Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/31337
Title: Nitric oxide for inhalation in ST-elevation myocardial infarction (NOMI): a multicentre, double-blind, randomized controlled trial
Authors: Janssens, Stefan P.
Bogaert, Jan
Zalewski, Jaroslaw
Toth, Attila
Adriaenssens, Tom
Belmans, Ann
Bennett, Johan
Claus, Piet
Desmet, Walter
Dubois, Christophe
Goetschalckx, Kaatje
Sinnaeve, Peter
Vandenberghe, Katleen
Vermeersch, Pieter
Lux, Arpad
Szelid, Zsolt
Durak, Monika
Lech, Piotr
Zmudka, Krzysztof
Pokreisz, Peter
VRANCKX, Pascal 
Merkely, Bela
Bloch, Kenneth D.
Van de Werf, Frans
Issue Date: 2018
Publisher: OXFORD UNIV PRESS
Source: European heart journal, 39 (29) , p. 2717 -2725
Abstract: Aims Inhalation of nitric oxide (iNO) during myocardial ischaemia and after reperfusion confers cardioprotection in preclinical studies via enhanced cyclic guanosine monophosphate (cGMP) signalling. We tested whether iNO reduces reperfusion injury in patients with ST-elevation myocardial infarction (STEMI; NCT01398384). Methods and results We randomized in a double-blind, placebo-controlled study 250 STEMI patients to inhale oxygen with (iNO) or without (CON) 80 parts-per-million NO for 4 h following percutaneous revascularization. Primary efficacy endpoint was infarct size as a fraction of left ventricular (LV) size (IS/LVmass), assessed by delayed enhancement contrast magnetic resonance imaging (MRI). Pre-specified subgroup analysis included thrombolysis-in-myocardial-infarction flow in the infarct-related artery, troponin T levels on admission, duration of symptoms, location of culprit lesion, and intra-arterial nitroglycerine (NTG) use. Secondary efficacy endpoints included IS relative to risk area (IS/AAR), myocardial salvage index, LV functional recovery, and clinical events at 4 and 12months. In the overall population, IS/LVmass at 48-72 h was 18.0 +/- 13.4% in iNO (n= 109) and 19.4 +/- 15.4% in CON [n= 116, effect size -1.524%, 95% confidence interval (95% CI) -5.28, 2.24; P= 0.427]. Subgroup analysis indicated consistency across clinical confounders of IS but significant treatment interaction with NTG (P= 0.0093) resulting in smaller IS/LVmass after iNO in NTG-naive patients (n= 140, P< 0.05). The secondary endpoint IS/AAR was 53 +/- 26% with iNO vs. 60 +/- 26% in CON (effect size -6.8%, 95% CI -14.8, 1.3, P= 0.09) corresponding to a myocardial salvage index of 47 +/- 26% vs. 40 +/- 26%, respectively, P= 0.09. Cine-MRI showed similar LV volumes at 48-72 h, with a tendency towards smaller increases in end-systolic and end-diastolic volumes at 4 months in iNO (P= 0.048 and P= 0.06, respectively, n= 197). Inhalation of nitric oxide was safe and significantly increased cGMP plasma levels during 4 h reperfusion. The Kaplan-Meier analysis for the composite of death, recurrent ischaemia, stroke, or rehospitalizations showed a tendency toward lower event rates with iNO at 4 months and 1 year (log-rank test P= 0.10 and P= 0.06, respectively). Conclusions Inhalation of NO at 80 ppm for 4 h in STEMI was safe but did not reduce infarct size relative to absolute LVmass at 48-72h. The observed functional recovery and clinical event rates at follow-up and possible interaction with nitroglycerine warrant further studies of iNO in STEMI.
Notes: Janssens, SP (reprint author), Katholieke Univ Leuven, Univ Hosp Leuven, Dept Cardiovasc Dis, Herestr 49, B-3000 Leuven, Belgium.; Janssens, SP (reprint author), Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium.
stefan.janssens@kuleuven.be
Keywords: Myocardial infarction; Cardioprotection; Inhaled nitric oxide; Left;ventricular remodelling; Cyclic guanosine monophosphate; Reperfusion;injury
Document URI: http://hdl.handle.net/1942/31337
ISSN: 0195-668X
e-ISSN: 1522-9645
DOI: 10.1093/eurheartj/ehy232
ISI #: WOS:000441009100010
Category: A1
Type: Journal Contribution
Appears in Collections:Research publications

Files in This Item:
File Description SizeFormat 
ehy232.pdf
  Restricted Access
Published version489.51 kBAdobe PDFView/Open    Request a copy
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.