Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/31473
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | SCHOUTTETEN, Melanie | - |
dc.contributor.author | VRANKEN, Julie | - |
dc.contributor.author | Lee, Seulki | - |
dc.contributor.author | SMEETS, Christophe | - |
dc.contributor.author | DE CANNIERE, Helene | - |
dc.contributor.author | Van Hoof, Chris | - |
dc.contributor.author | PEETERS, Jacques | - |
dc.contributor.author | Groenendaal, Willemijn | - |
dc.contributor.author | VANDERVOORT, Pieter | - |
dc.date.accessioned | 2020-07-27T13:22:12Z | - |
dc.date.available | 2020-07-27T13:22:12Z | - |
dc.date.issued | 2020 | - |
dc.date.submitted | 2020-07-24T12:33:26Z | - |
dc.identifier.citation | BMC nephrology, 21 (1) (Art N° 264) | - |
dc.identifier.issn | 1471-2369 | - |
dc.identifier.uri | http://hdl.handle.net/1942/31473 | - |
dc.description.abstract | Background Haemodialysis (HD) patients are burdened by frequent fluid shifts which amplify their comorbidities. Bioimpedance (bioZ) is a promising technique to monitor changes in fluid status. The aim of this study is to investigate if the thoracic bioZ signal can track fluid changes during a HD session. Methods Prevalent patients from a single centre HD unit were monitored during one to six consecutive HD sessions using a wearable multi-frequency thoracic bioZ device. Ultrafiltration volume (UFV) was determined based on the interdialytic weight gain and target dry weight set by clinicians. The correlation between the bioZ signal and UFV was analysed on population level. Additionally regression models were built and validated per dialysis session. Results 66 patients were included, resulting in a total of 133 HD sessions. Spearman correlation between the thoracic bioZ and UFV showed a significant strong correlation of 0.755 (p < 0.01) on population level. Regression analysis per session revealed a strong relation between the bioZ value and the UFV (R2 = 0.982). The fluid extraction prediction error of the leave-one-out cross validation was very small (56.2 ml [− 121.1–194.1 ml]) across all sessions at all frequencies. Conclusions This study demonstrated that thoracic bioZ is strongly correlated with fluid shifts during HD over a large range of UFVs. Furthermore, leave-one-out cross validation is a step towards personalized fluid monitoring during HD and could contribute to the creation of autonomous dialysis. | - |
dc.language.iso | en | - |
dc.publisher | - | |
dc.rights | © The Author(s). 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. | - |
dc.subject.other | Chronic kidney disease | - |
dc.subject.other | Haemodialysis | - |
dc.subject.other | Thoracic | - |
dc.subject.other | Bioimpedance | - |
dc.subject.other | Fluid change | - |
dc.title | Towards personalized fluid monitoring in haemodialysis patients: thoracic bioimpedance signal shows strong correlation with fluid changes, a cohort study | - |
dc.type | Journal Contribution | - |
dc.identifier.issue | 1 | - |
dc.identifier.volume | 21 | - |
local.bibliographicCitation.jcat | A1 | - |
local.publisher.place | CAMPUS, 4 CRINAN ST, LONDON N1 9XW, ENGLAND | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
local.bibliographicCitation.artnr | 264 | - |
dc.identifier.doi | 10.1186/s12882-020-01922-6 | - |
dc.identifier.pmid | 32652949 | - |
dc.identifier.isi | WOS:000552040700001 | - |
dc.identifier.eissn | - | |
local.provider.type | - | |
local.uhasselt.uhpub | yes | - |
item.fullcitation | SCHOUTTETEN, Melanie; VRANKEN, Julie; Lee, Seulki; SMEETS, Christophe; DE CANNIERE, Helene; Van Hoof, Chris; PEETERS, Jacques; Groenendaal, Willemijn & VANDERVOORT, Pieter (2020) Towards personalized fluid monitoring in haemodialysis patients: thoracic bioimpedance signal shows strong correlation with fluid changes, a cohort study. In: BMC nephrology, 21 (1) (Art N° 264). | - |
item.fulltext | With Fulltext | - |
item.validation | ecoom 2021 | - |
item.contributor | SCHOUTTETEN, Melanie | - |
item.contributor | VRANKEN, Julie | - |
item.contributor | Lee, Seulki | - |
item.contributor | SMEETS, Christophe | - |
item.contributor | DE CANNIERE, Helene | - |
item.contributor | Van Hoof, Chris | - |
item.contributor | PEETERS, Jacques | - |
item.contributor | Groenendaal, Willemijn | - |
item.contributor | VANDERVOORT, Pieter | - |
item.accessRights | Open Access | - |
crisitem.journal.eissn | 1471-2369 | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Schoutteten_et_al-2020-BMC_Nephrology.pdf | Published version | 755.99 kB | Adobe PDF | View/Open |
WEB OF SCIENCETM
Citations
9
checked on May 8, 2024
Page view(s)
50
checked on Jul 20, 2022
Download(s)
30
checked on Jul 20, 2022
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.