dc.date.submitted2020-10-19T07:08:50Z-
dc.identifier.citationPhysics in medicine and biology (Print),65(23) (Art N° 235010)-
dc.identifier.issn0031-9155-
dc.identifier.urihttp://hdl.handle.net/1942/32538-
dc.description.abstractAn improved biological weighting function (IBWF) is proposed to phenomenologically relate microdosimetric lineal energy probability density distributions with the relative biological effectiveness (RBE) for the in vitro clonogenic cell survival (surviving fraction = 10%) of the most commonly used mammalian cell line, i.e. the Chinese hamster lung fibroblasts (V79). The IBWF, intended as a simple and robust tool for a fast RBE assessment to compare different exposure conditions in particle therapy beams, was determined through an iterative global-fitting process aimed to minimize the average relative deviation between RBE calculations and literature in vitro data in case of exposure to various types of ions from H-1 to U-238. By using a single particle- and energy- independent function, it was possible to establish an univocal correlation between lineal energy and clonogenic cell survival for particles spanning over an unrestricted linear energy transfer range of almost five orders of magnitude (0.2 keV mu m(-1) to 15 000 keV mu m(-1) in liquid water). The average deviation between IBWF-derived RBE values and the published in vitro data was similar to 14%. The IBWF results were also compared with corresponding calculations (in vitro RBE10 for the V79 cell line) performed using the modified microdosimetric kinetic model (modified MKM). Furthermore, RBE values computed with the reference biological weighting function (BWF) for the in vivo early intestine tolerance in mice were included for comparison and to further explore potential correlations between the BWF results and the in vitro RBE as reported in previous studies. The results suggest that the modified MKM possess limitations in reproducing the experimental in vitro RBE10 for the V79 cell line in case of ions heavier than Ne-20. Furthermore, due to the different modelled endpoint, marked deviations were found between the RBE values assessed using the reference BWF and the IBWF for ions heavier than H-2. Finally, the IBWF was unchangingly applied to calculate RBE values by processing lineal energy density distributions experimentally measured with eight different microdosimeters in 19 H-1 and C-12 beams at ten different facilities (eight clinical and two research ones). Despite the differences between the detectors, irradiation facilities, beam profiles (pristine or spread out Bragg peak), maximum beam energy, beam delivery (passive or active scanning), energy degradation system (water, PMMA, polyamide or low-density polyethylene), the obtained IBWF-based RBE trends were found to be in good agreement with the corresponding ones in case of computer-simulated microdosimetric spectra (average relative deviation equal to 0.8% and 5.7% for H-1 and C-12 ions respectively).-
dc.description.sponsorshipAP is very thankful to Thomas Friedrich for providing him access to the PIDE database and to the Research Foundation—Flanders (FWO) for the ‘Short stay outside Europe’ grant to partly cover the expenses of his stay in Japan. AP thanks Shuichi Tsuda (Japan Atomic Energy Agency, Japan—currently at Nuclear Energy Agency, France), Davide Mazzucconi, Davide Bortot and Stefano Agosteo (Polytech of Milano, Italy) and Andreas Tefre Samnøy (University of Bergen, Norway) for sharing a digital copy of the microdosimetric spectra gathered with respectively the wall-less TEPC, the avalanche-confinement TEPC and the MicroPlus Mushroom at OCL. AB thanks Anna Selva, Valeria Conte and Paolo Colautti (INFN LNL, Italy) for sharing a digital copy of the mini-TEPC microdosimetric spectra.-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.rights2020 Institute of Physics and Engineering in Medicine-
dc.subject.otherbiophysical modeling-
dc.subject.otherrelative biological effectiveness-
dc.subject.othermicrodosimetry-
dc.subject.otherradiobiological weighting function-
dc.subject.othermicrodosimetric kinetic model-
dc.subject.otherPHITS-
dc.titleDevelopment of a new microdosimetric biological weighting function for the RBE10 assessment in case of the V79 cell line exposed to ions from 1H to 238U-
dc.typeJournal Contribution-
dc.identifier.issue23-
dc.identifier.volume65-
local.format.pages21-
local.bibliographicCitation.jcatA1-
local.publisher.placeTEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND-
local.type.refereedRefereed-
local.type.specifiedArticle-
local.bibliographicCitation.artnr235010-
dc.identifier.doi10.1088/1361-6560/abbf96-
dc.identifier.isi000595507000001-
local.provider.typeCrossRef-
local.uhasselt.uhpubyes-
local.uhasselt.internationalyes-
item.accessRightsOpen Access-
item.contributorParisi, Alessio-
item.contributorSato, Tatsuhiko-
item.contributorMatsuya, Yusuke-
item.contributorKase, Yuki-
item.contributorMagrin, Giulio-
item.contributorVerona, Claudio-
item.contributorTran , Linh T-
item.contributorRosenfeld, Anatoly B-
item.contributorBIANCHI, Anna-
item.contributorOlko, Pawel-
item.contributorStruelens, Lara-
item.contributorVanhavere, Filip-
item.fullcitationParisi, Alessio; Sato, Tatsuhiko; Matsuya, Yusuke; Kase, Yuki; Magrin, Giulio; Verona, Claudio; Tran , Linh T; Rosenfeld, Anatoly B; BIANCHI, Anna; Olko, Pawel; Struelens, Lara & Vanhavere, Filip (2020) Development of a new microdosimetric biological weighting function for the RBE10 assessment in case of the V79 cell line exposed to ions from 1H to 238U. In: Physics in medicine and biology (Print),65(23) (Art N° 235010).-
item.fulltextWith Fulltext-
crisitem.journal.issn0031-9155-
crisitem.journal.eissn1361-6560-
Appears in Collections:Research publications
Files in This Item:
File Description SizeFormat 
Parisi_2020_Phys._Med._Biol._65_235010.pdf
  Restricted Access
Published version2.11 MBAdobe PDFView/Open    Request a copy
Parisi+et+al_2020_Phys._Med._Biol._10.1088_1361-6560_abbf96.pdfPeer-reviewed author version2.56 MBAdobe PDFView/Open
Show simple item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.