Please use this identifier to cite or link to this item: http://hdl.handle.net/1942/31555
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDE CANNIERE, Helene-
dc.contributor.authorSMEETS, Christophe-
dc.contributor.authorSCHOUTTETEN, Melanie-
dc.contributor.authorVaron, Carolina-
dc.contributor.authorVan Huffel, Sabine-
dc.contributor.authorVan Hoof, Chris-
dc.contributor.authorGroenendaal, Willemijn-
dc.contributor.authorVANDERVOORT, Pieter-
dc.date.accessioned2020-08-05T08:14:57Z-
dc.date.available2020-08-05T08:14:57Z-
dc.date.issued2020-
dc.date.submitted2020-07-16T10:01:08Z-
dc.identifier.citationJOURNAL OF MEDICAL INTERNET RESEARCH, 22 (5) (Art N° e17326)-
dc.identifier.urihttp://hdl.handle.net/1942/31555-
dc.description.abstractBackground: Cardiac rehabilitation (CR) is known for its beneficial effects on functional capacity and is a key component within current cardiovascular disease management strategies. In addition, a larger increase in functional capacity is accompanied by better clinical outcomes. However, not all patients respond in a similar way to CR. Therefore, a patient-tailored approach to CR could open up the possibility to achieve an optimal increase in functional capacity in every patient. Before treatment can be optimized, the differences in response of patients in terms of cardiac adaptation to exercise should first be understood. In addition, digital biomarkers to steer CR need to be identified. Objective: The aim of the study was to investigate the difference in cardiac response between patients characterized by a clear improvement in functional capacity and patients showing only a minor improvement following CR therapy. Methods: A total of 129 patients in CR performed a 6-minute walking test (6MWT) at baseline and during four consecutive short-term follow-up tests while being equipped with a wearable electrocardiogram (ECG) device. The 6MWTs were used to evaluate functional capacity. Patients were divided into high- and low-response groups, based on the improvement in functional capacity during the CR program. Commonly used heart rate parameters and cardiac digital biomarkers representative of the heart rate behavior during the 6MWT and their evolution over time were investigated. Results: All participating patients improved in functional capacity throughout the CR program (P<.001). The heart rate parameters, which are commonly used in practice, evolved differently for both groups throughout CR. The peak heart rate (HRpeak) from patients in the high-response group increased significantly throughout CR, while no change was observed in the low-response group (F-4.92 =8.321, p <.001). Similar results were obtained for the recovery heart rate (HRrec) values, which increased significantly over time during every minute of recuperation, for the high-response group (HRrec1 : p < .001, HRrec2 : P<.001, HRrec3: P<.001, HRrec4: p <.001, and HRrec5 : P=.02). The other digital biomarkers showed that the evolution of heart rate behavior during a standardized activity test differed throughout CR between both groups. These digital biomarkers, derived from the continuous measurements, contribute to more in-depth insight into the progression of patients' cardiac responses. Conclusions: This study showed that when using wearable sensor technology, the differences in response of patients to CR can be characterized by means of commonly used heart rate parameters and digital biomarkers that are representative of cardiac response to exercise. These digital biomarkers, derived by innovative analysis techniques, allow for more in-depth insights into the cardiac response of cardiac patients during standardized activity. These results open up the possibility to optimized and more patient-tailored treatment strategies and to potentially improve CR outcome.-
