging. High-resolution peripheral quantitative computed tomography (HR-pQCT) might be a potential imaging technique, but no data are available on its feasibility to scan the scaphoid bone in vivo. METHODOLOGY: Patients (≥18 years) with a clinically suspected scaphoid fracture received an HR-pQCT scan of the scaphoid bone (three 10.2-mm stacks, 61-μm voxel size) with their wrist immobilized with a cast. Scan quality assessment and bone contouring were performed using methods originally developed for HR-pQCT scans of radius and tibia. The contouring algorithm was applied on coarse hand-drawn pre-contours of the scaphoid bone, and the resulting contours (AUTO) were manually corrected (sAUTO) when visually deviating from bone margins. Standard morphologic analyses were performed on the AUTO- and sAUTO-contoured bones. RESULTS: Ninety-one patients were scanned. Two out of the first five scans were repeated due to poor scan quality (40%) based on standard quality assessment during scanning, which decreased to three out of the next 86 scans (3.5%) when using an additional thumb cast. Nevertheless, after excluding one scan with an incompletely scanned scaphoid bone, post hoc grading revealed a poor quality in 14.9% of the stacks and 32.9% of the scans in the remaining 85 patients. After excluding two scans with contouring problems due to scan quality, bone indices obtained by AUTO- and sAUTO-contouring were compared in 83 scans. All AUTO-contours were manually corrected, resulting in significant but small differences in densitometric and trabecular indices (<1.0%). CONCLUSIONS: In vivo HR-pQCT scanning of the scaphoid bone is feasible in patients with a clinically suspected scaphoid fracture when using a cast with thumb part. The proportion of poor-quality stacks is similar to radius scans, and AUTO-contouring appears appropriate in good- and poor-quality scans . Thus, HR-pQCT may be promising for diagnosis of and microarchitectural evaluations in suspected scaphoid fractures.-
dc.language.isoen-
dc.publisherWILEY-
dc.rights2019 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.-
dc.subject.otherautomatic contouring algorithm-
dc.subject.otherhigh-resolution peripheral quantitative computed tomography-
dc.subject.otherin vivo imaging-
dc.subject.otherscan quality-
dc.subject.otherscaphoid fracture-
dc.titleThe feasibility of high-resolution peripheral quantitative computed tomography (HR-pQCT) in patients with a suspected scaphoid fracture-
dc.typeJournal Contribution-
local.bibliographicCitation.conferencedateSEP 20-23, 2019-
local.bibliographicCitation.conferencenameAnnual Meeting of the American-Society-for-Bone-and Mineral Research-
local.bibliographicCitation.conferenceplaceOrlando, FL-
dc.identifier.epage294-
dc.identifier.spage293-
dc.identifier.volume34-
local.format.pages2-
local.bibliographicCitation.jcatM-
local.publisher.place111 RIVER ST, HOBOKEN 07030-5774, NJ USA-
local.type.refereedRefereed-
local.type.specifiedMeeting Abstract-
dc.identifier.pmid31495579-
dc.identifier.isiWOS:000508356604009-
dc.identifier.eissn1523-4681-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.uhasselt.internationalyes-
item.contributorBevers, Melissa S. A. M.-
item.contributorDaniels, Anne M.-
item.contributorWyers, Caroline E.-
item.contributorvan Rietbergen, Bert-
item.contributorGEUSENS, Piet-
item.contributorKaarsemaker, Sjoerd-
item.contributorJanzing, Heinrich M. J.-
item.contributorHannemann, Pascal F. W.-
item.contributorPoeze, Martijn-
item.contributorVAN DEN BERGH, Joop-
item.fullcitationBevers, Melissa S. A. M.; Daniels, Anne M.; Wyers, Caroline E.; van Rietbergen, Bert; GEUSENS, Piet; Kaarsemaker, Sjoerd; Janzing, Heinrich M. J.; Hannemann, Pascal F. W.; Poeze, Martijn & VAN DEN BERGH, Joop (2019) The feasibility of high-resolution peripheral quantitative computed tomography (HR-pQCT) in patients with a suspected scaphoid fracture. In: JOURNAL OF BONE AND MINERAL RESEARCH, 34 , p. 293 -294.-
item.accessRightsClosed Access-
item.fulltextNo Fulltext-
crisitem.journal.issn0884-0431-
crisitem.journal.eissn1523-4681-
Appears in Collections:Research publications
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.