Please use this identifier to cite or link to this item:
http://hdl.handle.net/1942/31905
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | GOUVEIA HENRIQUES, Jose | - |
dc.contributor.author | Jaspart, J-P. | - |
dc.contributor.author | Silva, L. Simões da | - |
dc.date.accessioned | 2020-09-16T09:38:52Z | - |
dc.date.available | 2020-09-16T09:38:52Z | - |
dc.date.issued | 2014 | - |
dc.date.submitted | 2020-09-11T11:16:02Z | - |
dc.identifier.citation | Advanced Steel Construction, 10 (1) , p. 33 -52 | - |
dc.identifier.issn | 1816-112X | - |
dc.identifier.uri | http://hdl.handle.net/1942/31905 | - |
dc.description.abstract | The resistance of bolted lap shear connections in bearing is traditionally evaluated by considering an equal distribution of internal forces amongst the bolts. In fact, such an assumption may only be seen as the result of a plastic redistribution of the internal forces, what requires shear ductility in the vicinity of the bolts. In the present paper, ductility requirements are proposed that ensure that, in the presence of real geometric imperfections, plastic resistance can be attained. | - |
dc.description.sponsorship | For sharing their experimental data, the authors would like to express their thanks to Delft University of Technology in the name of Prof. F. S. K. Bijlaard and to University of Ljubljana in the name of Prof. Darko Beg. Concerning the use of LAGAMINE code, a word of gratitude should be said to the “LAGAMINE Group” of ArGEnCo Department of the University of Liège. Finally, Mr. Piraprez is acknowledged for sharing his knowledge and documents. | - |
dc.language.iso | en | - |
dc.publisher | - | |
dc.subject.other | Shear bolted connections | - |
dc.subject.other | equivalent bolt zone component | - |
dc.subject.other | available deformation capacity | - |
dc.subject.other | required deformation capacity | - |
dc.subject.other | ductility criteria | - |
dc.title | Ductility requirements for the design of bolted lap shear connections in bearing | - |
dc.type | Journal Contribution | - |
dc.identifier.epage | 52 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 33 | - |
dc.identifier.volume | 10 | - |
local.format.pages | 20 | - |
local.bibliographicCitation.jcat | A1 | - |
local.type.refereed | Refereed | - |
local.type.specified | Article | - |
dc.identifier.doi | 10.18057/IJASC.2014.10.1.3 | - |
dc.identifier.eissn | - | |
local.provider.type | CrossRef | - |
local.uhasselt.uhpub | no | - |
item.fulltext | With Fulltext | - |
item.fullcitation | GOUVEIA HENRIQUES, Jose; Jaspart, J-P. & Silva, L. Simões da (2014) Ductility requirements for the design of bolted lap shear connections in bearing. In: Advanced Steel Construction, 10 (1) , p. 33 -52. | - |
item.contributor | GOUVEIA HENRIQUES, Jose | - |
item.contributor | Jaspart, J-P. | - |
item.contributor | Silva, L. Simões da | - |
item.accessRights | Restricted Access | - |
crisitem.journal.issn | 1816-112X | - |
Appears in Collections: | Research publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Microsoft Word - 3-12-177-pp33-52_JoseHenriques-Revision.doc.pdf Restricted Access | Published version | 633.36 kB | Adobe PDF | View/Open Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.