dc.description.sponsorshipThis report is part of the Limburg Clinical Research Program (LCRP), Hasselt University (UHasselt)-Ziekenhuis Oost-Limburg (ZOL)-Jessa, supported by the foundation Limburg Sterk Merk (LSM), province of Limburg, Flemish government, UHasselt, ZOL, and Jessa Hospital. We would like to thank the engineers from Holst Centre, imec the Netherlands, for their technical support. We thank the physiotherapists from the cardiac rehabilitation center, ZOL, for their support and guidance during the study. HDC is supported by a doctoral fellowship by the Research Foundation, Flanders (FWO), Belgium (grant number: 1S53616N). SVH is supported by the Flemish Government under the Onderzoeksprogramma Artificiele Intelligentie Vlaanderen program. SVH and CV's research is supported by Agentschap Innoveren en Ondernemen (VLAIO) (150466-OSA+) and imec funds 2017.-
dc.language.isoen-
dc.publisherJMIR PUBLICATIONS, INC-
dc.rightsThis is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.-
dc.subject.otherwearables-
dc.subject.othersensor-
dc.subject.other6MWT-
dc.subject.otherrehabilitation-
dc.subject.othercardiovascular-
dc.titleUsing Biosensors and Digital Biomarkers to Assess Response to Cardiac Rehabilitation: Observational Study-
dc.typeJournal Contribution-
dc.identifier.issue5-
dc.identifier.volume22-
local.format.pages14-
local.bibliographicCitation.jcatA1-
dc.description.notesDe Canniere, H (corresponding author), Hasselt Univ UHasselt, Fac Med & Life Sci, Limburg Clin Res Ctr LCRC, Mobile Hlth Unit, B-3590 Diepenbeek, Belgium.-
dc.description.noteshelene.decanniere@uhasselt.be-
dc.description.otherDe Canniere, H (corresponding author), Hasselt Univ UHasselt, Fac Med & Life Sci, Limburg Clin Res Ctr LCRC, Mobile Hlth Unit, B-3590 Diepenbeek, Belgium. helene.decanniere@uhasselt.be-
local.publisher.place130 QUEENS QUAY E, STE 1102, TORONTO, ON M5A 0P6, CANADA-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnre17326-
dc.identifier.doi10.2196/17326-
dc.identifier.pmid32432552-
dc.identifier.isiWOS:000534153700001-
dc.contributor.orcidSmeets, Christophe/0000-0002-1746-7585; Varon,-
dc.contributor.orcidCarolina/0000-0002-9581-0676; Van Huffel, Sabine/0000-0001-5939-0996; De-
dc.contributor.orcidCanniere, Helene/0000-0002-7681-3011-
dc.identifier.eissn-
local.provider.typewosris-
local.uhasselt.uhpubyes-
local.description.affiliation[De Canniere, Helene; Smeets, Christophe J. P.; Schoutteten, Melanie; Vandervoort, Pieter] Hasselt Univ UHasselt, Fac Med & Life Sci, Limburg Clin Res Ctr LCRC, Mobile Hlth Unit, B-3590 Diepenbeek, Belgium.-
local.description.affiliation[De Canniere, Helene; Smeets, Christophe J. P.; Schoutteten, Melanie; Vandervoort, Pieter] Ziekenhuis Oost Limburg, Dept Future Hlth, Genk, Belgium.-
local.description.affiliation[Smeets, Christophe J. P.; Groenendaal, Willemijn] Imec Netherlands, Holst Ctr, Eindhoven, Netherlands.-
local.description.affiliation[Varon, Carolina; Van Hoof, Chris; Van Huffel, Sabine] KU Katholieke Univ Leuven, Dept Elect Engn ESAT, Signal Proc & Data Analyt STADIUS, Ctr Dynam Syst, Leuven, Belgium.-
local.description.affiliation[Varon, Carolina] Delft Univ Technol TU Delft, Dept Microelect, Circuits & Syst CAS, Delft, Netherlands.-
local.description.affiliation[Van Hoof, Chris] Imec Vzw Belgium, Leuven, Belgium.-
local.description.affiliation[Vandervoort, Pieter] Ziekenhuis Oost Limburg, Dept Cardiol, Genk, Belgium.-
item.contributorDE CANNIERE, Helene-
item.contributorSMEETS, Christophe-
item.contributorSCHOUTTETEN, Melanie-
item.contributorVaron, Carolina-
item.contributorVan Huffel, Sabine-
item.contributorVan Hoof, Chris-
item.contributorGroenendaal, Willemijn-
item.contributorVANDERVOORT, Pieter-
item.validationecoom 2021-
item.fullcitationDE CANNIERE, Helene; SMEETS, Christophe; SCHOUTTETEN, Melanie; Varon, Carolina; Van Huffel, Sabine; Van Hoof, Chris; Groenendaal, Willemijn & VANDERVOORT, Pieter (2020) Using Biosensors and Digital Biomarkers to Assess Response to Cardiac Rehabilitation: Observational Study. In: JOURNAL OF MEDICAL INTERNET RESEARCH, 22 (5) (Art N° e17326).-
item.accessRightsOpen Access-
item.fulltextWith Fulltext-
crisitem.journal.issn1438-8871-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
helene.pdfPublished version717.91 kBAdobe PDFView/Open
Show simple item record

WEB OF SCIENCETM
Citations

8
checked on Apr 22, 2024

Page view(s)

40
checked on Jul 20, 2022

Download(s)

26
checked on Jul 20, 2022

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.