Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/30872
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLongfils, Marco-
dc.contributor.authorSMISDOM, Nick-
dc.contributor.authorAMELOOT, Marcel-
dc.contributor.authorRudemo, Mats-
dc.contributor.authorLEMMENS, Veerle-
dc.contributor.authorFernandez, Guillermo Solis-
dc.contributor.authorRoding, Magnus-
dc.contributor.authorLoren, Niklas-
dc.contributor.authorHENDRIX, Jelle-
dc.contributor.authorSarkka, Aila-
dc.date.accessioned2020-03-23T13:48:25Z-
dc.date.available2020-03-23T13:48:25Z-
dc.date.issued2019-
dc.date.submitted2020-01-29T14:28:27Z-
dc.identifier.citationBIOPHYSICAL JOURNAL, 117 (10) , p. 1900 -1914-
dc.identifier.urihttp://hdl.handle.net/1942/30872-
dc.description.abstractRaster image correlation spectroscopy (RICS) is a fluorescence image analysis method for extracting the mobility, concentration, and stoichiometry of diffusing fluorescent molecules from confocal image stacks. The method works by calculating a spatial correlation function for each image and analyzing the average of those by model fitting. Rules of thumb exist for RICS image acquisitioning, yet a rigorous theoretical approach to predict the accuracy and precision of the recovered parameters has been lacking. We outline explicit expressions to reveal the dependence of RICS results on experimental parameters. In terms of imaging settings, we observed that a twofold decrease of the pixel size, e.g., from 100 to 50 nm, decreases the error on the translational diffusion constant (D) between three- and fivefold. For D = 1 mu m(2) s(-1), a typical value for intracellular measurements, similar to 25-fold lower mean-squared relative error was obtained when the optimal scan speed was used, although more drastic improvements were observed for other values of D. We proposed a slightly modified RICS calculation that allows correcting for the significant bias of the autocorrelation function at small (<<50 x 50 pixels) sizes of the region of interest. In terms of sample properties, at molecular brightness E = 100 kHz and higher, RICS data quality was sufficient using as little as 20 images, whereas the optimal number of frames for lower E scaled pro rata. RICS data quality was constant over the nM-mM concentration range. We developed a bootstrap-based confidence interval of D that outperformed the classical leastsquares approach in terms of coverage probability of the true value of D. We validated the theory via in vitro experiments of enhanced green fluorescent protein at different buffer viscosities. Finally, we outline robust practical guidelines and provide free software to simulate the parameter effects on recovery of the diffusion coefficient.-
dc.description.sponsorshipFinancial support from the Swedish Foundation for Strategic Research and Knut and AliceWallenberg Foundation is highly appreciated. J.H. acknowledges the KU Leuven for funding (C14/16/053). V.L. acknowledges the UHasselt Bijzonder Onderzoeksfonds fund (BOF17DOC11) for a PhD scholarship. Guillermo Soli ' s Ferna ' ndez is grateful for a PhD scholarship from the Research Foundation Flanders.-
dc.language.isoen-
dc.publisherCELL PRESS-
dc.rights2019 Biophysical Society.-
dc.subject.otherFluorescence Correlation Spectroscopy-
dc.subject.otherStatistical-Analysis-
dc.subject.otherStandard-Deviation-
dc.subject.otherDiffusion-
dc.subject.otherRics-
dc.subject.otherDynamics-
dc.subject.otherCells-
dc.titleRaster Image Correlation Spectroscopy Performance Evaluation-
dc.typeJournal Contribution-
dc.identifier.epage1914-
dc.identifier.issue10-
dc.identifier.spage1900-
dc.identifier.volume117-
local.format.pages15-
local.bibliographicCitation.jcatA1-
dc.description.notesLongfils, M (reprint author), Chalmers Univ Technol, Dept Math Sci, Gothenburg, Sweden.; Longfils, M (reprint author), Univ Gothenburg, Gothenburg, Sweden.; Hendrix, J (reprint author), Hasselt Univ, Adv Opt Microscopy Ctr, Biomed Res Inst, Diepenbeek, Belgium.; Hendrix, J (reprint author), Hasselt Univ, Dynam Bioimaging Lab, Diepenbeek, Belgium.-
dc.description.noteslongfils@chalmers.se; jelle.hendrix@uhasselt.be-
dc.description.otherLongfils, M (reprint author), Chalmers Univ Technol, Dept Math Sci, Gothenburg, Sweden, Univ Gothenburg, Gothenburg, Sweden. Hendrix, J (reprint author), Hasselt Univ, Adv Opt Microscopy Ctr, Biomed Res Inst, Diepenbeek, Belgium, Hasselt Univ, Dynam Bioimaging Lab, Diepenbeek, Belgium. longfils@chalmers.se; jelle.hendrix@uhasselt.be-
local.publisher.place50 HAMPSHIRE ST, FLOOR 5, CAMBRIDGE, MA 02139 USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.source.typeArticle-
dc.identifier.doi10.1016/j.bpj.2019.09.045-
dc.identifier.pmid31668746-
dc.identifier.isiWOS:000497815800012-
dc.identifier.eissn1542-0086-
local.provider.typewosris-
local.uhasselt.uhpubyes-
item.validationecoom 2020-
item.fullcitationLongfils, Marco; SMISDOM, Nick; AMELOOT, Marcel; Rudemo, Mats; LEMMENS, Veerle; Fernandez, Guillermo Solis; Roding, Magnus; Loren, Niklas; HENDRIX, Jelle & Sarkka, Aila (2019) Raster Image Correlation Spectroscopy Performance Evaluation. In: BIOPHYSICAL JOURNAL, 117 (10) , p. 1900 -1914.-
item.contributorLongfils, Marco-
item.contributorSMISDOM, Nick-
item.contributorAMELOOT, Marcel-
item.contributorRudemo, Mats-
item.contributorLEMMENS, Veerle-
item.contributorFernandez, Guillermo Solis-
item.contributorRoding, Magnus-
item.contributorLoren, Niklas-
item.contributorHENDRIX, Jelle-
item.contributorSarkka, Aila-
item.accessRightsClosed Access-
item.fulltextNo Fulltext-
crisitem.journal.issn0006-3495-
crisitem.journal.eissn1542-0086-
Appears in Collections:Research publications
Show simple item record

SCOPUSTM   
Citations

4
checked on Sep 7, 2020

WEB OF SCIENCETM
Citations

7
checked on May 8, 2024

Page view(s)

60
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.