Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/31339
Title: | Dynamic Visual Acuity test while walking or running on treadmill: Reliability and normative data | Authors: | VERBECQUE, Evi Van Criekinge T Vanloot D Coeckelbergh T Van de Heyning P Hallemans A Vereeck, Luc |
Issue Date: | 2018 | Publisher: | ELSEVIER IRELAND LTD |
Source: | Gait & posture, Gait & posture, 65 , p. 137 -142 | Abstract: | This study aimed to report normative reference data for a Dynamic Visual Acuity test while walking on treadmill. The protocol's suitability was assessed by investigating its test-retest reliability and its validity through the drop-out rate and verification of the frequency of head movements. Furthermore, the influence of age on visual acuity loss (VAL) was determined to reveal the need for age-specific reference data. Background: This study aimed to report normative reference data for a Dynamic Visual Acuity test while walking on treadmill. The protocol's suitability was assessed by investigating its test-retest reliability and its validity through the drop-out rate and verification of the frequency of head movements. Furthermore, the influence of age on visual acuity loss (VAL) was determined to reveal the need for age-specific reference data.Methods: Visual acuity was measured in 171 healthy adult participants (age range: 20.0-77.3 years; mean age: 40.1 years) with the head stationary (SVA) and in a dynamic condition (DVA) while walking on treadmill at 3, 4, 6 and 9 km/h. Relative test-retest reliability on SVA and DVA was investigated with intraclass correlation coefficients (ICC). The measurement errors of SVA, DVA and VAL were calculated for absolute reliability. Influence of age on VAL was investigated with regression analysis, followed by an ANOVA to investigate decade-related differences. The drop-out rate during DVA was mapped using a frequency table. Head frequencies were monitored using 3D motion tracking software.Results: Strong consistency (ICC >= 0.89) was found for SVA and DVA values. Measurement errors for VAL were less than 0.1 logMAR. Younger participants (decade 3-4) showed less VAL at 3 and 4 km/h. The drop-out rate increased with increasing walking speed (0-18.8%), especially in older adults. Although head frequency increased with increasing speed, the dominant frequency ranged around 2 Hz for all walking speeds.Conclusion: This DVA protocol is reliable and normative data have been established. To facilitate its use in clinical practice, further validation of the protocol in patients with bilateral vestibulopathy is needed. |
Keywords: | Ageing;Dynamic visual acuity test;Normative data;Vestibular function test;Adult;Aged;Aged, 80 and over;Cross-Sectional Studies;Exercise Test;Female;Head Movements;Humans;Male;Middle Aged;Reference Values;Reproducibility of Results;Running;Vision Disorders;Visual Acuity;Walking;Walking Speed;Young Adult | Document URI: | http://hdl.handle.net/1942/31339 | Link to publication/dataset: | http://europepmc.org/abstract/med/30558920 | ISSN: | 0966-6362 | e-ISSN: | 1879-2219 | DOI: | 10.1016/j.gaitpost.2018.07.166 | ISI #: | WOS:000441877300023 | Rights: | 2018 Elsevier B.V. All rights reserved. | Category: | A1 | Type: | Journal Contribution |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1-s2.0-S096663621831275X-main.pdf Restricted Access | Published version | 467.69 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.