dc.identifier.citationJournal of Maternal-Fetal & Neonatal Medicine, 33 (9) , p. 1625 -1627-
dc.identifier.urihttp://hdl.handle.net/1942/30900-
dc.description.abstractIntrathoracic impedance was remotely monitored from preconception to postpartum in a woman with an implantable cardioverter defibrillator. At 6 and 20 weeks, two significant changes were recorded, suggestive for thoracic fluid accumulation. After normal outcome, postpartum intrathoracic impedance returned to preconception values. The obtained results from this case report show that these measurements can be obtained with an implanted device. Current devices for measuring cardiac output by impedance technique allow evaluating thoracic fluid changes non-invasively. As such, non-invasive impedance monitoring may be a potential new method for continuous monitoring of maternal vascular changes during any time window between preconception and postpartum, to be assessed in a large cross sectional observational study.-
dc.description.sponsorshipThis report is part of the Limburg Clinical Research Program (LCRP) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk (LSM), Hasselt University, Ziekenhuis Oost-Limburg, and Jessa Hospital. No specific funding was provided for publication of this case report.-
dc.language.isoen-
dc.publisherTAYLOR & FRANCIS LTD-
dc.subject.otherIntrathoracic impedance-
dc.subject.othermaternal hemodynamic changes in pregnancy-
dc.subject.otherremote monitoring-
dc.titleIntrathoracic fluid changes from preconception to postpartum as measured by bio-impedance monitoring-
dc.typeJournal Contribution-
dc.identifier.epage1627-
dc.identifier.issue9-
dc.identifier.spage1625-
dc.identifier.volume33-
local.format.pages3-
local.bibliographicCitation.jcatA1-
dc.description.notesLanssens, D (reprint author), Ziekenhuis Oost Limburg, Dept Gynaecol, Schiepse Bos 6, Genk, Belgium.-
dc.description.notesdorien.lanssens@uhasselt.be-
dc.description.otherLanssens, D (reprint author), Ziekenhuis Oost Limburg, Dept Gynaecol, Schiepse Bos 6, Genk, Belgium. dorien.lanssens@uhasselt.be-
local.publisher.place2-4 PARK SQUARE, MILTON PARK, ABINGDON OR14 4RN, OXON, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.source.typeArticle-
dc.identifier.doi10.1080/14767058.2018.1519797-
dc.identifier.isiWOS:000517587800024-
dc.contributor.orcidGyselaers, Wilfried/0000-0002-5778-434X; Smeets,-
dc.contributor.orcidChristophe/0000-0002-1746-7585; Lanssens, Dorien/0000-0003-2442-656X-
dc.identifier.eissn-
dc.identifier.eissn1476-4954-
local.provider.typewosris-
local.uhasselt.uhpubyes-
item.validationecoom 2021-
item.contributorLANSSENS, Dorien-
item.contributorSMEETS, Christophe-
item.contributorVANDERVOORT, Pieter-
item.contributorGRIETEN, Lars-
item.contributorGYSELAERS, Wilfried-
item.accessRightsOpen Access-
item.fullcitationLANSSENS, Dorien; SMEETS, Christophe; VANDERVOORT, Pieter; GRIETEN, Lars & GYSELAERS, Wilfried (2020) Intrathoracic fluid changes from preconception to postpartum as measured by bio-impedance monitoring. In: Journal of Maternal-Fetal & Neonatal Medicine, 33 (9) , p. 1625 -1627.-
item.fulltextWith Fulltext-
crisitem.journal.issn1476-7058-
crisitem.journal.eissn1476-4954-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Manuscript-20180323.pdfPeer-reviewed author version182.75 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

1
checked on Sep 3, 2020

WEB OF SCIENCETM
Citations

3
checked on May 2, 2024

Page view(s)

50
checked on Jul 20, 2022

Download(s)

24
checked on Jul 20, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.