Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/31147
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPattyn, Jade-
dc.contributor.authorPanicker, Gitika-
dc.contributor.authorWillhauck-Fleckenstein, Martina-
dc.contributor.authorVan Keer, Severien-
dc.contributor.authorTeblick, Laura-
dc.contributor.authorPIETERS, Zoe-
dc.contributor.authorTjalma, Wiebren A. A.-
dc.contributor.authorMatheeussen, Veerle-
dc.contributor.authorVan Damme, Pierre-
dc.contributor.authorWaterboer, Tim-
dc.contributor.authorUnger, Elizabeth R.-
dc.contributor.authorVorsters, Alex-
dc.date.accessioned2020-05-19T13:13:37Z-
dc.date.available2020-05-19T13:13:37Z-
dc.date.issued2020-
dc.date.submitted2020-05-19T12:50:08Z-
dc.identifier.citationJOURNAL OF MEDICAL VIROLOGY, 92 (12), p. 3774-3783-
dc.identifier.issn0146-6615-
dc.identifier.urihttp://hdl.handle.net/1942/31147-
dc.description.abstractVaccine-induced human papillomavirus (HPV) antibodies originating from cervicovaginal secretions were recently shown to be detectable in first-void (FV) urine. This presents a novel opportunity for noninvasive sampling to monitor HPV antibody status in women participating in large epidemiological studies and HPV vaccine trials. With a view towards method optimization, this study compared the measurement of HPV antibodies in FV urine using a multiplex L1/L2 virus-like particles (VLP)-based ELISA (M4ELISA) with previously reported results using a glutathione S-transferase (GST)-L1-based immunoassay (GST-L1-MIA). We tested 53 paired FV urine and serum samples from 19- to 26-year-old healthy women, unvaccinated (n = 17) or vaccinated with either the bivalent or quadrivalent HPV-vaccine during adolescence (n = 36). HPV6/11/16/18 antibodies were measured using M4ELISA and compared with GST-L1-MIA results. Inter-assay and inter-specimen correlations were examined using the Spearman's rank test (rs). As expected, lower HPV antibody concentrations were found in FV urine than in serum. Vaccinated women had significantly higher HPV6/11/16/18 antibody levels in both FV urine and serum compared with those unvaccinated (M4ELISA; FV urine P = .0003; serum P <= .0001). HPV antibody levels in FV urine and serum showed a significant positive correlation (M4ELISA anti-HPV6/11/16/18, r(s) = 0.85/0.86/0.91/0.79, P <= .001). Despite assay differences, there was moderate to good correlation between M4ELISA and GST-L1-MIA (FV urine anti-HPV6/11/16/18, r(s) = 0.86/0.83/0.89/0.53, P <= .0001; serum anti-HPV6/11/16/18, r(s) = 0.93/0.89/0.94/0.75, P <= .0001). FV urine HPV antibody detection is comparable with both assays, further supporting this noninvasive sampling method as a possible option for HPV vaccine assessment. Approaches to improve the sensitivity and larger studies are warranted to determine the feasibility of FV urine for vaccine-induced HPV antibody detection.-
dc.description.sponsorshipIndustrial Research Fund of the University of Antwerp, Belgium, Grant/Award Number: PS ID 32387-
dc.language.isoen-
dc.publisherWILEY-
dc.rights2020 The Authors. Journal of Medical Virology published by Wiley Periodicals, In. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in anymedium, provided the original work is properly cited and is not used for commercial purposes.-
dc.subject.otherHPV antibodies-
dc.subject.otherHPV serology-
dc.subject.otherHPV vaccines-
dc.subject.otherhuman papillomavirus-
dc.subject.otherurine-
dc.titleComparison of a VLP‐based and GST‐L1‐based multipleximmunoassay to detect vaccine‐induced HPV‐specificantibodies in first‐void urine-
dc.typeJournal Contribution-
dc.identifier.epage3783-
dc.identifier.issue12-
dc.identifier.spage3774-
dc.identifier.volume92-
local.format.pages10-
local.bibliographicCitation.jcatA1-
dc.description.notesPattyn, J (reprint author), Campus Drie Eiken,Bldg R2,Univ Pl 1, B-12610 Antwerp, Belgium.-
dc.description.notesjade.pattyn@uantwerpen.be-
dc.description.otherPattyn, J (reprint author), Campus Drie Eiken,Bldg R2,Univ Pl 1, B-12610 Antwerp, Belgium. jade.pattyn@uantwerpen.be-
local.publisher.place111 RIVER ST, HOBOKEN 07030-5774, NJ USA-
local.type.refereedRefereed-
local.type.specifiedArticle-
dc.source.typeArticle-
dc.identifier.doi10.1002/jmv.25841-
dc.identifier.pmid32266996-
dc.identifier.isiWOS:000526624900001-
dc.identifier.eissn1096-9071-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.uhasselt.internationalyes-
item.validationecoom 2021-
item.fulltextWith Fulltext-
item.fullcitationPattyn, Jade; Panicker, Gitika; Willhauck-Fleckenstein, Martina; Van Keer, Severien; Teblick, Laura; PIETERS, Zoe; Tjalma, Wiebren A. A.; Matheeussen, Veerle; Van Damme, Pierre; Waterboer, Tim; Unger, Elizabeth R. & Vorsters, Alex (2020) Comparison of a VLP‐based and GST‐L1‐based multipleximmunoassay to detect vaccine‐induced HPV‐specificantibodies in first‐void urine. In: JOURNAL OF MEDICAL VIROLOGY, 92 (12), p. 3774-3783.-
item.accessRightsOpen Access-
item.contributorPattyn, Jade-
item.contributorPanicker, Gitika-
item.contributorWillhauck-Fleckenstein, Martina-
item.contributorVan Keer, Severien-
item.contributorTeblick, Laura-
item.contributorPIETERS, Zoe-
item.contributorTjalma, Wiebren A. A.-
item.contributorMatheeussen, Veerle-
item.contributorVan Damme, Pierre-
item.contributorWaterboer, Tim-
item.contributorUnger, Elizabeth R.-
item.contributorVorsters, Alex-
crisitem.journal.issn0146-6615-
crisitem.journal.eissn1096-9071-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Journal of Medical Virology - 2020 -.pdfPublished version1.61 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

1
checked on Sep 2, 2020

WEB OF SCIENCETM
Citations

8
checked on Jul 10, 2024

Page view(s)

32
checked on Sep 7, 2022

Download(s)

12
checked on Sep 7, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.